Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Tongue Interlock Switches > Trojan™ T15
Trojan™ T15
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions | Typical Wiring Diagrams |
| Type | Contact | Contact Action | Actuator Type | Cat. No. | ||||
| M20 Conduit | Connector§ | |||||||
| Safety | Auxiliary | M20 | 1/2 inch NPT Adaptor | Connect to Distribution Box 4-Pin Micro (M12) |
Connect to ArmorBlock Guard I/O 5-Pin Micro (M12) |
|||
| Trojan T15 Standard | 2 N.C. | — | — | Standard | 440K-T11303 | 440K-T11267 | 440K-T11307 | 440K-V2NNSPS |
| Fully-Flex | 440K-T11395 | 440K-T11273 | 440K-T11384 | 440K-V2NNBPS | ||||
| — | 440K-T11269 | — | 440K-T11385 | — | ||||
| 1 N.C. | 1 N.O. | BBM | Standard | 440K-T11305 | 440K-T11268 | 440K-T11386 | — | |
| Fully-Flex | 440K-T11396 | 440K-T11276 | 440K-T11387 | — | ||||
| — | 440K-T11270 | — | 440K-T11388 | — | ||||
| Trojan T15 GD2 | 2 N.C. | — | — | GD2 Standard | 440K-T11463 | 440K-T11288 | 440K-T11389 | 440K-V2NNGPS-NG |
| Fully-Flex | 440K-T11397 | 440K-T11287 | 440K-T11390 | — | ||||
| — | 440K-T11280 | — | 440K-T11391 | — | ||||
| 1 N.C. | 1 N.O. | BBM | GD2 Standard | 440K-T11398 | 440K-T11284 | 440K-T11392 | — | |
| Fully-Flex | 440K-T11399 | 440K-T11283 | 440K-T11393 | — | ||||
| — | 440K-T11279 | — | 440K-T11394 | — | ||||
§ For connector ratings see Safety Switches and Connectors.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays for 2 N.C. Contact Switch | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Single-Function Safety Relays for 1 N.C. & 1 N.O. Contact Switch | |||||||
| MSR9T | 2 N.O. | 1 N.C. | Fixed | Auto./Manual | 24V AC/DC | MSR9T | 440R-F23027 |
| MSR33RT | 2 N.O. Solid State | 1 N.O. | Removable | Auto. or Monitored Manual | 24V DC SELV | MSR33RT/RTP | 440R-F23200 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | Connection to Distribution Box 4-Pin Micro (M12) |
Connection to ArmorBlock Guard I/O 5-Pin Micro (M12) |
|
| 2 N.C. | 1 N.C. & 1 N.O. | 2 N.C. | |
| Cordset | 889D-F4AC-¬ | 889D-F4AC-¬ | — |
| Patchcord | 889D-F4ACDM-T | 889D-F4ACDM-T | 889D-F5ACDM-¬ |
| Distribution Box | 898D-4 LT-DM4 | 898D-P4 KT-DM4 | — |
| Shorting Plug | 898D-41LU-DM | 898D-41KU-DM | — |
| T-Port | 898D-43LY-D4 | 898D-43KY-D4 | — |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 4 or 8 for number of ports.
Note: For additional information, see Safety Connection Systems.