Guard Locking Switches

Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Guard Locking Switches > TLS-GD2

TLS-GD2

Introduction Specifications Product Selection Accessories Approximate Dimensions—mm (inches) Typical Wiring Diagrams
Product Selection

Type Contacts Solenoid Actuator Type Cat. No.
Safety Auxiliary Contacts Voltage Conduit Connector§ 
M20 1/2 inch NPT Adaptor 12-Pin M23 8-Pin Micro (M12)§ 
TLS-1 GD2 Power to Release 2 N.C. 1 N.O. 1 N.C. & 1 N.O. 24V AC/DC 440G-T27121 440G-T27233 440G-T2NBBPH-1R
GD2 Standard 440G-T27251 440G-T27169 440G-T27234
Fully Flex 440G-T27252 440G-T27171 440G-T27235
110V AC/DC 440G-T27124
GD2 Standard 440G-T27253 440G-T27172
Fully Flex 440G-T27254 440G-T27174
230V AC/DC 440G-T27123
TLS-2 GD2 Power to Lock 2 N.C. 1 N.O. 1 N.C. & 1 N.O. 24V AC/DC 440G-T27127 440G-T27239 440G-T2NBBPH-1L
GD2 Standard 440G-T27255 440G-T27175 440G-T27240
Fully Flex 440G-T27256 440G-T27177 440G-T27241
110V AC/DC 440G-T27132
GD2 Standard 440G-T27257 440G-T27178
Fully Flex 440G-T27258 440G-T27180
230V AC/DC 440G-T27129
TLS-3 GD2 Power to Release 2 N.C. 1 N.O. 2 N.C. 24V AC/DC 440G-T27134 440G-T27245 440G-T2NBBPH-2R
GD2 Standard 440G-T27259 440G-T27181 440G-T27246
Fully Flex 440G-T27260 440G-T27183 440G-T27247
110V AC/DC 440G-T27138
GD2 Standard 440G-T27261 440G-T27184
Fully Flex 440G-T27262 440G-T27186
230V AC/DC 440G-T27136
TLS-1 GD2 Power to Release with Escape Release 2 N.C. 1 N.O. 1 N.C. & 1 N.O. 24V AC/DC 440G-T21BNPM-1B 440G-T21BNPT-1B 440G-T21BNPL-1B 440G-T2NBNPH-1B
GD2 Standard 440G-T21BGPM-1B 440G-T21BGPT-1B 440G-T21BGPL-1B
110V AC/DC 440G-T21BNPM-4B 440G-T21BNPT-4B
GD2 Standard 440G-T21BGPM-4B 440G-T21BGPT-4B
TLS-3 GD2 Power to Release with Escape Release 2 N.C. 1 N.O. 2 N.C. 24V AC/DC 440G-T21BNPM-2B 440G-T21BNPT-2B 440G-T21BNPL-2B 440G-T2NBNPH-2B
GD2 Standard 440G-T21BGPM-2B 440G-T21BGPT-2B 440G-T21BGPL-2B
110V AC/DC 440G-T21BNPM-5B 440G-T21BNPT-5B
GD2 Standard 440G-T21BGPM-5B 440G-T21BGPT-5B
 

§ For connector ratings, see page Safety Switches and Connectors.
§ With an 8-pin micro connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.


Recommended Logic Interfaces

Description Safety Outputs Auxiliary Outputs Time Delay Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays
MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC MSR127RP/TP 440R-N23135
MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC MSR127RP/TP 440R-N23132
MSR126T 2 N.O. None Fixed Auto./Manual 24V AC/DC MSR126R/T 440R-N23117
MSR30RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC MSR30RT/RTP 440R-N23198
Specialty Safety Relays
MSR178 3 N.O. 2 N.C. 0.5 s…30 min Removable Automatic 24V AC/DC, 115V AC or 230V AC MSR178DP 440R-M23227
CU2 2 N.O. 1 N.C. 0.1 s…40 min Fixed 24V AC/DC CU2 440R-S07281
CU3 2 N.O. 1 N.C. Fixed Automatic/Manual 110V AC CU3 440R-S35002
Modular Safety Relays
MSR210P Base
2 N.C. only
2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit MSR210P 440R-H23176
MSR220P Input Module Removable 24V DC MSR220P 440R-H23178
MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC MSR310P 440R-W23219
MSR320P Input Module 2 PNP Solid State Removable 24V DC from the base unit MSR320P 440R-W23218
  

Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.


Connection Systems

Description 8-Pin Micro (M12) 12-Wire,
12-Pin M23
9-Wire,
12-Pin M23§ 
Cordset 889D-F8AB-¬  889M-F12AH-¬  889M-F12X9AE-¬ 
Patchcord 889D-F8ABDM-T  889M-F12AHMU-‡ 
  

¬  Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T  Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
‡  Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
§  The 9-wire cordset can be used only with the TLS3 versions.
Note: For additional information, see Safety Connection Systems.