Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Tongue Interlock Switches > Cadet™ 3
Cadet™ 3
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions—mm (inches) | Typical Wiring Diagrams |
| Contact | Actuator Type | Cat. No. | |||||
| Safety | Auxiliary | Action | M16 Conduit | Connector§ | |||
| M16 | 1/2 inch NPT Adaptor | Connect to Distribution Box 6-Pin Micro (M12) |
Connect to ArmorBlock Guard I/O 5-Pin Micro (M12)§ |
||||
| 3 N.C. | — | — | Flat | 440K-C21096 | 440K-C21048 | 440K-C21090 | 440K-C2NNFPS |
| 90° | 440K-C21097 | 440K-C21057 | 440K-C21091 | — | |||
| GD2 Metal Alignment Guide with Semi-Flex Actuator | — | 440K-C21062 | 440K-C21092 | 440K-C2NNAPS | |||
| — | 440K-C21070 | — | — | — | |||
| 2 N.C. | 1 N.O. | BBM | Flat | 440K-C21098 | 440K-C21050 | 440K-C21054 | — |
| 90° | 440K-C21061 | 440K-C21058 | 440K-C21067 | — | |||
| GD2 Metal alignment guide w/semi-flex actuator | — | 440K-C21074 | 440K-C21088 | — | |||
| — | 440K-C21055 | — | — | — | |||
| MBB | Flat | 440K-C21052 | 440K-C21093 | 440K-C21060 | — | ||
| 90° | 440K-C21065 | 440K-C21094 | 440K-C21068 | — | |||
| GD2 Metal Alignment Guide with Semi-Flex Actuator | — | 440K-C21095 | 440K-C21089 | — | |||
| — | 440K-C21080 | — | — | — | |||
§ For connector ratings see Safety Switches and Connectors.
§ With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 6-Pin Micro (M12) | 5-Pin Micro (M12) |
| Cordset | 889R-F6ECA-¬ | — |
| Patchcord | 889R-F6ECRM-T | 889R-F5ECRM-¬ |
| Distribution Box | 898R-P68MT-A5 | — |
| Shorting Plug | 898R-P61MU-RM | — |
| T-Port | NA | — |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.