TLS-GD2
|
Description
The TLS-GD2 is a positive-mode, tongue-operated guard-locking interlock switch that locks a machine guard closed until power is isolated while the guard is open. The TLS-GD2 head has two entry slots and can be rotated to provide four actuator entry points. A blanking plug is provided to seal the unused slot.
Power can only be restored through the guard after a signal is applied to the TLS-GD2s internal solenoid to release the locking mechanism. Therefore, the TLS-GD2 is ideal for machines which do not stop immediately or where premature interruption of the machine could cause damage to tooling and components or cause an additional hazard.
The TLS-GD2 is available in three types. The TLS-1 GD2 and TLS-3 GD2 incorporate a power-to-release function. Three manual release points with security screws allow the locked TLS-GD2 to be released in emergencies. An optional lid-mounted key-release style can also be supplied. The TLS-2 GD2 has a power-to-lock function. Each type of switch has five sets of contacts of various forms and are suitable for use with PLCs.
The TLS-1 GD2 and TLS-3 GD2 are both available with Escape Release options. They are intended for machine guarding with full body access. The switch is installed so that the escape release push button on the rear side is accessible from inside the hazardous area. This allows the intentional unlocking of the TLS-GD2 from inside a hazardous area, providing a means of escape for a person who may become trapped.
A stainless-steel actuator guide is fitted to protect the unit from actuator damage due to poor guard alignment or guard wear.
|
IMPORTANT: With the TLS-2 GD2 power to lock style, provisions may be required to ensure that a dangerous situation can not result from open circuit faults or power cuts. |
Features
- Power to release or power to lock
- High locking force £2000 N (450 lbs)
- Five contacts: 2 N.C. & 1 N.O. for door position monitoring 1 N.C. & 1 N.O. or 2 N.C. for lock monitoring
- Rotatable head: 4 possible key entry slots
- Conforms to EN 1088 & EN 60947-5-1
- Escape Release version available
Specifications
| Safety Ratings | |||||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 | ||||
| Safety Classification | Cat. 1 Device per EN954-1 Dual-channel interlocks suitable for Cat. 3 or 4 systems | ||||
| Functional Safety Data (related to Safety Contacts) ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. load PFHD: < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
||||
| Certifications | CE marked for all applicable directives, cULus, TÜV, and CCC | ||||
| Outputs | |||||
| Safety Contacts T | (TLS-1 & -2) 3 N.C. direct-opening action (TLS-3) 4 N.C. direct-opening action |
||||
| Auxiliary Contacts | (TLS-1 & -2) 2 N.O. (1 solenoid monitoring) (TLS-3 1 N.O.) |
||||
| Thermal CurrentIlth | 10 A | ||||
| Rated Insulation Voltage | (Ui) 500V | ||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | ||||
| Utilization Category | |||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V |
| (le) | 1.2 A | 1.4 A | 3.0 A | 6.0 A | |
| N600/DC-13 | (Ue) | 600V | 500V | 250V | 125V |
| (le) | 0.4 A | 0.55 A | 1.1 A | 2.2 A | |
| Solenoid Characteristics | |||||
| Locking Type | TLS-1 & -3 Power-to-Release TLS-2 Power-to-Lock | ||||
| Holding Force, Max. | 2000 N (450 lbs) | ||||
| Releasable Load, Max. | 100 N (22.5 lbs) | ||||
| Power Supply | 24V AC/DC or 110V AC or 230V AC (solenoid) | ||||
| Solenoid Power | Typically 7 W 100% ED | ||||
| Escape Release Button | Force max.: 50 N (11.25 lbs) | ||||
| Operating Characteristics | |||||
| Break Contact Force, Min. | 12 N (2.7 lbs) | ||||
| Actuation Speed, Max. | 160 mm per sec (6.3 ins per sec) | ||||
| Actuation Frequency, Max. | 1 Cycle per sec | ||||
| Operating Radius, Min | 160 mm (6.3 in) (80 mm (3.15 in) with flexible actuator) | ||||
| Operating Life @ 100 mA load | 1,000,000 operations | ||||
| Environmental | |||||
| Enclosure Type Rating | IP 67 | ||||
| Operating Temperature [C (F)] | -20…+ 60° (-4…+140°) | ||||
| Physical Characteristics | |||||
| Housing Material | UL approved glass-filled PBT | ||||
| Actuator Material | Stainless Steel | ||||
| Weight [g (lbs)] | 400 (0.88) | ||||
| Color | Red | ||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10mins., 24hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
|||||
Product Selection
| Type | Contacts | Solenoid | Actuator Type | Cat. No. | |||||
| Safety | Auxiliary | Contacts | Voltage | Conduit | Connector§ | ||||
| M20 | 1/2 inch NPT Adaptor | 12-Pin M23 | 8-Pin Micro (M12)§ | ||||||
