440G-MT
|
|
Description
The 440G-MT solenoid switch is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated while the guard is open. The guard may only be opened when a signal is applied to the internal solenoid which releases the lock mechanism. The 440G-MT locking mechanism is designed to withstand forces up to 1600 N (360 lb) and the die-cast alloy housing is ideal for use in harsh environments.
The 440G-MT solenoid switch is designed for machines that do not stop immediately or where premature interruption of the machine could cause damage to tooling and components or cause an additional hazard.
A 24V DC enhanced version is available with diagnostic output, which may be used by a control system to indicate whether a guard door is open or shut independently of the lock mechanism status. A built in LED further visually indicates the status of the switch as door open, door shut and unlocked, and door shut and locked.
This enhanced version is supplied with a metal manual override key to more easily enable manual unlocking in conditions when power is not available to electrically unlock the switch.
Features
- Mechanical lock
- High locking force—1600 N (360 lb)
- Heavy-duty die-cast alloy housing, ideal for harsh environments
- Diagnostic version available
Specifications
| Safety Ratings | ||||||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 | |||||
| Safety Classification | Cat. 1 Device per EN954-1 May be suitable for use in Cat 3 or Cat 4 systems depending on the architecture and application characteristics |
|||||
| Functional Safety Data (related to Safety Contacts) ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. load PFHD: < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
|||||
| Certifications | CE Marked for all applicable directives, cULus, TÜV, and CCC | |||||
| Outputs | ||||||
| Safety Contacts T | 3 N.C. or 2 N.C. direct opening action | |||||
| Auxiliary Contacts | 1 N.O. or 2 N.O. | |||||
| Thermal CurrentIlth | 10 A | |||||
| Rated Insulation Voltage | (Ui) 500V | |||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | |||||
| Utilization Category | ||||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V | |
| (le) | 1.2 A | 1.4 A | 3 A | 6 A | ||
| DC-13 | (Ue) | 24V | ||||
| (le) | 2 A | |||||
| Solenoid Characteristics | ||||||
| Locking Type | Power to Release | |||||
| Holding Force, Max. | 1600 N (360 lb) | |||||
| Power Supply | 24V AC/DC or 110V AC or 230V AC | |||||
| Solenoid Power | 13 W typical 100% ED | |||||
| Operating Characteristics | ||||||
| Break Contact Force, Min. | 6 N (1.35 lbf) | |||||
| Actuation Speed, Max. | 160 mm (6.29 in.)/s | |||||
| Actuation Frequency, Max. | 2 cycles/s | |||||
| Operating Radius, Min | 60 mm (2.36 in.) | |||||
| Operating Life @ 100 mA load | 1,000,000 operations | |||||
| Environmental | ||||||
| Enclosure Type Rating | IP67 | |||||
| Operating Temperature [C (F)] | -25…+60° (13…+140°) | |||||
| Physical Characteristics | ||||||
| Housing Material | Painted zinc alloy | |||||
| Actuator Material | Stainless Steel | |||||
| Weight [g (lb)] | 1400 (3.08) | |||||
| Color | Red | |||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
||||||
Product Selection
| Solenoid Voltage | Contact | Actuator Type | Cat. No. | |||||
| Safety | Auxiliary | Action | M20 Conduit | Connector§ | ||||
| M20 | 1/2 inch NPT | 12-Pin M23 | 8-Pin Micro (M12)§ | |||||
| 24V AC/DC | 3 N.C. | 1 N.O. | BBM | GD2 standard | 440G-MT47037 | 440G-MT47039 | 440G-MT47041 | 440G-M3NBGDH-AC |
