Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Non-Contact Switches > Ferrogard 6, 9. 10, 13, & 14
Ferrogard 6, 9. 10, 13, & 14
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions | Typical Wiring Diagrams |
| Safety Ratings | ||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 | |
| Safety Classification | Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems | |
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. PFHD: > 3 x 10-7 MTTFd: > 385 years Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics |
|
| Certifications | CE Marked for all applicable directives and cULus | |
| Outputs (Guard Door Closed, Actuator in Place) | ||
| Safety Outputs | 1 N.C. | 1 N.C. |
| Auxiliary Outputs | — | 1 N.C. |
| Operating Characteristics | ||
| Operating Distance, Make [mm (in.)] | 12 (0.47) | |
| Operating Distance, Break [mm (in.)] | 23 (0.91) | |
| Environmental | ||
| Enclosure Type Rating | IP67 (NEMA 6P) | |
| Operating Temperature [C (F)] | -10…+65° (+14…+149°) | |
| Relative Humidity | 5…95% | |
| Shock | IEC 68-2-27, 30 g, 11 ms | |
| Vibration | IEC 68-2-6, 10…55 Hz | |
| Radio Frequency | IEC 61000-4-3, IEC 61000-4-6 | |
| Physical Characteristics | ||
| Actuator/Housing Material | Molded ABS plastic | |
| Weight [g (lb)] | Sensor/Actuator FRS 6—28 (0.06)/70 (0.15) FRS 9—28 (0.06)/70 (0.15) FRS 10—28 (0.06)/70 (0.15) |
|
| Color | Red | |
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years |
||