Ferrogard GS1 & GS2
|
Description
The Ferrogard range of magnetically actuated safety switches offers non-contact reliability together with tolerance to misalignment. They are designed to be installed so that when a guard door is opened, the action of the magnetic actuator being removed from the switch opens the N.C. safety contacts which are intended for the isolation of control power to a machine primary control element.
The GS1 and GS2 are designed for heavy duty applications. The GS1 is housed in a stainless steel or brass housing. The GS2 offers the same characteristic as the GS1, but in an Ex Range housing for hazardous locations.
Unlike some magnetic switches the Ferrogards have protected safety contacts to help ensure that they do not fail to danger.
All Ferrogards have internal non-resettable overload protection on the safety contact. They should be protected by an external fuse rated as shown in the Specifications table.
See Other Safety Related Products for more information on the Ex Range version of the Ferrogard GS2.
Features
- Non-contact actuation
- High tolerance to misalignment
- High switching current (2 A AC)
- Metal housings (IP68)
- Ex Range version available
Specifications
| Safety Ratings | |
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 |
| Safety Classification | Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems |
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. PFHD: > 3 x 10-7 MTTFd: > 385 years Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics |
| Certifications | GS1 & GS2 - CE Marked for all applicable directives and cULus GS2 Ex - EExd IIC T6 Baseefa |
| Outputs (Guard Door Closed, Actuator in Place) | |
| Safety Outputs | 1 N.C. |
| Auxiliary Outputs | — |
| Operating Characteristics | |
| Operating Distance, Make [mm (in.)] | GS1: 12 (0.47); GS2: 15 (0.59) |
| Operating Distance, Break [mm (in.)] | GS1: 23 (0.91); GS2: 26 (1.02) |
| Environmental | |
| Enclosure Type Rating | IP68 (NEMA 6P) |
| Operating Temperature [C (F)] | GS1: -25…+125° (-13…+257°) GS2: -40…+60° (-40…146°) |
| Relative Humidity | 5…95% |
| Shock | IEC 68-2-27, 30 g, 11 ms |
| Vibration | IEC 68-2-6, 10…55 Hz |
| Radio Frequency | IEC 61000-4-3, IEC 61000-4-6 |
| Physical Characteristics | |
| Housing Material | Stainless Steel or Brass |
| Weight [g (lb)] | GS1 Brass: 381 (0.84) GS1 Steel: 388 (0.86) Actuator: 116 (0.26) |
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years |
|
Product Selection
| Safety Contact Switching Capability | Safety Contacts | Auxiliary Contacts | Connection | Housing Material | Type | Cat. No. |
| 250V AC, 2 A | 1 N.C. | None | 2 m Cable | Brass | GS 1 | 440N-G02048 |
| Stainless Steel | 440N-G02049 | |||||
| 3 m Cable | Brass | GS2-Ex (brass) | 440N-H02046 | |||
| Stainless Steel | GS2-Ex (stainless steel) | 440N-H02047 | ||||
| Note: Contacts are described with the guard door closed, that is, actuator in place. Switch is shipped with complete actuator. | ||||||
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30T | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Accessories
| Description | Used with | Cat. No. |
| Actuator, Alnico | Brass Switch | 440N-A02056 |
| Actuator, Epoxy-painted | Stainless Steel | 440N-A02057 |
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|
Typical Wiring Diagrams
|
External Fuse Safety Contacts
|
WARNING: All safety contacts fitted with internal non-resettable fuse and must be fused externally as detailed. | |
| GS1 GS2 |
AC £ 1.6 A* (F) IEC 60127-2 | |