120V AC Power Supply and Safety Relay

Click to enlarge - 440L-M8400-500_Product


Description

The Allen-Bradley Guardmaster 120V AC interface box consists of a NEMA 4 rated lockable metal enclosure, a DIN mount 3 A, 24V DC power supply and either a single or dual 22.5 mm safety relay(s).

The single safety relay module provides three N.O. safety and one N.C. auxiliary (non-safety) “potential free” relay outputs. The dual safety relay configuration allows two pairs of safety light curtains to independently control one or two machines.

The safety relay(s) can be configured for manual reset or automatic reset. The resetting function can be through the key switch mounted on the front cover of the interface box.

Pre-punched holes located on the bottom of the enclosure allow for easy wiring of the system.


Specifications

Safety Ratings
Safety Classification Nonsafety Rated
Power Supply
Input Power, Max. 120/230V AC
Power Consumption 2 W/4 W
Outputs
Safety Outputs 2 N.O. or 4 N.O.
Auxiliary Outputs 1 N.C. or 2 N.C. Nonsafety
Switching Current @ Voltage, Min. 10 mA @ 10V
Operating Characteristics
Response Time 15 ms
Status Indicators Power = Green
K1 = Green if Closed.
K2 = Green if Closed.
Recovery Time 100 ms
Electrical Life 222V AC/4 A/880V A cosf = 0.35 - 100,000 operations
Mechanical Life 2,000,000 operations
Operating Frequency 1200 cycles/hour, max.
Environmental
Enclosure Type Rating IP65 (NEMA 4)
Relative Humidity 90%
Operating Temperature [C (F)] -5…55° (23…131°)
Vibration 0.35 mm, 10…55 Hz
Shock 10 g, 16 ms, 100 shocks
Physical Characteristics
Weight [kg (lb)] 440L-M8400: 4.87 (10.75)
440L-M8500: /5.1 (11.25)
 

Product Selection

Safety Outputs Auxiliary Outputs Power Supply Output Cat. No.
2 N.O. 1 N.C. nonsafety 120V AC/230V DC 440L-M8400
4 N.O. 2 N.C. nonsafety 120V AC/230V DC 440L-M8500
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 442L-M8400-500_Dims

Typical Wiring Diagram

M8400 Single Relay

Wiring diagram is not intended to be used for installation purposes.

Click to enlarge - 442L-M8400-500_Wiring01


Typical Wiring Diagram

M8500 Dual Relay

Wiring diagram is not intended to be used for installation purposes.

Click to enlarge - 442L-M8400-500_Wiring02