Trojan™ T15

Click to enlarge - 440K-T11##(T15)_Product


Description

The Trojan T15 is a compact universal tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. With its dual entry slots and rotatable head, movable only by releasing the cover screws, the Trojan T15 can offer four different options for actuator entry.

The Trojan T15 features a compact housing, only 75 x 52 x 32 mm (2.95 x 2.04 x 1.25 in.) and includes direct opening action contacts and a tamper-resistant mechanism. The Trojan T15 has 2 N.C. safety contacts or 1 N.C. safety contact and 1 N.O. auxiliary contact. The unit is sealed to IP67 and has three M20 conduit entries.

Operation of the switch is achieved by the insertion of the specially-profiled stainless-steel actuator which should be permanently fixed to the leading edge of the guard door. The standard T15 incorporates actuator retention force of 30N. An optional catch mechanism helps keep doors shut on vibrating machinery.


Features


Specifications

Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 device per EN 954-1 dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety
B10d: > 2 x 106 operations at min. load
PFHD: > 3 x10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives, cULus, TÜV, and CCC
Outputs
Safety Contacts T 
Direct Opening Action
2 N.C. 1 N.C.
Auxiliary Contacts None 1 N.O.
Thermal CurrentIlth 10 A
Rated Insulation Voltage (Ui) 500V
Switching Current @ Voltage, Min. 5 mA @ 5V DC
Utilization Category
A600/AC-15 (Ue) (Ue) 600V 500V 240V 120V
(le) (le) 1.2 A 1.4 A 3.0 A 6.0 A
DC-13 (Ue) (Ue) 24V      
(le) (le) 2 A      
Operating Characteristics
Break Contact Force, Min. 30 N (6.70 lbf)
Actuation Speed, Max. 160 mm (6.29 in.)/s
Actuation Frequency, Max. 2 cycles/s
Operating Radius, Min 175 mm (6.89 in.) [60 mm (2.36 in.) with flexible actuator]
Operating Life @ 100 mA load 1 x 106 operations
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -20…+80° (-4…+176°)
Physical Characteristics
Housing Material UL Approved glass-filled PBT
Actuator Material Stainless Steel
Weight [g (lb)] 120 (0.265)
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years
T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started.

Product Selection

Type Contact Contact Action Actuator Type Cat. No.
M20 Conduit Connector§ 
Safety Auxiliary M20 1/2 inch NPT Adaptor Connect to Distribution Box
4-Pin Micro (M12)
Connect to ArmorBlock Guard I/O
5-Pin Micro (M12)
Trojan T15 Standard 2 N.C. Standard 440K-T11303 440K-T11267 440K-T11307 440K-V2NNSPS
Fully-Flex 440K-T11395 440K-T11273 440K-T11384 440K-V2NNBPS
440K-T11269 440K-T11385
1 N.C. 1 N.O. BBM Standard 440K-T11305 440K-T11268 440K-T11386
Fully-Flex 440K-T11396 440K-T11276 440K-T11387
440K-T11270 440K-T11388
Trojan T15 GD2 2 N.C. GD2 Standard 440K-T11463 440K-T11288 440K-T11389 440K-V2NNGPS-NG
Fully-Flex 440K-T11397 440K-T11287 440K-T11390
440K-T11280 440K-T11391
1 N.C. 1 N.O. BBM GD2 Standard 440K-T11398 440K-T11284 440K-T11392
Fully-Flex 440K-T11399 440K-T11283 440K-T11393
440K-T11279 440K-T11394
 

§ For connector ratings see Safety Switches and Connectors.


