Non-Contact Switches

Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Non-Contact Switches > Ferrogard 6, 9. 10, 13, & 14

Ferrogard 6, 9. 10, 13, & 14

Introduction Specifications Product Selection Accessories Approximate Dimensions Typical Wiring Diagrams
Typical Wiring Diagrams

  FRS 6, 9, 10 FRS 13, 14
1 N.C. 1 N.C. + 1 N.O.
4-Pin Micro (M12) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out A (Safety) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out A (Safety)
Cordset
889D-F4AC-¬ 
Brown Safety A Safety A
Blue
White Aux A
Black
Cable Version Safety A Brown Brown
Blue Blue
Aux A Black
Grey
 
¬ Replace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths.

External Fuse Safety Contacts

Click to enlarge - WarningExclamation WARNING: All safety contacts fitted with internal non-resettable fuse and must be fused externally as detailed. Click to enlarge - ExtFuseWrngDiag Recommended:
*Bussman BK/GDA-1.6 A
** Bussman BK/GDA-400 mA
***Bussman BK/GDA-2.5 A
    FRS 1, 2, 3, 4, 5, 6, 13, 21 AC AC £ 1.6 A* (F) IEC 60127-2
    FRS 9, 14, 2 DC, 20 DC, 21 DC DC £ 0.4 A** (F) IEC 60127-2
    FRS 10 AC £ 2.5 A*** (F) IEC 60127-2