Ferrogard GS1 & GS2

Click to enlarge - 440N-#020##(GS1-GS2)_Product


Description

The Ferrogard range of magnetically actuated safety switches offers non-contact reliability together with tolerance to misalignment. They are designed to be installed so that when a guard door is opened, the action of the magnetic actuator being removed from the switch opens the N.C. safety contacts which are intended for the isolation of control power to a machine primary control element.

The GS1 and GS2 are designed for heavy duty applications. The GS1 is housed in a stainless steel or brass housing. The GS2 offers the same characteristic as the GS1, but in an Ex Range housing for hazardous locations.

Unlike some magnetic switches the Ferrogards have protected safety contacts to help ensure that they do not fail to danger.

All Ferrogards have internal non-resettable overload protection on the safety contact. They should be protected by an external fuse rated as shown in the Specifications table.

See Other Safety Related Products for more information on the Ex Range version of the Ferrogard GS2.


Features


Specifications

Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
B10d: > 2 x 106 operations at min.
PFHD: > 3 x 10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications GS1 & GS2 - CE Marked for all applicable directives and cULus
GS2 Ex - EExd IIC T6 Baseefa
Outputs (Guard Door Closed, Actuator in Place)
Safety Outputs 1 N.C.
Auxiliary Outputs
Operating Characteristics
Operating Distance, Make [mm (in.)] GS1: 12 (0.47); GS2: 15 (0.59)
Operating Distance, Break [mm (in.)] GS1: 23 (0.91); GS2: 26 (1.02)
Environmental
Enclosure Type Rating IP68 (NEMA 6P)
Operating Temperature [C (F)] GS1: -25…+125° (-13…+257°)
GS2: -40…+60° (-40…146°)
Relative Humidity 5…95%
Shock IEC 68-2-27, 30 g, 11 ms
Vibration IEC 68-2-6, 10…55 Hz
Radio Frequency IEC 61000-4-3, IEC 61000-4-6
Physical Characteristics
Housing Material Stainless Steel or Brass
Weight [g (lb)] GS1 Brass: 381 (0.84)
GS1 Steel: 388 (0.86)
Actuator: 116 (0.26)
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years

Product Selection

Safety Contact Switching Capability Safety Contacts Auxiliary Contacts Connection Housing Material Type Cat. No.
250V AC, 2 A 1 N.C. None 2 m Cable Brass GS 1 440N-G02048
Stainless Steel 440N-G02049
3 m Cable Brass GS2-Ex (brass) 440N-H02046
Stainless Steel GS2-Ex (stainless steel) 440N-H02047
  
Note: Contacts are described with the guard door closed, that is, actuator in place. Switch is shipped with complete actuator.

Recommended Logic Interfaces

Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays
MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC MSR127RP/TP 440R-N23135
MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC MSR127RP/TP 440R-N23132
MSR126T 2 N.O. None Fixed Auto./Manual 24V AC/DC MSR126R/T 440R-N23117
MSR30T 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC MSR30RT/RTP 440R-N23198
Modular Safety Relays
MSR210P Base
2 N.C. only
2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit MSR210P 440R-H23176
MSR220P Input Module Removable 24V DC MSR220P 440R-H23178
MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC MSR310P 440R-W23219
MSR320P Input Module 2 PNP Solid State Removable 24V DC from the base unit MSR320P 440R-W23218
  

Note:  For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.


Accessories

Description Used with Cat. No.
Actuator, Alnico Brass Switch 440N-A02056
Actuator, Epoxy-painted Stainless Steel 440N-A02057
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440N-#020##(GS1-GS2)_Dims

Typical Wiring Diagrams

Click to enlarge - 440N-#020##(GS1-GS2)_Wiring


External Fuse Safety Contacts

Click to enlarge - Warning-Exclamation_GS WARNING: All safety contacts fitted with internal non-resettable fuse and must be fused externally as detailed.
  GS1
GS2
AC £ 1.6 A* (F) IEC 60127-2
 
Recommended:
*Bussman BK/GDA-1.6 A