Recommended Logic Interfaces

Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays for 2 N.C. Contact Switch
MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC MSR127RP/TP 440R-N23135
MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC MSR127RP/TP 440R-N23132
MSR30RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC MSR30RT/RTP 440R-N23198
Single-Function Safety Relays for 1 N.C. & 1 N.O. Contact Switch
MSR9T 2 N.O. 1 N.C. Fixed Auto./Manual 24V AC/DC MSR9T 440R-F23027
MSR33RT 2 N.O. Solid State 1 N.O. Removable Auto. or Monitored Manual 24V DC SELV MSR33RT/RTP 440R-F23200
Modular Safety Relays
MSR210P Base
2 N.C. only
2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit MSR210P 440R-H23176
MSR220P Input Module Removable 24V DC MSR220P 440R-H23178
MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC MSR310P 440R-W23219
MSR320P Input Module 2 PNP Solid State Removable 24V DC from the base unit MSR320P 440R-W23218
  

Note:  For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.


Connection Systems

Description Connection to Distribution Box
4-Pin Micro (M12)
Connection to ArmorBlock Guard I/O
5-Pin Micro (M12)
2 N.C. 1 N.C. & 1 N.O. 2 N.C.
Cordset 889D-F4AC-¬  889D-F4AC-¬ 
Patchcord 889D-F4ACDM-T  889D-F4ACDM-T  889D-F5ACDM-¬ 
Distribution Box 898D-4‡ LT-DM4 898D-P4‡ KT-DM4
Shorting Plug 898D-41LU-DM 898D-41KU-DM
T-Port 898D-43LY-D4 898D-43KY-D4
 

¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
‡ Replace symbol with 4 or 8 for number of ports.
Note:  For additional information, see Safety Connection Systems.


Accessories

Description To Be Used With: Dimensions Cat. No.
Click to enlarge - 440G-A11238_Accessory_Actuator Standard actuator Trojan T15 Standard Models Only Actuators¬  (continued) 440K-A11238
Click to enlarge - 440G-A27011_Accessory_Actuator_GS GD2 standard actuator Trojan GD2 Models Only Actuators¬  440G-A27011
Click to enlarge - 440K_A11112 Actuator_GS GD2 flat actuator Trojan GD2 Models Only Actuators¬  (continued) 440K-A11112
Click to enlarge - 440K_A11144 ActGuide_GS Alignment guide with semi-flexible actuator Discard Alignment Guide for GD2 Models 440K-A11144
Click to enlarge - 440K_A27010 Guide_GS Alignment guide with fully-flexible actuator Discard Alignment Guide for GD2 Models Actuators¬  (continued) 440K-A27010
Click to enlarge - 440G-A27163_Accessory_Actuator_GS Sliding bolt actuator Trojan GD2 Models Only Door Handles 440G-A27163
Click to enlarge - 440K_A11094_Actuator_GS Catch and Retainer Kit Trojan T15 Standard Models Only Actuators¬  440K-A11094
Click to enlarge - 440A-A11499_(T15 GD2 Cover Plate)_Accessory_GS Replacement Cover All Models 440A-A11499
Click to enlarge - 440K_A17180 Dust Cover_GS Dust Cover All Models 440K-A17180
 

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440K-T11##(T15)_Dims


Note: 2D, 3D and electrical drawings are available on www.ab.com.


Typical Wiring Diagrams

Description 1 N.C. & 1 N.O. 2 N.C.
Contact Configuration Click to enlarge - 440K-T11##(T15 1NC-1NO)_Wiring Click to enlarge - 440K-T11##(T15 2NC)_Wiring
Contact Action Click to enlarge - 440K-T11##_(T15 1NO1NC BBM)_Contact Click to enlarge - 440K-T11##_(T15 2NC)_Contact
Click to enlarge - ContactActionKey BBM
4-Pin Micro (M12) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out A (Safety) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out B (Safety)
5-Pin Micro (M12)
For ArmorBlock Guard I/O
Click to enlarge - DC Micro (2-5)-Pin Male A_Pin-out (Safety)
Cordset
889D-F4AC-¬ 
Brown Safety A Safety A
Blue
White Aux A Safety B
Black
 
¬ Replace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths.