| Safety Ratings | ||||||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 | |||||
| Safety Classification | Cat. 1 Device per EN954-1 May be suitable for use in Cat 3 or Cat 4 systems depending on the architecture and application characteristics |
|||||
| Functional Safety Data (related to Safety Contacts) ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. load PFHD: < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
|||||
| Certifications | CE marked for all applicable directives, cULus, TÜV, and CCC | |||||
| Outputs | ||||||
| Safety Contacts T | 3 N.C. or 2 N.C. direct-opening action | |||||
| Auxiliary Contacts | 1 N.O. or 2 N.O. | |||||
| Thermal CurrentIlth | 10 A | |||||
| Rated Insulation Voltage | (Ui) 500V | |||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | |||||
| Utilization Category | ||||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V | |
| (le) | 1.2 A | 1.4 A | 3 A | 6 A | ||
| N600/DC-13 | (Ue) | 600V | 500V | 250V | 125V | 24V |
| (le) | 0.4 A | 0.55 A | 1.1 A | 2.2 A | 2 A | |
| Solenoid Characteristics | ||||||
| Locking Type | Power to Release | |||||
| Holding Force, Max. | 1600 N (360 lb) | |||||
| Power Supply | 24V AC/DC or 110V AC or 230V AC | |||||
| Solenoid Power | 13 W typical 100% ED | |||||
| Operating Characteristics | ||||||
| Break Contact Force, Min. | 6 N (1.35 lb) | |||||
| Actuation Speed, Max. | 160 mm (6.29 in) per second | |||||
| Actuation Frequency, Max. | 2 cycles per second | |||||
| Operating Radius, Min | 60 mm (2.36 in) | |||||
| Operating Life @ 100 mA load | 1,000,000 operations | |||||
| Environmental | ||||||
| Enclosure Type Rating | IP 67 | |||||
| Operating Temperature [C (F)] | -25…+60° (13…+140°) | |||||
| Physical Characteristics | ||||||
| Housing Material | Painted Zinc Alloy | |||||
| Actuator Material | Stainless-Steel | |||||
| Weight [g (lbs)] | 1400 (3.08) | |||||
| Color | Red | |||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
||||||