Catalogs > Safety Products Catalog > Presence Sensing Safety Devices > Opto-electronics > Safety Light Curtains > POC Type 4 GuardShield Safe 4
POC Type 4 GuardShield Safe 4
| Introduction | Applications | Specifications | Product Selection | Approximate Dimensions | Wiring Diagram for Connection to MSR126 |
Standard System
The Allen-Bradley Guardmaster GuardShield Safe 4 safety light curtains are offered in 14 mm and 30 mm resolutions, are ordered as pairs—transmitter and receiver—and are shipped under one cat. no. Each GuardShield Safe 4 pair is shipped with standard mounting brackets. After selecting the appropriate Safe 4 protected height and resolution, ensure that the appropriate cordsets, interfaces, and accessories are ordered.
| Protected Height [mm (in.)] | 14 mm (0.55 in.) Number of Beams |
30 mm (1.18 in.) Number of Beams |
Pair Weight [kg (lbs)] | Cat. No. | |
| 14 mm (0.55 in.) | 30 mm (1.18 in.) | ||||
| 120 (4.7) | 16 | 8 | 1.0 (2.2) | 445L-P4L0120YD | 445L-P4S0120YD |
| 240 (9.4) | 32 | 16 | 1.4 (3.1) | 445L-P4L0240YD | 445L-P4S0240YD |
| 360 (14.2) | 48 | 94 | 1.8 (4.0) | 445L-P4L0360YD | 445L-P4S0360YD |
| 480 (19.9) | 64 | 94 | 2.2 (4.9) | 445L-P4L0480YD | 445L-P4S0480YD |
| 600 (23.6) | 80 | 94 | 2.6 (5.7) | 445L-P4L0600YD | 445L-P4S0600YD |
| 720 (28.3) | 96 | 94 | 3.0 (6.6) | 445L-P4L0720YD | 445L-P4S0720YD |
| 840 (33.1) | 112 | 94 | 3.5 (7.7) | 445L-P4L0840YD | 445L-P4S0840YD |
| 960 (37.8) | 128 | 94 | 4.0 (8.8) | 445L-P4L0960YD | 445L-P4S0960YD |
| 1080 (42.5) | 144 | 94 | 4.0 (8.8) | 445L-P4L1080YD | 445L-P4S1080YD |
| 1200 (47.2) | 160 | 94 | 4.5 (9.9) | 445L-P4L1200YD | 445L-P4S1200YD |
| 1320 (52.0) | 176 | 94 | 5.0 (11.0) | 445L-P4L1320YD | 445L-P4S1320YD |
| 1440 (56.7) | 172 | 94 | 5.5 (12.1) | 445L-P4L1440YD | 445L-P4S1440YD |
| 1560 (61.4) | 188 | 102 | 6.0 (13.2) | 445L-P4L1560YD | 445L-P4S1560YD |
| 1680 (66.1) | 204 | 102 | 6.5 (14.3) | 445L-P4L1680YD | 445L-P4S1680YD |
| 1800(70.9) | 220 | 110 | 7.0 (15.4) | 445L-P4L1800YD | 445L-P4S1800YD |
| 1920 (75.6) | 236 | 118 | 7.5 (16.5) | 445L-P4L1920YD | 445L-P4S1920YD |
| Note: The cat. nos. listed above are pair cat. nos., to specify a transmitter or receiver only, replace the "P" in the cat. no. with a "T" for transmitter or an "R" for receiver. | |||||
Required Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays for 2 N.C. Contact Switch | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126 | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220 Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
| Muting Modules | |||||||
| MSR22LM | 2 N.O. | 1 N.C. | Removable | Auto./Manual | 24V DC | MSR22LM | 440R-P23071 |
| MSR42 (requires optical interface to configure 445L-AF6150) |
2 PNP | 2 PNP, configurable | Removable | Auto./manual or manual monitored | 24V DC | MSR42 | 440R-P226AGS-NNR |
Cordsets—Transmitters and receivers both use 5-pin M12 cordsets
Note: Unshielded cordsets are most commonly used for safety light curtains, however, shielded cordsets are also offered to increase immunity to electrical interference.
Cordsets Approximate Dimensions [mm (in.)]
Dimensions are not intended to be used for installation purposes.
|
| Straight Female |
Optional Accessories
Corner Mirror for Multi-Sided Guarding
Specially constructed glass mirrors for 2- and 3-sided safeguarding applications.
Note: Each mirror reduces maximum scan range by approximately 15% per mirror.