Tongue Interlock Switches

Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Tongue Interlock Switches > Trojan™ T15

Trojan™ T15

Introduction Specifications Product Selection Accessories Approximate Dimensions Typical Wiring Diagrams
Specifications

Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 device per EN 954-1 dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety
B10d: > 2 x 106 operations at min. load
PFHD: > 3 x10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives, cULus, TÜV, and CCC
Outputs
Safety Contacts T 
Direct Opening Action
2 N.C. 1 N.C.
Auxiliary Contacts None 1 N.O.
Thermal CurrentIlth 10 A
Rated Insulation Voltage (Ui) 500V
Switching Current @ Voltage, Min. 5 mA @ 5V DC
Utilization Category
A600/AC-15 (Ue) (Ue) 600V 500V 240V 120V
(le) (le) 1.2 A 1.4 A 3.0 A 6.0 A
DC-13 (Ue) (Ue) 24V      
(le) (le) 2 A      
Operating Characteristics
Break Contact Force, Min. 30 N (6.70 lbf)
Actuation Speed, Max. 160 mm (6.29 in.)/s
Actuation Frequency, Max. 2 cycles/s
Operating Radius, Min 175 mm (6.89 in.) [60 mm (2.36 in.) with flexible actuator]
Operating Life @ 100 mA load 1 x 106 operations
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -20…+80° (-4…+176°)
Physical Characteristics
Housing Material UL Approved glass-filled PBT
Actuator Material Stainless Steel
Weight [g (lb)] 120 (0.265)
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years
T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started.