Catalogs > Safety Products Catalog > Safety Switches > Interlock Switches > Hinge Switches > Rotacam™
Rotacam™
Specifications| Safety Ratings | |||||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 | ||||
| Safety Classification | Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems | ||||
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. load PFHD: < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
||||
| Certifications | CE Marked for all applicable directives, cULus, SUVA, and TÜV | ||||
| Outputs | |||||
| Safety Contacts T | 2 N.C. direct opening action | ||||
| Auxiliary Contacts | 1 N.O. | ||||
| Shaft Rotation for Contact Operation | 11° maximum; 5° minimum, (adjustable) | ||||
| Thermal CurrentIlth | 10 A | ||||
| Rated Insulation Voltage | (Ui) 500V | ||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | ||||
| Utilization Category | |||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V |
| (le) | 1.2 A | 1.4 A | 3 A | 6 A | |
| DC-13 | (Ue) | 24V | |||
| (le) | 2 A | ||||
| Operating Characteristics | |||||
| Break Contact Force, Min. | 12 cNm (torque on shaft) | ||||
| Actuation Speed, Max. | 160 mm (6.29 in.)/s | ||||
| Actuation Frequency, Max. | 1 cycle/s | ||||
| Operating Life @ 100 mA load | >1,000,000 operations | ||||
| Environmental | |||||
| Enclosure Type Rating | IP66 | ||||
| Operating Temperature [C (F)] | -20…+80° (-4…176°) | ||||
| Physical Characteristics | |||||
| Housing Material | Heavy-duty die-cast alloy | ||||
| Shaft Material | Stainless Steel | ||||
| Weight [g (lb)] | 420 (0.926) | ||||
| Color | Red | ||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
|||||