Specifications

Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
B10d: > 2 x 106 operations at min.
PFHD: > 3 x 10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications GS1 & GS2 - CE Marked for all applicable directives and cULus
GS2 Ex - EExd IIC T6 Baseefa
Outputs (Guard Door Closed, Actuator in Place)
Safety Outputs 1 N.C.
Auxiliary Outputs
Operating Characteristics
Operating Distance, Make [mm (in.)] GS1: 12 (0.47); GS2: 15 (0.59)
Operating Distance, Break [mm (in.)] GS1: 23 (0.91); GS2: 26 (1.02)
Environmental
Enclosure Type Rating IP68 (NEMA 6P)
Operating Temperature [C (F)] GS1: -25…+125° (-13…+257°)
GS2: -40…+60° (-40…146°)
Relative Humidity 5…95%
Shock IEC 68-2-27, 30 g, 11 ms
Vibration IEC 68-2-6, 10…55 Hz
Radio Frequency IEC 61000-4-3, IEC 61000-4-6
Physical Characteristics
Housing Material Stainless Steel or Brass
Weight [g (lb)] GS1 Brass: 381 (0.84)
GS1 Steel: 388 (0.86)
Actuator: 116 (0.26)
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year