| TLS-1 GD2 Power to Release | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T27121 | — | 440G-T27233 | 440G-T2NBBPH-1R |
| GD2 Standard | 440G-T27251 | 440G-T27169 | 440G-T27234 | — | |||||
| Fully Flex | 440G-T27252 | 440G-T27171 | 440G-T27235 | — | |||||
| 110V AC/DC | — | 440G-T27124 | — | — | — | ||||
| GD2 Standard | 440G-T27253 | 440G-T27172 | — | — | |||||
| Fully Flex | 440G-T27254 | 440G-T27174 | — | — | |||||
| 230V AC/DC | — | 440G-T27123 | — | — | — | ||||
| TLS-2 GD2 Power to Lock | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T27127 | — | 440G-T27239 | 440G-T2NBBPH-1L |
| GD2 Standard | 440G-T27255 | 440G-T27175 | 440G-T27240 | — | |||||
| Fully Flex | 440G-T27256 | 440G-T27177 | 440G-T27241 | — | |||||
| 110V AC/DC | — | 440G-T27132 | — | — | — | ||||
| GD2 Standard | 440G-T27257 | 440G-T27178 | — | — | |||||
| Fully Flex | 440G-T27258 | 440G-T27180 | — | — | |||||
| 230V AC/DC | — | 440G-T27129 | — | — | — | ||||
| TLS-3 GD2 Power to Release | 2 N.C. | 1 N.O. | 2 N.C. | 24V AC/DC | — | 440G-T27134 | — | 440G-T27245 | 440G-T2NBBPH-2R |
| GD2 Standard | 440G-T27259 | 440G-T27181 | 440G-T27246 | — | |||||
| Fully Flex | 440G-T27260 | 440G-T27183 | 440G-T27247 | — | |||||
| 110V AC/DC | — | 440G-T27138 | — | — | — | ||||
| GD2 Standard | 440G-T27261 | 440G-T27184 | — | — | |||||
| Fully Flex | 440G-T27262 | 440G-T27186 | — | — | |||||
| 230V AC/DC | — | 440G-T27136 | — | — | — | ||||
| TLS-1 GD2 Power to Release with Escape Release | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T21BNPM-1B | 440G-T21BNPT-1B | 440G-T21BNPL-1B | 440G-T2NBNPH-1B |
| GD2 Standard | 440G-T21BGPM-1B | 440G-T21BGPT-1B | 440G-T21BGPL-1B | — | |||||
| 110V AC/DC | — | 440G-T21BNPM-4B | 440G-T21BNPT-4B | — | — | ||||
| GD2 Standard | 440G-T21BGPM-4B | 440G-T21BGPT-4B | — | — | |||||
| TLS-3 GD2 Power to Release with Escape Release | 2 N.C. | 1 N.O. | 2 N.C. | 24V AC/DC | — | 440G-T21BNPM-2B | 440G-T21BNPT-2B | 440G-T21BNPL-2B | 440G-T2NBNPH-2B |
| GD2 Standard | 440G-T21BGPM-2B | 440G-T21BGPT-2B | 440G-T21BGPL-2B | — | |||||
| 110V AC/DC | — | 440G-T21BNPM-5B | 440G-T21BNPT-5B | — | — | ||||
| GD2 Standard | 440G-T21BGPM-5B | 440G-T21BGPT-5B | — | — | |||||
§ For connector ratings, see page Safety Switches and Connectors.
§ With an 8-pin micro connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Time Delay | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | ||||||||
| MSR127RP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | — | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Specialty Safety Relays | ||||||||
| MSR178 | 3 N.O. | 2 N.C. | 0.5 s…30 min | Removable | Automatic | 24V AC/DC, 115V AC or 230V AC | MSR178DP | 440R-M23227 |
| CU2 | 2 N.O. | 1 N.C. | 0.1 s…40 min | Fixed | — | 24V AC/DC | CU2 | 440R-S07281 |
| CU3 | 2 N.O. | 1 N.C. | — | Fixed | Automatic/Manual | 110V AC | CU3 | 440R-S35002 |
| Modular Safety Relays | ||||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | — | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | — | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 8-Pin Micro (M12) | 12-Wire, 12-Pin M23 |
9-Wire, 12-Pin M23§ |
| Cordset | 889D-F8AB-¬ | 889M-F12AH-¬ | 889M-F12X9AE-¬ |
| Patchcord | 889D-F8ABDM-T | 889M-F12AHMU- | — |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
§ The 9-wire cordset can be used only with the TLS3 versions.
Note: For additional information, see Safety Connection Systems.
Accessories
| Description | Dimensions | Cat. No. | ||
|
GD2 Standard Actuator | Actuators | 440G-A27011 | |
|
GD2 Flat Actuator | 440K-A11112 | ||
|
Extended Flat Actuator | 440K-A17116 | ||
|
Fully Flexible Actuator | 440G-A27143 | ||
|
Sliding Bolt Actuator not to be used with the TLS1 Escape Release | Door Handles | 440G-A27163 | |
|
Replacement Cover for TLS-1 with External Override Key | Replacement Covers | 440G-A27140 | |
| Replacement Cover for TLS-3 with External Override Key | 440G-A27142 | |||
| Replacement Cover for TLS-1 with Override Key Attached | 440G-A27207 | |||
| Replacement Cover for TLS-3 with Override Key Attached | 440G-A27208 | |||
|
Emergency Override Key (See Warning below.) |
Emergency Override | 440G-A36026 | |
|
Flexible Release—1 m (3.28 ft) Cable | Flex Release | 440G-A27356 | |
| Flexible Release—3 m (9.84 ft) Cable | 440G-A27357 | |||
|
|
Dust Cover | Dust Covers | 440K-A17183 | |
|
Sliding Bolt | Door Handles | 440K-AMDS | |
|
|
|
Mounting Plate | Door Handles | 440K-AMDSSMPB |
|
WARNING: Do not attach the Emergency Override Key to the TLS-GD2 switch. |
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
|
TLS-GD2 Escape Release
|
Note: 2D, 3D and electrical drawings are available on www.ab.com.
Typical Wiring Diagrams