30 mm NEMA

Click to enlarge - 10_50_800T


Click to enlarge - 10_50_800H


Description

The Bulletin 800T and 800H 30.5 mm Emergency Stop devices provide increased reliability. E-stops with normally closed late break contacts comply with EN418 and IEC 947‑5‑5 standards. This means the operator will latch when actuated before the contacts will change state.

Application flexibility is offered with 2‑position push-pull or 2‑position push-pull/twist release configurations. Non-illuminated and illuminated operator options are available. Contact block versions are also available that provide IP2X finger-safe protection.

Rockwell Automation also offers Self-Monitoring™ contact blocks (SMCB) which feature enhanced E-stop safety for critical process control applications. The SMCB monitors whether or not it is properly installed on the operator so that the normally closed contacts will open when the E-stop is actuated. If the SMCB is separated from the operator for any reason, the controlled circuit will automatically open.


Features


Standards Compliance

UL 508

CCC


Certifications

UL Listed
(File No. E14840, E10314
Guide No. NKCR, NOIV)

CSA Certified
(File No. LR1234, LR11924)

CSA C22.2, No. 14

EN/IEC: 60947-5-1


Specifications

Electrical Ratings
Contact ratings Refer to the contact ratings tables below.
Dielectric strength 2200V for one minute, 1300V for one minute (Logic Reed)
Electrical design life cycles 1 000 000 at max. rated load, 200 000 at max. rated load (Logic Reed)
Mechanical Ratings
Vibration 10…2000 Hz 1.52 mm displacement (peak-to-peak) max./10 G max. (except Logic Reed)
Shock 1/2 cycle sine wave for 11 ms ³ 25 G (contact fragility) and no damage at 100 G
Degree of protection Type 1/4/12/13 (Bul. 800T); Type 1/4/4X/12/13 (Bul. 800H); EN/IEC 60529 IP66/65
Mechanical design life cycles
(Push-pull/twist-to-release)
250 000 min.
Contact operation Shallow, mini, and low voltage contact blocks: Slow, double make and break
Logic Reed and sealed switch contact blocks: Single break magnetic
Wire gauge/Terminal screw torque #18…12 AWG / 6…8 lbin
Typical operating forces  
2-position push-pull 7.5 lbs max. push or pull
Twist-to-release or push-pull 9 lbs max. push or pull 30 in oz. max. twist, 6 in oz. minimum return
Contact blocks Standard 1 lb
Logic Reed 1 lb max.
Sealed switch 3 lbs max. at 0.205 in plunger travel
Stackable sealed switch 1 lb max.
Environment
Temperature range Operating –40…+131 °F (–40…+55 °C)
Storage –40…+185 °F (–40…+85 °C)
Note:Operating temperatures below freezing are based on the absence of moisture and liquids. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for use in lower temperature applications.
Humidity 50…95% RH from 77…140 °F (25…60 °C) per Procedure IV of MIL-STD-BIOC, Method 507.1 cycling test
  

Standard Contact Ratings

Minimum: 24V 24 mA

Maximum thermal continuous current Ith 10 A AC/2.5 A DC. Bulletin 800T and 800H units with Cat. No. 800T-XA contacts have ratings as follows:


Max. Opertnl.
Volts Ue
Utilization Category Rated Operational Currents
IEC NEMA Volts Ue Make Break
AC 600 AC-15 A600 120…600
72…120
24…72
7200VA
60 A
60 A
720VA
720VA
10 A
DC 600 DC-13 Q600 28…600
24…28‡ 
69VA
2.5 A
  
‡ For applications below 24V/24 mA, PenTUFF™ or Logic Reed contacts are recommended.

Product Selection

2-Position Push-Pull and Push-Pull/Twist Release, Non-Illuminated

Note: A jumbo or large legend plate is recommended, if space allows.

Click to enlarge - 800T_800H-1_4-1      Click to enlarge - 800T_800H-1_4-2      Click to enlarge - 800T_800H-1_4-3
2-Position Push-Pull
Cat. No. 800T-FX6D4
     2-Position Push-Pull / Twist
Cat. No. 800T-FXT6D4
     2-Position Push-Pull / Twist
Cat. No. 800H-FRXT6D4

