  MC1 MC2
Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC60947-5-1, IEC/EN60947-5-3, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 Device per EN 954-1; Dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
B10d: > 2 x 106 operations at min.
PFHD: > 3 x 10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives, cULus, and TÜV
Outputs (Guard Door Closed, Actuator in Place)
Safety Outputs 2 N.C. REEDS 2 N.C. Solid-State Relays
Auxiliary Outputs 1 x PNP, 0.2 A max.; Status: OFF (0V DC)
Operating Characteristics
Operating Distance, Make [mm (in.)] 8 (0.3) 10 (0.39)
Operating Distance, Break [mm (in.)] 15 (0.59) 25 (0.98)
Misalignment Tolerance, Min See Misalignment Wire
Repeat Accuracy 10% of Sensing Range
Output Current, Max. 200 mA 200 mA
Switching Current @ Voltage, Max. 24V DC @ 200 mA 24V DC @ 200 mA +10%/-15%
Operating Voltage/Power Supply 24V DC, +10%/-15%/50 mA max./Class 2 SELV
Frequency of Operating Cycle 1 Hz 1 Hz
Environmental
Enclosure Type Rating IP67 (NEMA 6P) IP 69K
Operating Temperature [C (F)] -10…+55° (+14…+131°)
Relative Humidity 5…95%
Shock IEC 68-2, 27, 30 g, 11 ms
Vibration IEC 68-2-6, 10…55 Hz
Radio Frequency IEC 61000-4-3, IEC 61000-4-6
Physical Characteristics
Housing Material Molded ABS Ultrador
Actuator Material Molded ABS Ultrador
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year