| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions—mm (inches) | Typical Wiring Diagrams |
| Type | Contacts | Solenoid | Actuator Type | Cat. No. | |||||
| Safety | Auxiliary | Contacts | Voltage | Conduit | Connector§ | ||||
| M20 | 1/2 inch NPT Adaptor | 12-Pin M23 | 8-Pin Micro (M12)§ | ||||||
| TLS-1 GD2 Power to Release | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T27121 | — | 440G-T27233 | 440G-T2NBBPH-1R |
| GD2 Standard | 440G-T27251 | 440G-T27169 | 440G-T27234 | — | |||||
| Fully Flex | 440G-T27252 | 440G-T27171 | 440G-T27235 | — | |||||
| 110V AC/DC | — | 440G-T27124 | — | — | — | ||||
| GD2 Standard | 440G-T27253 | 440G-T27172 | — | — | |||||
| Fully Flex | 440G-T27254 | 440G-T27174 | — | — | |||||
| 230V AC/DC | — | 440G-T27123 | — | — | — | ||||
| TLS-2 GD2 Power to Lock | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T27127 | — | 440G-T27239 | 440G-T2NBBPH-1L |
| GD2 Standard | 440G-T27255 | 440G-T27175 | 440G-T27240 | — | |||||
| Fully Flex | 440G-T27256 | 440G-T27177 | 440G-T27241 | — | |||||
| 110V AC/DC | — | 440G-T27132 | — | — | — | ||||
| GD2 Standard | 440G-T27257 | 440G-T27178 | — | — | |||||
| Fully Flex | 440G-T27258 | 440G-T27180 | — | — | |||||
| 230V AC/DC | — | 440G-T27129 | — | — | — | ||||
| TLS-3 GD2 Power to Release | 2 N.C. | 1 N.O. | 2 N.C. | 24V AC/DC | — | 440G-T27134 | — | 440G-T27245 | 440G-T2NBBPH-2R |
| GD2 Standard | 440G-T27259 | 440G-T27181 | 440G-T27246 | — | |||||
| Fully Flex | 440G-T27260 | 440G-T27183 | 440G-T27247 | — | |||||
| 110V AC/DC | — | 440G-T27138 | — | — | — | ||||
| GD2 Standard | 440G-T27261 | 440G-T27184 | — | — | |||||
| Fully Flex | 440G-T27262 | 440G-T27186 | — | — | |||||
| 230V AC/DC | — | 440G-T27136 | — | — | — | ||||
| TLS-1 GD2 Power to Release with Escape Release | 2 N.C. | 1 N.O. | 1 N.C. & 1 N.O. | 24V AC/DC | — | 440G-T21BNPM-1B | 440G-T21BNPT-1B | 440G-T21BNPL-1B | 440G-T2NBNPH-1B |
| GD2 Standard | 440G-T21BGPM-1B | 440G-T21BGPT-1B | 440G-T21BGPL-1B | — | |||||
| 110V AC/DC | — | 440G-T21BNPM-4B | 440G-T21BNPT-4B | — | — | ||||
| GD2 Standard | 440G-T21BGPM-4B | 440G-T21BGPT-4B | — | — | |||||
| TLS-3 GD2 Power to Release with Escape Release | 2 N.C. | 1 N.O. | 2 N.C. | 24V AC/DC | — | 440G-T21BNPM-2B | 440G-T21BNPT-2B | 440G-T21BNPL-2B | 440G-T2NBNPH-2B |
| GD2 Standard | 440G-T21BGPM-2B | 440G-T21BGPT-2B | 440G-T21BGPL-2B | — | |||||
| 110V AC/DC | — | 440G-T21BNPM-5B | 440G-T21BNPT-5B | — | — | ||||
| GD2 Standard | 440G-T21BGPM-5B | 440G-T21BGPT-5B | — | — | |||||
§ For connector ratings, see page Safety Switches and Connectors.
§ With an 8-pin micro connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Time Delay | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | ||||||||
| MSR127RP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | — | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | — | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Specialty Safety Relays | ||||||||
| MSR178 | 3 N.O. | 2 N.C. | 0.5 s…30 min | Removable | Automatic | 24V AC/DC, 115V AC or 230V AC | MSR178DP | 440R-M23227 |
| CU2 | 2 N.O. | 1 N.C. | 0.1 s…40 min | Fixed | — | 24V AC/DC | CU2 | 440R-S07281 |
| CU3 | 2 N.O. | 1 N.C. | — | Fixed | Automatic/Manual | 110V AC | CU3 | 440R-S35002 |
| Modular Safety Relays | ||||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | — | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | — | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | — | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 8-Pin Micro (M12) | 12-Wire, 12-Pin M23 |
9-Wire, 12-Pin M23§ |
| Cordset | 889D-F8AB-¬ | 889M-F12AH-¬ | 889M-F12X9AE-¬ |
| Patchcord | 889D-F8ABDM-T | 889M-F12AHMU- | — |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
§ The 9-wire cordset can be used only with the TLS3 versions.