Non-Contact Switches

Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Non-Contact Switches > SensaGuard™

SensaGuard™

Introduction Specifications Product Selection Accessories Approximate Dimensions—mm (inches) Typical Wiring Diagrams Application Wiring Examples
Specifications

Safety Ratings
Standards IEC 60947-5-3, IEC 61508, EN 954
Safety Classification Cat. 4/SIL3
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
PFHD: > 1.12 x 109
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE marked for all applicable directives, cULus (UL 508), and TÜV
Outputs (Guard Door Closed, Actuator in Place)
Safety Outputs 2 x PNP, 0.2 A, max.; Status: ON (+24V DC)
Auxiliary Outputs 1 x PNP, 0.2 A max.; Status: OFF (0V DC)
Operating Characteristics
Sensing Distance (Assure) 18 mm Plastic Barrel/18 mm Target 15 mm (0.59 in)
18 mm Plastic Barrel/30 mm Target 25 mm (0.98 in)
18 mm Stainless Steel Barrel/Standard Target 10 mm (0.39 in)
Large Rectangular Flat Pack with Standard Target 15 mm (0.59 in)
Misalignment Tolerance, Min See misalignment curve.
Repeat Accuracy 10% of Sensing Range
Output Current, Max. 200 mA (all outputs)
Operating Voltage 24V DC, +10%/-15%
Class 2 SELV power supply
Current Consumption 50 mA
Frequency of Operating Cycle 1 Hz
Response Time (Off) 54 ms
Environmental
Enclosure Type Rating NEMA 3, 4X, 12, 13, IP 69K
Operating Temperature [C (F)] -10…+55° (+14…+131°)
Relative Humidity 5…95%
Shock IEC68-2-27 30 g, 11 ms
Vibration IEC 68-2-6 10…55 Hz
Radio Frequency IEC 61000-4-3, IEC 61000-4-6
Physical Characteristics
Housing Material Valox® DR 48
Actuator Material Valox® DR 48
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 30 years