TLS-GD2
|
Description
The TLS-GD2 is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and ensures that it remains isolated while the guard is open. It has three safety (N.C.) contacts and two auxiliary (N.O.) contacts. The TLS-GD2 head has two entry slots and it can be rotated to provide four actuator entry points. A blanking plug is provided to seat the unused slot.
The guard may only be opened when a signal is applied to the TLS-GD2 internal solenoid which releases the lock mechanism. This signal can be via CU1 electronic timer relays or CU2 stopped motion detectors. Therefore the TLS-GD2 is ideal for machines which do not stop immediately or where premature interruption of the machine could cause damage to tooling and components or cause an additional hazard.
The TLS-GD2 is available in three types. The TLS-1 GD2 and TLS-3 GD2 incorporate a power-to-release function. Two manual release points with security screws allow the locked TLS-GD2 to be released in emergencies. An optional lid-mounted key-release style can also be supplied. The TLS-2 GD2 has a power-to-lock function. Each type of switch has five sets of contacts of various forms and are suitable for use with PLCs.
The TLS-1 GD2 and TLS-3 GD2 are both available with escape release options. They are intended for machine guarding with full body access. The switch is installed so that the escape release push button on the rear side is accessible from inside the hazardous area. This allows the intentional unlocking of the TLS-GD2 from inside a hazardous area, providing a means of escape for a person who may become trapped.
A stainless-steel actuator guide is fitted to protect the unit from actuator damage due to poor guard alignment or guard wear.
TLS-GD2 has an ingress protection rating of IP69K making it suitable for harsh washdown applications as found in the food and beverage, pharmaceutical, solar and semiconductor industries.
|
IMPORTANT: With the TLS-2 GD2 power to lock style, provisions may be required to ensure that a dangerous situation can not result from open circuit faults or power cuts. |
Features
- Power to release or power to lock
- High locking force £2000 N (450 lb)
- Five contacts: 2 N.C. & 1 N.O. for door position monitoring 1 N.C. & 1 N.O. or 2 N.C. for lock monitoring
- Rotatable head: 4 possible key entry slots
- Conforms to EN 1088 & EN 60947-5-1
- Escape Release version available
- IP69K, suitable for high pressure, high temperature washdown
Specifications
| Safety Ratings | |||||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/EN60947-5-1, ANSI B11.19, AS4024.1 | ||||
| Safety Classification | Cat. 1 device per EN 954-1 dual channel interlocks suitable for Cat. 3 or 4 systems | ||||
| Functional Safety Data (related to Safety Contacts) ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. load PFHD: < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
||||
| Certifications | CE Marked for all applicable directives, cULus, TÜV, and CCC | ||||
| Outputs | |||||
| Safety Contacts T | (TLS-1 & -2) 3 N.C. direct opening action (TLS-3) 4 N.C. direct opening action |
||||
| Auxiliary Contacts | (TLS-1 & -2) 2 N.O. (1 solenoid monitoring) (TLS-3 1 N.O.) |
||||
| Thermal CurrentIlth | 10 A | ||||
| Rated Insulation Voltage | (Ui) 500V | ||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | ||||
| Utilization Category | |||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V |
| (le) | 1.2 A | 1.4 A | 3.0 A | 6.0 A | |
| DC-13 | (Ue) | 24V | |||
| (le) | 2 A | ||||
| Solenoid Characteristics | |||||
| Locking Type | TLS-1 & -3 Power-to-Release TLS-2 Power-to-Lock | ||||
| Holding Force, Max. | 2000 N (450 lbf) | ||||
| Releasable Load, Max. | 100 N (22.5 lbf) | ||||
| Power Supply | 24V AC/DC or 110V AC or 230V AC (solenoid) | ||||
| Solenoid Power | Typically 7 W 100% ED | ||||
| Escape Release Button | Force max.: 50 N (11.25 lbs) | ||||
| Operating Characteristics | |||||
| Break Contact Force, Min. | 20 N (4.5 lbf) | ||||
| Actuation Speed, Max. | 160 mm (6.29 in.)/s | ||||
| Actuation Frequency, Max. | 1 cycle/s | ||||
| Operating Radius, Min | 160 mm (6.3 in.) [80 mm (3.15 in.) with flexible actuator] | ||||
| Operating Life @ 100 mA load | 1,000,000 operations | ||||
| Environmental | |||||
| Enclosure Type Rating | IP66, IP67 and IP69K | ||||
| Operating Temperature [C (F)] | -20…+60° (-4…+140°) | ||||
| Physical Characteristics | |||||
| Housing Material | UL Approved glass-filled PBT | ||||
| Actuator Material | Stainless Steel | ||||
| Weight [g (lb)] | 400 (0.88) | ||||
| Color | Red | ||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10mins., 24hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
|||||
Product Selection
| Type | Contacts | Solenoid | Actuator Type | Cat. No. | |||||
| Safety | Auxiliary | Contacts | Voltage | Conduit | Connector§ | ||||
| M20 | 1/2 inch NPT Adaptor | 12-Pin M23 | 8-Pin Micro (M12)§ | ||||||
| TLS-1 GD2 Power to Release | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T27121 | — | 440G-T27233 | 440G-T2NBBPH-1R |
