Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Non-Contact Switches > Ferrogard GD2
Ferrogard GD2
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions | Typical Wiring Diagrams |
| Safety Contact Switching Capability | Safety Contacts | Auxiliary Contacts | Connection | Type | Cat. No. |
| 250V AC, 2 A max. | 2 N.C. | — | 3 m Cable | FRS 20 GD2 | 440N-G02113 |
| 1 N.C. | 1 N.O. | 3 m Cable | FRS 2 GD2 | 440N-G02112 | |
| 2 N.C. | 3 m Cable | FRS 21 GD2 | 440N-G02117 | ||
| 24V DC, 1 A max. | 1 N.C. | 1 N.O. | 3 m Cable | FRS 2 GD2 | 440N-G02118 |
| 10 m Cable | FRS 2 GD2 | 440N-G02147 | |||
| 2 N.C. | — | 3 m Cable | FRS 20 GD2 | 440N-G02119 | |
| 2 N.C. | 1 N.O. | 3 m Cable | FRS 21 GD2 | 440N-G02123 | |
| 6 m Cable | FRS 21 GD2 | 440N-G02143 | |||
| 10 m Cable | FRS 21 GD2 | 440N-G02137 | |||
| 8-Pin Micro (M12) | FRS 21 GD2 | 440N-G02149 | |||
| Note: Contacts are described with the guard door closed, that is, actuator in place. Switch is shipped with complete actuator. | |||||
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30T | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 8-Pin Micro (M12) |
| Cordset | 889D-F8AB-¬ |
| Patchcord | 889D-F8ABDM-T |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Note: For additional information, see Safety Connection Systems.