Ferrogard 6, 9. 10, 13, & 14

Click to enlarge - 440N-G020##(6-9-10)_Product


Description

The Ferrogard range of magnetically actuated safety switches offers non-contact reliability together with tolerance to misalignment. They are designed to be installed so that when a guard door is opened, the action of the magnetic actuator being removed from the switch opens the N.C. safety contact which is intended for the isolation of control power to a machine primary control element.

The FRS 6, 9, 10, 13, and 14 sensors and actuators incorporate slim housings to accommodate narrow mounting areas. They are environmentally sealed to IP67 (NEMA 6P), which makes them ideal for wet environments. These Ferrogard switches have two active sensing faces allowing more flexible mounting options.

Unlike some magnetic switches the Ferrogards have protected safety contacts to help ensure that they do not fail to danger.

All Ferrogards have internal non-resettable overload protection on the safety contact. They should be protected by an external fuse rated as shown in the Specifications table.


Features


Specifications

Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
B10d: > 2 x 106 operations at min.
PFHD: > 3 x 10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives and cULus
Outputs (Guard Door Closed, Actuator in Place)
Safety Outputs 1 N.C. 1 N.C.
Auxiliary Outputs 1 N.C.
Operating Characteristics
Operating Distance, Make [mm (in.)] 12 (0.47)
Operating Distance, Break [mm (in.)] 23 (0.91)
Environmental
Enclosure Type Rating IP67 (NEMA 6P)
Operating Temperature [C (F)] -10…+65° (+14…+149°)
Relative Humidity 5…95%
Shock IEC 68-2-27, 30 g, 11 ms
Vibration IEC 68-2-6, 10…55 Hz
Radio Frequency IEC 61000-4-3, IEC 61000-4-6
Physical Characteristics
Actuator/Housing Material Molded ABS plastic
Weight [g (lb)] Sensor/Actuator
FRS 6—28 (0.06)/70 (0.15)
FRS 9—28 (0.06)/70 (0.15)
FRS 10—28 (0.06)/70 (0.15)
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years

Product Selection

Safety Contact Switching Capability Safety Contacts Auxiliary Contacts Housing Material Type Connection Cat. No.
250V AC, 2 A 1 N.C. Red Molded ABS Plastic FRS 6 2 m Cable 440N-G02023
4 m Cable 440N-G02028
6 m Cable 440N-G02032
10 m Cable 440N-G02013
4-Pin Micro QD 440N-G02095
24V DC, 1 A FRS 9 2 m Cable 440N-G02044
4 m Cable 440N-G02075
6 m Cable 440N-G02082
10 m Cable 440N-G02089
4-Pin Micro QD 440N-G02096
110V AC, 3 A FRS 10 2 m Cable 440N-G02045
4 m Cable 440N-G02088
250V AC, 2 A 1 N.C. Stainless Steel FRS 13 2 m Cable 440N-G02154
4 m Cable 440N-G02155
4-Pin Micro QD 440N-G02160
24V DC, 1 A FRS 14 2 m Cable 440N-G02156
4 m Cable 440N-G02157
4-Pin Micro QD 440N-G02161
 
Note: Contacts are described with the guard door closed, that is, actuator in place.

Recommended Logic Interfaces

Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays
MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC MSR127RP/TP 440R-N23135
MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC MSR127RP/TP 440R-N23132
MSR126T 2 N.O. None Fixed Auto./Manual 24V AC/DC MSR126R/T 440R-N23117
MSR30T 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC MSR30RT/RTP 440R-N23198
Modular Safety Relays
MSR210P Base
2 N.C. only
2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit MSR210P 440R-H23176
MSR220P Input Module Removable 24V DC MSR220P 440R-H23178
MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC MSR310P 440R-W23219
MSR320P Input Module 2 PNP Solid State Removable 24V DC from the base unit MSR320P 440R-W23218
  

Note:  For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.


Connection Systems

Description 4-Pin Micro (M12)
Cordset 889D-F4AC-¬ 
Patchcord 889D-F4ACDM-T 
  

¬  Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T  Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Note: For additional information, see Safety Connection Systems.


Accessories

Description Cat. No.
FRS 6, 9, 10 Plastic Replacement Actuator 440N-A02025
FRS 13, 14 Stainless Steel Replacement Actuator 440N-A02165
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

FRS 6, 9, 10

Click to enlarge - 440N-G020##(6-9-10)_Dims


FRS 13, 14

Click to enlarge - 440N-G020##(13-14)_Dims

Typical Wiring Diagrams

  FRS 6, 9, 10 FRS 13, 14
1 N.C. 1 N.C. + 1 N.O.
4-Pin Micro (M12) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out A (Safety) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out A (Safety)
Cordset
889D-F4AC-¬ 
Brown Safety A Safety A
Blue
White Aux A
Black
Cable Version Safety A Brown Brown
Blue Blue
Aux A Black
Grey
 
¬ Replace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths.

External Fuse Safety Contacts

Click to enlarge - WarningExclamation WARNING: All safety contacts fitted with internal non-resettable fuse and must be fused externally as detailed. Click to enlarge - ExtFuseWrngDiag Recommended:
*Bussman BK/GDA-1.6 A
** Bussman BK/GDA-400 mA
***Bussman BK/GDA-2.5 A
    FRS 1, 2, 3, 4, 5, 6, 13, 21 AC AC £ 1.6 A* (F) IEC 60127-2
    FRS 9, 14, 2 DC, 20 DC, 21 DC DC £ 0.4 A** (F) IEC 60127-2
    FRS 10 AC £ 2.5 A*** (F) IEC 60127-2