Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Non-Contact Switches > Ferrogard™ 1, 2, 20 & 21
Ferrogard™ 1, 2, 20 & 21
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions | Typical Wiring Diagrams |
| Safety Ratings | |
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 |
| Safety Classification | Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems |
| Functional Safety Data Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. PFHD: > 3 x 10-7 MTTFd: > 385 years Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics |
| Certifications | CE Marked for all applicable directives and cULus |
| Outputs (Guard Door Closed, Actuator in Place) | |
| Safety Outputs | FRS1: 1 N.C., FRS2: 1 N.C., FRS20: 2 N.C., FRS21: 2 N.C. |
| Auxiliary Outputs | FRS1: None, FRS2: 1 N.O., FRS20: None, FRS21: 1 N.O. |
| Operating Characteristics | |
| Operating Distance, Make [mm (in.)] | Safety: 12 (0.47); Auxiliary: 15 (0.59) |
| Operating Distance, Break [mm (in.)] | Safety: 23 (0.91); Auxiliary: 26 (1.02) |
| Fuses, External | FRS1, 2 & 21: 1.6 A (Bussmann BK/60 A-1.6 A) max. FRS20: 0.4 A (Bussmann BK/60 A-400 mA) max. |
| Environmental | |
| Enclosure Type Rating | IP67 (NEMA 6P) |
| Operating Temperature [C (F)] | -10…+55° (+14…+131°) |
| Relative Humidity | 5…95% |
| Shock | 50 g |
| Vibration | 7 g; 50…200 Hz |
| Radio Frequency | IEC 61000-4-3, IEC 61000-4-6 |
| Physical Characteristics | |
| Actuator/Housing Material | Molded ABS plastic |
| Weight [g (lb)] | FRS 1—Sensor: 35 (0.08)/Actuator: 85 (0.19) FRS 2—Sensor: 40 (0.09)/Actuator: 85 (0.19) FRS 20—Sensor: 43 (0.09)/Actuator: 85 (0.19) FRS 21—Sensor: 43 (0.09)/Actuator: 85 (0.19) |
| Color | Red |
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years |
|