Safety Mats

Catalogs > Safety Products Catalog > Presence Sensing Safety Devices > Safety Mats > MatGuard™ Mats

MatGuard™ Mats

Introduction Specifications Product Selection—Standard Mats Examples Product Selection—Configurable Mats
Product Selection, Trim Options Accessories Approximate Dimensions—mm (inches) Connectivity Typical Wiring Diagrams
Connectivity

Two-Wire Cable Option

Click to enlarge - 440F-M##BYNN (Mat Cross-Section)_Diagram


4-Pin Micro M12 Connector Option—mm (in)

Click to enlarge - 889D-F#A#_Dims Checkered Rib Side of Mat
Click to enlarge - DC Micro 4 (5)-Pin Female ST_Pinout
Straight Male Straight Rib Side of Mat

Connection Cables

Cable Exit
Configuration Code
Description Compatibility Connector Wire Color Circuit
A Two 4.5 m (15 ft) 2-wire cables—exit out the A corners Safety Relays Click to enlarge - 440F-M##BYNN (Two-Wire)_Diagram_GS Black
Black
N.C.
B Two 4.5 m (15 ft) 2-wire cables—exit out the B corners Safety Relays White
White
N.C.
C One 9.1 m (30 ft) 4-wire cable with M12 male connector exits out of upper left corner Mat Managers Click to enlarge - DC Micro 4 (5)-Pin Female ST_Pinout 1 Brown
2 White
N.C.
3 Blue
4 Black
N.C.
D One 9.1 m (30 ft) 4-wire cable without connector exits out of upper left corner Safety Relays 1 Brown
2 White
N.C.
3 Blue
4 Black
N.C.
F One 0.76 m (2.5 ft) 4-wire cable with M12 male connector exits out of upper left corner Mat Managers 1 Brown
2 White
N.C.
3 Blue
4 Black
N.C.
G One 9.1 m (30 ft) 4-wire cable with M12 male connector exits out of upper left corner Distribution Block
(2 N.C.) 898D-4*LT-DM4
1 Brown
3 Blue
N.C.
2 White
4 Black
N.C.
H One 9.1 m (30 ft) 5-wire cable with M12 male connector exits out of upper left corner ArmorBlock Guard I/O Click to enlarge - DC Micro (2-5)-Pin Male RT_Pinout 1 Brown
2 White
N.C.
4 Black
5 Grey
N.C.
 

Connection to Logic Interfaces

Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays
MSR131RTP 3 N.O. 2 N.C., 2 PNP Solid State Removable (Screw) Auto./Manual or Monitored Manual 24V AC/DC Description 440R-C23139
MSR30RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC Description 440R-N23198
Specialty Safety Relays
MSR23M 2 N.O. 1 N.C. Fixed Automatic/Manual Monitored Manual 24V AC/DC Description 440R-P23073
Mat Controller 2 N.O. 1 N.C. Fixed Automatic/Manual Monitored Manual 24V AC/DC or 110/230V AC Description 440F-C4000S
Mat Manager 2 N.O. 1 N.C. Fixed Auto./Manual Monitored Manual 24V DC Description 440F-C28011
Modular Safety Relays
MSR210P Base (2 N.C.) 2 N.O. 1 N.C. and 2 PNP Solid State and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit Description 440R-H23176
MSR220P Input Module (all) Removable 24V DC Description 440R-H23178
MSR320P Input Module (all) 2 PNP Solid State Removable 24V DC from the base unit Description 440R-W23218
  
Note: For additional Safety Relays connectivity, see the Logic section of this catalog.
For additional Safety I/O connectivity, see the Safety I/O section of this catalog.
For Application and wiring diagrams, see the Applications section of this catalog.

Connection Systems (4-Pin QD only)

Connection 4-Pin 6-Pin
Cordset 889D-F4AC-¬  889R-F6ECRM-¬ 
Patchcord 889D-F4ACDM-T  889D-F5ACDM-T 
Distribution Box 898D-4‡ LT-DM4 898R-P68MT-A5
Shorting Plug 898D-41LU-DM 898R-61MU-RM
T-Port 898D-43LY-D4 NA
  

¬  Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T  Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.