Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Tongue Interlock Switches > Trojan 5 & 6
Trojan 5 & 6
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions | Typical Wiring Diagrams |
| Type | Contact | Actuator Type | Cat. No. | |||||
| M20 Conduit | Connector§ | |||||||
| Safety | Auxiliary | Action | M20 | 1/2 inch NPT Adaptor | Connect to Distribution Box 6-Pin Micro (M12) |
Connect to ArmorBlock Guard I/O 5-Pin Micro (M12)§ |
||
| Trojan 5 Standard | 2 N.C. | 1 N.O. | BBM | Standard | 440K-T11090 | 440K-T11202 | 440K-T11205 | — |
| Guide/Semi-Flex | 440K-T11110 | 440K-T11203 | 440K-T11206 | — | ||||
| Guide/Fully-Flex | 440K-T11467 | 440K-T11204 | 440K-T11207 | 440K-T2NNBPS | ||||
| — | 440K-T11089 | — | 440K-T11129 | — | ||||
| BBM Gold Contacts | Standard | 440K-T11085 | — | — | — | |||
| MBB | Standard | 440K-T11118 | 440K-T11208 | 440K-T11224 | — | |||
| Guide/Semi-Flex | 440K-T11123 | 440K-T11209 | 440K-T11363 | — | ||||
| Guide/Fully-Flex | 440K-T11468 | 440K-T11210 | 440K-T11364 | — | ||||
| — | 440K-T11146 | 440K-T11469 | 440K-T11365 | — | ||||
| Trojan 5 GD2 | BBM | GD2 Standard | 440K-T11336 | 440K-T11211 | 440K-T11366 | 440K-T2NNGPS-NG | ||
| Guide/Semi-Flex | 440K-T11337 | 440K-T11212 | 440K-T11367 | — | ||||
| Guide/Fully-Flex | 440K-T11338 | 440K-T11213 | 440K-T11368 | — | ||||
| — | 440K-T11147 | — | 440K-T11226 | — | ||||
| MBB | GD2 Standard | 440K-T11339 | 440K-T11470 | 440K-T11369 | — | |||
| Guide/Semi-Flex | 440K-T11340 | 440K-T11471 | 440K-T11370 | — | ||||
| Guide/Fully-Flex | 440K-T11341 | 440K-T11472 | 440K-T11371 | — | ||||
| — | 440K-T11167 | — | 440K-T11372 | — | ||||
| Trojan 5 30 N | BBM | Standard | 440K-T11333 | 440K-T91024 | 440K-T11492 | — | ||
§ For connector ratings see Safety Switches and Connectors.
§ With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
| Type | Contact | Actuator Type | Cat. No. | ||||
| M20 Conduit | Connector§ | ||||||
| Safety | Auxiliary | Action | M20 | 1/2 inch NPT Adaptor | 8-Pin Micro (M12)§ | ||
| Trojan 6 | 3 N.C. | 1 N.O. | BBM | Standard | 440K-T11171 | 440K-T11435 | — |
| — | 440K-T11449 | 440K-T11408 | — | ||||
| 2 N.C. | 2 N.O. | BBM | Standard | 440K-T11174 | 440K-T11438 | — | |
| — | 440K-T11452 | 440K-T11416 | 440K-W21BNPH | ||||
| MBB | — | 440K-T11453 | 440K-T11454 | 440K-W21MNPH | |||
| Trojan 6 GD2 | 3 N.C. | 1 N.O. | BBM | GD2 Standard | 440K-T11418 | 440K-T11466 | — |
| — | 440K-T11188 | 440K-T11444 | — | ||||
| MBB | — | 440K-T11456 | 440K-T11457 | — | |||
| 2 N.C. | 2 N.O. | BBM | GD2 Standard | 440K-T11445 | 440K-T11425 | — | |
| — | 440K-T11459 | 440K-T11433 | 440K-W21BNPH-NG | ||||
| MBB | — | 440K-T11460 | 440K-T11461 | 440K-W21MNPH-NG | |||
§ For connector ratings see Safety Switches and Connectors.
§ With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | Trojan 5 | Trojan 6 | |
| 5-Pin Micro (M12) | 6-Pin Micro (M12) | 8-Pin Micro (M12) | |
| Cordset | — | 889R-F6ECA-¬ | 889D-F8AB-¬ |
| Patchcord | 889D-F5ACDM-¬ | 889R-F6ECRM-T | 889D-F8ABDM-T |
| Distribution Box | — | 898R-F68MT-A5 | — |
| Shorting Plug | — | 898R-P61MU-RM | — |
| T-Port | — | — | — |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 4 or 8 for number of ports.
Note: For additional information, see Safety Connection Systems.