Contact Type Operator Position Button Color Type 4/13 Type 4/4X/13
Click to enlarge - 800T_800H-1_4-4 Click to enlarge - 800T_800H-1_4-5 Push-Pull Push-Pull/Twist
Release
Push-Pull/Twist
Release
Out In Cat. No. Cat. No. Cat. No.
Click to enlarge - 800T_800H-1_3-9 N.C.L.B.⋆  X O Red 800T-FX6D4 800T-FXT6D4 800H-FRXT6D4
Click to enlarge - 800T_800H-1_3-4 N.O. - N.C.L.B.⋆  O
X
X
O
Red 800T-FX6A1 800T-FXT6A1 800H-FRXT6A1
Click to enlarge - 800T_800H-1_4-8 N.C.L.B. - N.C.L.B.⋆  X
X
O
O
Red 800T-FX6A5 800T-FXT6A5 800H-FRXT6A5
Click to enlarge - 800T_800H-1_4-9 S.M.C.B.⋆ ‡  X O Red 800TC-FX6D4S 800TC-FXT6D4S 800HC-FRXT6D4S
Click to enlarge - 800t_800H-1_4-10 N.O. - S.M.C.B.⋆ ‡  O
X
X
O
Red 800TC-FX6A1S 800TC-FXT6A1S 800HC-FRXT6A1S
Click to enlarge - 800t_800h-1_4-11 S.M.C.B. - S.M.C.B⋆ ‡  X
X
O
O
Red 800TC-FX6A5S 800TC-FXT6A5S 800HC-FRXT6A5S
  
Note:X = Closed/O = Open
Note:Emergency stop push buttons are compliant with EN 418 and EN/IEC 60947-5-5 Standards when using N.C.L.B. contact blocks.
Note:These caps are only available in plastic.
    
⋆ Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs.
‡ The Self Monitoring Contact Block (S.M.C.B.) is composed of a N.C.L.B. contact wired in series with a N.O. monitoring contact. The N.O. monitoring contact automatically closes when the S.M.C.B. is properly installed onto the E-stop operator. If the S.M.C.B. is separated from the E-stop operator, the N.O. monitoring contact will automatically open.

2-Position Push-Pull and Push-Pull/Twist Release Units, Illuminated

Note: A jumbo or large legend plate is recommended, if space allows.

Click to enlarge - 800T_800H-1_5-1      Click to enlarge - 800T_800H-1_5-2      Click to enlarge - 800T_800H-1_5-3
Illuminated 2-Position
Push-Pull
Cat. No. 800T-FXP16RA1
     Illuminated 2-Position
Push-Pull/Twist
Cat. No. 800T-FXTP16RA1
     Illuminated 2-Position
Push-Pull/Twist
Cat. No. 800H-FRXTP16RA1

Type Lamp Type Volts Color Contacts Operator Position Type 4/13 Type 4/4X/13
Click to enlarge - 800T_800H-1_4-4 Click to enlarge - 800T_800H-1_4-5 Push-Pull
Release
Push-Pull/Twist
Release
Push-Pull/Twist
Release
Maintained Maintained
Out In Cat. No. Cat. No. Cat. No.
Full Voltage Incandescent 24V AC/DC Red N.O. -
N.C.L.B.
⋆ § 
O
X
X
O
800T-FXQ24RA1 800T-FXTQ24RA1 800H-FRXTQ24RA1
LED 120V AC 800T-FXQH10RA1 800T-FXTQH10RA1 800H-FRXTQH10RA1
24V AC/DC 800T-FXQH24RA1 800T-FXTQH24RA1 800H-FRXTQH24RA1
Transformer Incandescent 120V AC Red N.O. -
N.C.L.B.
⋆ § 
O
X
X
O
800T-FXP16RA1 800T-FXTP16RA1 800H-FRXTP16RA1
240V AC 800T-FXP26RA1 800T-FXTP26RA1 800H-FRXTP26RA1
LED 120V AC 800T-FXPH16RA1 800T-FXTPH16RA1 800H-FRXTPH16RA1
240V AC 800T-FXPH26RA1 800T-FXTPH26RA1 800H-FRXTPH26RA1
  
Note:X = Closed/O = Open
Note:Emergency stop push buttons are compliant with EN 418 and EN/IEC 60947-5-5 Standards when using N.C.L.B. contact blocks.
    
⋆ Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs.
‡ The Self Monitoring Contact Block (S.M.C.B.) is composed of a N.C.L.B. contact wired in series with a N.O. monitoring contact. The N.O. monitoring contact automatically closes when the S.M.C.B. is properly installed onto the E-stop operator. If the S.M.C.B. is separated from the E-stop operator, the N.O. monitoring contact will automatically open.
§ Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability of illuminated E-stops with Self Monitoring Contact Blocks (S.M.C.B.s).

Accessories

   Type Style Color Cat. No.
Click to enlarge - 800T_800H-1_42-3 Emergency Stop Legend Plates For 800T Buttons Yellow, Blank 800T-X646
Yellow, Emergency Stop 800T-X646EM
Click to enlarge - 800T_800H-1_44-8 For 800H Buttons Yellow, Emergency Stop 800H-W690