| GD2 Standard | 440G-T27251 | 440G-T27169 | 440G-T27234 | — | |||||
| Fully Flex | 440G-T27252 | 440G-T27171 | 440G-T27235 | — | |||||
| 110V AC/DC | — | 440G-T27124 | — | — | — | ||||
| GD2 Standard | 440G-T27253 | 440G-T27172 | — | — | |||||
| Fully Flex | 440G-T27254 | 440G-T27174 | — | — | |||||
| 230V AC/DC | — | 440G-T27123 | — | — | — | ||||
| TLS-2 GD2 Power to Lock | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T27127 | — | 440G-T27239 | 440G-T2NBBPH-1L |
| GD2 Standard | 440G-T27255 | 440G-T27175 | 440G-T27240 | — | |||||
| Fully Flex | 440G-T27256 | 440G-T27177 | 440G-T27241 | — | |||||
| 110V AC/DC | — | 440G-T27132 | — | — | — | ||||
| GD2 Standard | 440G-T27257 | 440G-T27178 | — | — | |||||
| Fully Flex | 440G-T27258 | 440G-T27180 | — | — | |||||
| 230V AC/DC | — | 440G-T27129 | — | — | — | ||||
| TLS-3 GD2 Power to Release | 2 N.C. | 1 N.O. | 2 N.C. | 24V AC/DC | — | 440G-T27134 | — | 440G-T27245 | 440G-T2NBBPH-2R |
| GD2 Standard | 440G-T27259 | 440G-T27181 | 440G-T27246 | — | |||||
| Fully Flex | 440G-T27260 | 440G-T27183 | 440G-T27247 | — | |||||
| 110V AC/DC | — | 440G-T27138 | — | — | — | ||||
| GD2 Standard | 440G-T27261 | 440G-T27184 | — | — | |||||
| Fully Flex | 440G-T27262 | 440G-T27186 | — | — | |||||
| 230V AC/DC | — | 440G-T27136 | — | — | — | ||||
| TLS-1 GD2 Power to Release with Escape Release | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T21BNPM-1B | 440G-T21BNPT-1B | 440G-T21BNPL-1B | 440G-T2NBNPH-1B |
| GD2 Standard | 440G-T21BGPM-1B | 440G-T21BGPT-1B | 440G-T21BGPL-1B | — | |||||
| 110V AC/DC | — | 440G-T21BNPM-4B | 440G-T21BNPT-4B | — | — | ||||
| GD2 Standard | 440G-T21BGPM-4B | 440G-T21BGPT-4B | — | — | |||||
| TLS-3 GD2 Power to Release with Escape Release | 2 N.C. | 1 N.O. | 2 N.C. | 24V AC/DC | — | 440G-T21BNPM-2B | 440G-T21BNPT-2B | 440G-T21BNPL-2B | 440G-T2NBNPH-2B |
| GD2 Standard | 440G-T21BGPM-2B | 440G-T21BGPT-2B | 440G-T21BGPL-2B | — | |||||
| 110V AC/DC | — | 440G-T21BNPM-5B | 440G-T21BNPT-5B | — | — | ||||
| GD2 Standard | 440G-T21BGPM-5B | 440G-T21BGPT-5B | — | — | |||||
§ For connector ratings, see page Safety Switches and Connectors.
§ With an 8-pin micro connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Time Delay | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | ||||||||
| MSR127RP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | — | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Specialty Safety Relays | ||||||||
| MSR178 | 3 N.O. | 2 N.C. | 0.5 s…30 min | Removable | Automatic | 24V AC/DC, 115V AC or 230V AC | MSR178DP | 440R-M23227 |
| CU2 | 2 N.O. | 1 N.C. | 0.1 s…40 min | Fixed | — | 24V AC/DC | CU2 | 440R-S07281 |
| CU3 | 2 N.O. | 1 N.C. | — | Fixed | Automatic/Manual | 110V AC | CU3 | 440R-S35002 |
| Modular Safety Relays | ||||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | — | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | — | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 8-Pin Micro (M12) | 12-Wire, 12-Pin M23 |
9-Wire, 12-Pin M23§ |
| Cordset | 889D-F8AB-¬ | 889M-F12AH-¬ | 889M-F12X9AE-¬ |
| Patchcord | 889D-F8ABDM-T | 889M-F12AHMU- | — |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
§ The 9-wire cordset can be used only with the TLS3 versions.
Note: For additional information, see Safety Connection Systems.
Accessories
| Description | Dimensions | Cat. No. | ||
|
GD2 standard actuator | Actuators¬ | 440G-A27011 | |
|
GD2 flat actuator | 440K-A11112 | ||
|
Extended flat actuator | 440K-A17116 | ||
|
Fully flex actuator | 440G-A27143 | ||
|
Sliding bolt actuator not to be used with the TLS1 Escape Release | Door Handles | 440G-A27163 | |
|
Cover for TLS-1 with external override key for series D and earlier | — | 440G-A27140 | |
| Cover for TLS-3 with external override key for series D and earlier | 440G-A27142 | |||
| Cover for TLS-1 with override key attached for series D and earlier | 440G-A27207 | |||
| Cover for TLS-3 with override key attached for series D and earlier | 440G-A27208 | |||
| Cover for TLS-1 with external override key for series E and later | 440G-A27371 | |||
| Cover for TLS-3 with external override key for series E and later | 440G-A27372 | |||
| Cover for TLS-1 with override key attached for series E and later | 440G-A27373 | |||
| Cover for TLS-3 with override key attached for series E and later | 440G-A27374 | |||
|
Emergency Override Key (See Warning below.) |
— | 440G-A36026 | |
|
Flexible Release—1 m (3.28 ft) Cable | Flex Release | 440G-A27356 | |
| Flexible Release—3 m (9.84 ft) Cable | 440G-A27357 | |||
|
|
Dust Cover | — | 440K-A17183 | |
|
Sliding Bolt | Door Handles | 440K-AMDS | |
|
|
|
Mounting Plate | Door Handles | 440K-AMDSSMPB |
|
WARNING: Do not attach the Emergency Override Key to the TLS-GD2 switch. |
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|
TLS-GD2 Escape Release
|
Note: 2D, 3D and electrical drawings are available on www.ab.com.
Typical Wiring Diagrams