Catalogs > Safety Products Catalog > Presence Sensing Safety Devices > Selection Criteria
Selection Criteria
| Selection Criteria | Selection Tips | Selection Navigator | Technology Overview | Technology Overview (continued) |
| GuardShield Light Curtain | Profile Size [mm] | Type According to IEC 61496 | Finger (14 mm) | Hand (30 mm) | Full Body | Protective Height [mm] | Range | Response Time | IP Rating | Integrated Laser Alignment |
| Standard | 40 x 50 | Type 4 | Yes | Yes | NA | 160…1760 | 14 mm…7 m 30 mm…16 m |
20…30 ms | IP65 (IP67) | Optional/Yes |
| Safe 4 | 30 x 40 | 120…1920 | 14 mm…9 m 30 mm…18 m |
14 mm: 11…90 ms 30 mm: 8…48 ms |
IP65 | Yes | ||||
| Micro 400 | 15 x 20 | 150…1200 | 5 m | 14 mm: 15…42 ms 30 mm: 13…24 ms |
Micro 400 IP54 (IP69K) MSR4x IP20 |
NA | ||||
| PAC | 40 x 50 | NA | NA | 2 and 3 beams | 2 beams: 520 3 beams: 820 |
16 m | 20 ms | IP65 | Optional/Yes | |
| Safe 4 PAC | 30 x 40 | 2 beams: 600 3 beams: 840 |
5…30 m | 2 beams: 11 ms 3 beams: 14 ms |
Yes | |||||
| Type 2 |
40 x 50 | Type 2 | Yes | NA | 160…1760 | 16 m | 20 ms | NA | ||
| Safe 2 | 30 x 40 | 120…1920 | 18 m | 14 mm: 11…90 ms 30 mm: 8…48 ms |
Yes | |||||
| Integrated Controller | Operating Temperature [C (F)] | Beam Coding | Blanking | EDM | Aux. Output | Cascadable | Muting | Configuration | PL/SIL CL | GuardShield Light Curtain |
| Yes | -10…55° (14…131°) | Yes | Yes | Yes | 1 PNP 0.5 A max. | Yes | Yes with MSR42 or MSR22LM | DIP Switch | PLe/SIL CL3 | Standard |
| 0…55° (32…131°) | NA | NA | NA | NA | NA | NA | Safe 4 |
|||
| Requires MSR41 or MSR42 | Yes with MSR42 | Yes with MSR42 | MSR41: 2 PNP 0.1 A max. MSR42: 2 PNP config. |
Yes | Yes with MSR42 | MSR42 Wiring or Software | Micro 400 | |||
| Yes | -10…55° (14…131°) | Yes | NA | Yes | 1 PNP 0.5 A max. | NA | Yes with MSR42 or MSR22LM | DIP Switch | PAC | |
| 0…55° (32…131°) | NA | NA | NA | NA | Safe 4 PAC | |||||
| -10…55° (14…131°) | Factory Option | 1 PNP 0.5 A max. | Factory | Pld/SIL CL2 | Type 2 | |||||
| 0…55° (32…131°) | NA | NA | NA | Safe 2 | ||||||