Guard Locking Switches

Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Guard Locking Switches > 440G-MT

440G-MT

Introduction Specifications Product Selection Accessories Approximate Dimensions Typical Wiring Diagrams
Product Selection

Solenoid Voltage Contact Actuator Type Cat. No.
Safety Auxiliary Action M20 Conduit Connector§ 
M20 1/2 inch NPT 12-Pin M23 8-Pin Micro (M12)§ 
24V AC/DC 3 N.C. 1 N.O. BBM GD2 standard 440G-MT47037 440G-MT47039 440G-MT47041 440G-M3NBGDH-AC
Fully-flexible 440G-MT47038 440G-MT47040 440G-MT47042 440G-M3NBBDH-AC
440G-MT47007 440G-MT47008 440G-MT47043
2 N.C. 2 N.O. BBM GD2 standard 440G-MT47044 440G-MT47046 440G-MT47048
Fully-flexible 440G-MT47045 440G-MT47047 440G-MT47049
440G-MT47010 440G-MT47011 440G-MT47050
24V DC with diagnostic function and metal override key 3 N.C. 1 N.O. BBM GD2 standard 440G-MT47149 440G-MT47150 440G-MT47151
Fully flexible 440G-MT47152 440G-MT47153 440G-MT47154
No actuator 440G-MT47155 440G-MT47156 440G-MT47157
2 N.C. 2 N.O. BBM GD2 standard 440G-MT47158 440G-MT47159 440G-MT47160
Fully flexible 440G-MT47161 440G-MT47162 440G-MT47163
No actuator 440G-MT47164 440G-MT47165 440G-MT47166
110V AC/DC 3 N.C. 1 N.O. BBM GD2 standard 440G-MT47070 440G-MT47073
Fully-flexible 440G-MT47071 440G-MT47074
440G-MT47013 440G-MT47009
2 N.C. 2 N.O. BBM GD2 standard 440G-MT47077 440G-MT47079
Fully-flexible 440G-MT47078 440G-MT47080
440G-MT47012 440G-MT47014
230V AC/DC 3 N.C. 1 N.O. BBM 440G-MT47016 440G-MT47017
2 N.C. 2 N.O. 440G-MT47015 440G-MT47024
 

§ For connector ratings see Safety Switches and Connectors.
§ With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.


Recommended Logic Interfaces

Description Safety Outputs Auxiliary Outputs Time Delay Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays
MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC MSR127RP/TP 440R-N23135
MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC MSR127RP/TP 440R-N23132
MSR126T 2 N.O. None Fixed Auto./Manual 24V AC/DC MSR126R/T 440R-N23117
MSR30RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC MSR30RT/RTP 440R-N23198
Specialty Safety Relays
MSR178 3 N.O. 2 N.C. 0.5 s…30 min Removable Automatic 24V AC/DC, 115V AC or 230V AC MSR178DP 440R-M23227
CU2 2 N.O. 1 N.C. 0.1 s…40 min Fixed 24V AC/DC CU2 440R-S07281
CU3 2 N.O. 1 N.C. Fixed Automatic/Manual 110V AC CU3 440R-S35002
Modular Safety Relays
MSR210P Base
2 N.C. only
2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit MSR210P 440R-H23176
MSR220P Input Module Removable 24V DC MSR220P 440R-H23178
MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC MSR310P 440R-W23219
MSR320P Input Module 2 PNP Solid State Removable 24V DC from the base unit MSR320P 440R-W23218
  

Note:  For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.


Connection Systems

Description 8-Pin Micro 12-Pin M23
Cordset 889D-F8AB-¬  889M-F12AH-¬ 
Patchcord 889D-F8ABDM-T  889M-F12AHMU-‡ 
  

¬  Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T  Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
‡  Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
Note:  For additional information, see Safety Connection Systems.