Specifications| Safety Ratings | |
| Standards | IEC 61496, Parts 1 & 2 |
| Safety Classification | Type 4, IEC 61496; SIL 3 (IEC 61508); SIL CL3 (IEC 62061); Category 4 (EN ISO 13849); PLe (EN ISO 13849); B10d parameter: 1 x 106 switching cycles (@ DC-13, 24V, 0.6 A); 2 x 105 switching cycles (@ DC-13, 24V, 1.5 A) PFHd: 4.0 x 10-9; Mission time: 20 years |
| Certifications | CE Marked for all applicable directives and BG |
| Power Supply | |
| Input Power, Max. | 24V DC ±20% |
| Maximum Residual Ripple | 5% of Uv, max. |
| Power Consumption | 24V DC 8 W max. |
| Outputs | |
| Safety Outputs | 2 N.O. Relays |
| Switching Current @ Voltage, Min. | 0.02 A to 2 A |
| Operating Characteristics | |
| Response Time | < 22 ms |
| Status Indicators | On state, Off state, alignment |
| Beam Diameter | 23 mm (0.91 in.) |
| Scanning Range | 0.5…20 m (1.64…65.5) or 15…70 m (49.2…300 ft) |
| Synchronization | Optical |
| Wavelength | 950 nm |
| Environmental | |
| Enclosure Type Rating | IP67 (EN 60529) |
| Relative Humidity | 15…95%, noncondensing |
| Operating Temperature [C (F)] | -25…55° (-13…131°) |
| Vibration | 5 g, 10…55 Hz per IEC 60068-2.6 |
| Shock | 10 g, 16 ms per IEC 60068-2.29 |
| Physical Characteristics | |
| Front Window | Heated |
| Weight | Transmitter unit: approx. 0.9…1.3 kg Receiver unit: approx. 1…1.4 |
| Housing Cross Section | 50 x 156 x 116 mm (1.96 x 6.14 x 4.56 in.) |
| Connection Type | Terminal chamber with cable gland (PG13.5 thread) |
| Cable Length | 50 m (164 ft) max. |
| Note: The external power supply must be capable of buffering brief power failures of 20 ms as specified in IEC 60204-1. | |