Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Guard Locking Switches > TLS-GD2
TLS-GD2
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions—mm (inches) | Typical Wiring Diagrams |
| Safety Ratings | |||||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 | ||||
| Safety Classification | Cat. 1 Device per EN954-1 Dual-channel interlocks suitable for Cat. 3 or 4 systems | ||||
| Functional Safety Data (related to Safety Contacts) ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. load PFHD: < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
||||
| Certifications | CE marked for all applicable directives, cULus, TÜV, and CCC | ||||
| Outputs | |||||
| Safety Contacts T | (TLS-1 & -2) 3 N.C. direct-opening action (TLS-3) 4 N.C. direct-opening action |
||||
| Auxiliary Contacts | (TLS-1 & -2) 2 N.O. (1 solenoid monitoring) (TLS-3 1 N.O.) |
||||
| Thermal CurrentIlth | 10 A | ||||
| Rated Insulation Voltage | (Ui) 500V | ||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | ||||
| Utilization Category | |||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V |
| (le) | 1.2 A | 1.4 A | 3.0 A | 6.0 A | |
| N600/DC-13 | (Ue) | 600V | 500V | 250V | 125V |
| (le) | 0.4 A | 0.55 A | 1.1 A | 2.2 A | |
| Solenoid Characteristics | |||||
| Locking Type | TLS-1 & -3 Power-to-Release TLS-2 Power-to-Lock | ||||
| Holding Force, Max. | 2000 N (450 lbs) | ||||
| Releasable Load, Max. | 100 N (22.5 lbs) | ||||
| Power Supply | 24V AC/DC or 110V AC or 230V AC (solenoid) | ||||
| Solenoid Power | Typically 7 W 100% ED | ||||
| Escape Release Button | Force max.: 50 N (11.25 lbs) | ||||
| Operating Characteristics | |||||
| Break Contact Force, Min. | 12 N (2.7 lbs) | ||||
| Actuation Speed, Max. | 160 mm per sec (6.3 ins per sec) | ||||
| Actuation Frequency, Max. | 1 Cycle per sec | ||||
| Operating Radius, Min | 160 mm (6.3 in) (80 mm (3.15 in) with flexible actuator) | ||||
| Operating Life @ 100 mA load | 1,000,000 operations | ||||
| Environmental | |||||
| Enclosure Type Rating | IP 67 | ||||
| Operating Temperature [C (F)] | -20…+ 60° (-4…+140°) | ||||
| Physical Characteristics | |||||
| Housing Material | UL approved glass-filled PBT | ||||
| Actuator Material | Stainless Steel | ||||
| Weight [g (lbs)] | 400 (0.88) | ||||
| Color | Red | ||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10mins., 24hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
|||||