Guard Locking Switches

Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Guard Locking Switches > TLS-GD2

TLS-GD2

Introduction Specifications Product Selection Accessories Approximate Dimensions Typical Wiring Diagrams
Typical Wiring Diagrams

Red Switches TLS1 TLS2 TLS3
Contact Configuration Click to enlarge - 440G_T27##_(TLS1-2)_Wiring Click to enlarge - 440G_T27##_(TLS3)_Wiring
Jumper between 12 & 41 Jumper between 12 & 41 and 22 & 51
Contact Action Click to enlarge - 440G-T27##_(TLS1 3NC1NO1PC)_Contact Click to enlarge - 440G-T27##_(TLS2_3NC2NO2P)_Contact Click to enlarge - 440G-T27##_TLS3_(4NC1NO)_Contact
Click to enlarge - ContactActionKey BBM BBM BBM
8-Pin Micro (M12) Click to enlarge - DC Micro 8-Pin Male D_Pin-out (Safety) Click to enlarge - DC Micro 8-Pin Male G_Pin-out (Safety)
No jumper on 12-41. Jumper on 12-41 and 22-51.
12-Pin M23 1 and 3 Solenoid Power 1 and 3 Solenoid Power
Click to enlarge - M23 12-Pin Male_Pinout 4 and 12 Safety A v  4 and 12 Safety A v 
7 and 8 Safety B 7 and 5 Safety B v 
9 and 10 Aux A 9 and 10 Aux A
6 and 11 Solenoid A v  6 and 11 Solenoid A v 
2 and 5 Solenoid B 2 and 8 Solenoid B v 
8-Pin Cordset
889D-F8AB-¬ 
Brown
Blue
Solenoid Power Solenoid Power
Grey
Red
Safety A Safety A & Solenoid A
Yellow
Pink
Safety B Safety B & Solenoid B
White
Green
Solenoid A Solenoid A
12-Pin, 9-Wire Cordset
889M-F12X9AE-¬ 

Pink/Yellow: Not connected
Can not be used. Brown
Blue
Solenoid Power
White
Green
Safety A & Solenoid A
Yellow
Grey
Safety B & Solenoid B
Pink
Red
Aux A
12-Pin, 12-Wire Cordset
889M-F12AH-¬ 
Brown
Grey
Solenoid Power Brown
Grey
Solenoid Power
Pink
Green
Safety A v  Pink
Green
Safety A v 
White
Red/Blue
Safety B White
Red
Safety B v 
Black
Violet
Aux A Black
Violet
Aux A
Grey/Pink
Yellow
Solenoid A v  Grey/Pink
Yellow
Solenoid A v 
Blue
Red
Solenoid B Blue
Red/Blue
Solenoid B v 
 
¬ Replace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths.
v See WARNING notes.

Click to enlarge - WarningExclamation WARNING: To monitor independently the safety contact(s) and the solenoid feedback (TLS 1, 2 and 3):
• The 12-wire cordset 889M-F12AH-¬  must be used
AND
• For the TLS1 and TLS2: the jumper between 12 and 41 must be removed
• For the TLS3: the jumpers between 12 and 41 and 22 and 51 must be removed
  

Click to enlarge - WarningExclamation WARNING: Monitoring of safety contact(s) and the solenoid feedback (in series) is available, when jumpers are in place:
AND
• For the TLS1 and TLS2: by using pins 4 and 6 on the 12-pin, M23 receptacle or Pink and Yellow wires on the
12-wire cordset (889M-F12AH-¬ )
• For the TLS3: by using pins 4 and 6 and pins 7 and 8 on the 12-pin, M23 receptacle or Pink and Yellow and
White and Red/Blue wires on the 12-wire cordset (889M-F12AH-¬ )
  