Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Guard Locking Switches > 440G-MT
440G-MT
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions | Typical Wiring Diagrams |
| Solenoid Voltage | Contact | Actuator Type | Cat. No. | |||||
| Safety | Auxiliary | Action | M20 Conduit | Connector§ | ||||
| M20 | 1/2 inch NPT | 12-Pin M23 | 8-Pin Micro (M12)§ | |||||
| 24V AC/DC | 3 N.C. | 1 N.O. | BBM | GD2 standard | 440G-MT47037 | 440G-MT47039 | 440G-MT47041 | 440G-M3NBGDH-AC |
| Fully-flexible | 440G-MT47038 | 440G-MT47040 | 440G-MT47042 | 440G-M3NBBDH-AC | ||||
| — | 440G-MT47007 | 440G-MT47008 | 440G-MT47043 | — | ||||
| 2 N.C. | 2 N.O. | BBM | GD2 standard | 440G-MT47044 | 440G-MT47046 | 440G-MT47048 | — | |
| Fully-flexible | 440G-MT47045 | 440G-MT47047 | 440G-MT47049 | — | ||||
| — | 440G-MT47010 | 440G-MT47011 | 440G-MT47050 | — | ||||
| 24V DC with diagnostic function and metal override key | 3 N.C. | 1 N.O. | BBM | GD2 standard | 440G-MT47149 | 440G-MT47150 | 440G-MT47151 | — |
| Fully flexible | 440G-MT47152 | 440G-MT47153 | 440G-MT47154 | — | ||||
| No actuator | 440G-MT47155 | 440G-MT47156 | 440G-MT47157 | — | ||||
| 2 N.C. | 2 N.O. | BBM | GD2 standard | 440G-MT47158 | 440G-MT47159 | 440G-MT47160 | — | |
| Fully flexible | 440G-MT47161 | 440G-MT47162 | 440G-MT47163 | — | ||||
| No actuator | 440G-MT47164 | 440G-MT47165 | 440G-MT47166 | — | ||||
| 110V AC/DC | 3 N.C. | 1 N.O. | BBM | GD2 standard | 440G-MT47070 | 440G-MT47073 | — | — |
| Fully-flexible | 440G-MT47071 | 440G-MT47074 | — | — | ||||
| — | 440G-MT47013 | 440G-MT47009 | — | — | ||||
| 2 N.C. | 2 N.O. | BBM | GD2 standard | 440G-MT47077 | 440G-MT47079 | — | — | |
| Fully-flexible | 440G-MT47078 | 440G-MT47080 | — | — | ||||
| — | 440G-MT47012 | 440G-MT47014 | — | — | ||||
| 230V AC/DC | 3 N.C. | 1 N.O. | BBM | — | 440G-MT47016 | 440G-MT47017 | — | — |
| 2 N.C. | 2 N.O. | — | 440G-MT47015 | 440G-MT47024 | — | — | ||
§ For connector ratings see Safety Switches and Connectors.
§ With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Time Delay | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | ||||||||
| MSR127RP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | — | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Specialty Safety Relays | ||||||||
| MSR178 | 3 N.O. | 2 N.C. | 0.5 s…30 min | Removable | Automatic | 24V AC/DC, 115V AC or 230V AC | MSR178DP | 440R-M23227 |
| CU2 | 2 N.O. | 1 N.C. | 0.1 s…40 min | Fixed | — | 24V AC/DC | CU2 | 440R-S07281 |
| CU3 | 2 N.O. | 1 N.C. | — | Fixed | Automatic/Manual | 110V AC | CU3 | 440R-S35002 |
| Modular Safety Relays | ||||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | — | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | — | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 8-Pin Micro | 12-Pin M23 |
| Cordset | 889D-F8AB-¬ | 889M-F12AH-¬ |
| Patchcord | 889D-F8ABDM-T | 889M-F12AHMU- |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
Note: For additional information, see Safety Connection Systems.