| Fully-flexible | 440G-MT47038 | 440G-MT47040 | 440G-MT47042 | 440G-M3NBBDH-AC | ||||
| — | 440G-MT47007 | 440G-MT47008 | 440G-MT47043 | — | ||||
| 2 N.C. | 2 N.O. | BBM | GD2 standard | 440G-MT47044 | 440G-MT47046 | 440G-MT47048 | — | |
| Fully-flexible | 440G-MT47045 | 440G-MT47047 | 440G-MT47049 | — | ||||
| — | 440G-MT47010 | 440G-MT47011 | 440G-MT47050 | — | ||||
| 24V DC with diagnostic function and metal override key | 3 N.C. | 1 N.O. | BBM | GD2 standard | 440G-MT47149 | 440G-MT47150 | 440G-MT47151 | — |
| Fully flexible | 440G-MT47152 | 440G-MT47153 | 440G-MT47154 | — | ||||
| No actuator | 440G-MT47155 | 440G-MT47156 | 440G-MT47157 | — | ||||
| 2 N.C. | 2 N.O. | BBM | GD2 standard | 440G-MT47158 | 440G-MT47159 | 440G-MT47160 | — | |
| Fully flexible | 440G-MT47161 | 440G-MT47162 | 440G-MT47163 | — | ||||
| No actuator | 440G-MT47164 | 440G-MT47165 | 440G-MT47166 | — | ||||
| 110V AC/DC | 3 N.C. | 1 N.O. | BBM | GD2 standard | 440G-MT47070 | 440G-MT47073 | — | — |
| Fully-flexible | 440G-MT47071 | 440G-MT47074 | — | — | ||||
| — | 440G-MT47013 | 440G-MT47009 | — | — | ||||
| 2 N.C. | 2 N.O. | BBM | GD2 standard | 440G-MT47077 | 440G-MT47079 | — | — | |
| Fully-flexible | 440G-MT47078 | 440G-MT47080 | — | — | ||||
| — | 440G-MT47012 | 440G-MT47014 | — | — | ||||
| 230V AC/DC | 3 N.C. | 1 N.O. | BBM | — | 440G-MT47016 | 440G-MT47017 | — | — |
| 2 N.C. | 2 N.O. | — | 440G-MT47015 | 440G-MT47024 | — | — | ||
§ For connector ratings see Safety Switches and Connectors.
§ With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Time Delay | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | ||||||||
| MSR127RP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | — | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Specialty Safety Relays | ||||||||
| MSR178 | 3 N.O. | 2 N.C. | 0.5 s…30 min | Removable | Automatic | 24V AC/DC, 115V AC or 230V AC | MSR178DP | 440R-M23227 |
| CU2 | 2 N.O. | 1 N.C. | 0.1 s…40 min | Fixed | — | 24V AC/DC | CU2 | 440R-S07281 |
| CU3 | 2 N.O. | 1 N.C. | — | Fixed | Automatic/Manual | 110V AC | CU3 | 440R-S35002 |
| Modular Safety Relays | ||||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | — | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | — | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 8-Pin Micro | 12-Pin M23 |
| Cordset | 889D-F8AB-¬ | 889M-F12AH-¬ |
| Patchcord | 889D-F8ABDM-T | 889M-F12AHMU- |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
Note: For additional information, see Safety Connection Systems.
Accessories
| Description | Dimensions | Cat. No. | |
|
|
GD2 standard actuator | Actuators¬ | 440G-A27011 |
|
|
GD2 flat actuator | 440K-A11112 | |
|
|
Fully flex actuator | 440G-A27143 | |
|
|
Sliding bolt actuator | 440G-A27163 | |
|
|
Extended flat actuator | 440K-A17116 | |
|
|
Replacement Cover, No LED, No Override Key | — | 440G-MT47120 |
| Replacement Cover, LED, Override Key | 440G-MT47123 | ||
|
|
Emergency Override Key (See Warning below.) |
— | 440G-A36026 |
|
|
Dust Cover | — | 440K-A17180 |
|
WARNING: Do not attach the Emergency Override Key to the 440G-MT switch. |
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|
Note: 2D, 3D and electrical drawings are available on www.ab.com.
Typical Wiring Diagrams
Diagnostic Version
| Actuator | LED Output Matrix | |
| Solenoid Off | Solenoid On | |
| In | Green | Amber |
| Out | Flashing Red | Red |
Diagnostic Electrical Output
| Actuator | Voltage |
| In | 0V DC |
| Out | +24V DC |
| Electrical output independent of solenoid status. Maximum output is 100 mA. | |