Lifeline 4
|
Description
The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access.
The Lifeline 4 is the only device of its kind to incorporate the following features in one unit making it the most versatile cable switch on the market.
| 1. | The positive mode mechanism helps ensure that the contacts are immediately latched open on actuation and can only be reset by the intentional action of turning the blue reset knob. The design also protects against nuisance tripping and the effects of thermal expansion. |
| 2. | A mushroom head emergency stop button is included on the unit to provide E-Stop access even at the extreme ends of the span. |
| 3. | The cable status indicator makes the system easy to set up and maintain for spans up to 125 meters. |
| 4. | Four sets of contacts are provided: 2 N.C. + 2 N.O. or 3 N.O. + 1 N.O. contacts. |
| 5. | Sealed to IP66 with rugged construction using die-cast alloy and stainless steel to withstand harsh conditions. |
Features
- Switches up to 125 meter span
- Universal mounting and operation
- Lid mounted emergency stop button, designed to conform to ISO 850
- Switch lockout on cable pulled and cable slack
- Cable status indicator on switch lid
Specifications
| Safety Ratings | |||||
| Standards | ISO 13850, EN ISO 12100, IEC 60947-5-1, IEC 60947-5-5 | ||||
| Safety Classification | Cat. 1 device per EN 954-1 May be suitable for use in Cat 3 or Cat 4 systems depending on the architecture and application characteristics |
||||
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d: > 2 x 106 operations at min. load PFHD: < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
||||
| Certifications | CE Marked for all applicable directives, cULus, TÜV, and CCC | ||||
| Outputs | |||||
| Safety Contacts T | 2 N.C. direct-opening action | 3 N.C. direct-opening action | |||
| Auxiliary Contacts | 2 N.O. direct-opening action | 1 N.O. direct-opening action | |||
| Thermal CurrentIlth | 10 A | ||||
| Rated Insulation Voltage | (Ui) 500V | ||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | ||||
| Utilization Category | |||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V |
| (le) | 1.2 A | 1.4 A | 3 A | 6 A | |
| DC-13 | (Ue) | 24V | |||
| (le) | 2 A | ||||
| Operating Characteristics | |||||
| Cable Span Between Switches, Max. | 75 m (246 ft) standard model and 75…125 m (146…410 ft) extended length model | ||||
| Tensioning Force to Run Position | 103 N (23.16 lbf) typical | ||||
| Tensioning Force to Lockout | 188 N (42.3 lbf) typical | ||||
| Operating Force, Min. | <125 N (28.1 lbf) at 300 mm deflection | ||||
| Actuation Frequency, Max. | 1 cycle/s | ||||
| Operating Life @ 100 mA load | 1 x 106 | ||||
| Environmental | |||||
| Enclosure Type Rating | IP66 | ||||
| Operating Temperature [C (F)] | -25…80° (-13…176°) | ||||
| Physical Characteristics | |||||
| Housing Material | Heavy-duty painted zinc-based die-cast alloy (LM24) | ||||
| Indicator Material | Glass-filled nylon | ||||
| Eye Nut Material | Stainless steel | ||||
| Weight [g (lb)] | 630 (1.38) | ||||
| Color | Yellow body, blue reset button | ||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
|||||
Note: It is recommended that the LRTS (Lifeline Rope Tensioning System) should be used with the Lifeline 4 cable rope switch.
Product Selection
| Cable Span | Safety Contacts | Auxiliary Contacts | Cat. No. | ||||
| Conduits | Connectors¬ | ||||||
| M20 | 1/2 inch NPT | 12-Pin M23 | 8-Pin MicroT | Connect to ArmorBlock Guard I/O 5-Pin Micro (M12) |
|||
| 75 m (246 ft) | 2 N.C. | 2 N.O. | 440E-L13137 | 440E-L13133 | 440E-L13140 | 440E-L21BNYH | 440E-L2NNNYS |
| 3 N.C. | 1 N.O. | 440E-L13042 | 440E-L13043 | 440E-L13141 | — | — | |
| 75…125 m (146…410 ft) | 2 N.C. | 2 N.O. | 440E-L13153 | 440E-L13155 | 440E-L13163 | 440E-L21BTYH | — |
| 3 N.C. | 1 N.O. | 440E-L13150 | 440E-L13152 | 440E-L13164 | — | — | |
| ¬ For connector ratings, see page Safety Switches and Connectors. T For connection to ArmorBlock Guard I/O. With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring for wiring details. With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring for wiring details. |
|||||||
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays for 2 N.C. Contact Switch | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 5-Pin Micro (M12) | 8-Pin Micro (M12) | 12-Pin M23 |
| Cordset | — | 889D-F8AB-§ | 889M-F12X9AE-§ |
| Patchcord | 889D-F5ACDM-¬ | 889D-F8ABDM-§ | 889M-F12AHMU-Ø |
¬ Replace symbol with 0M3 (0.3 m), 1 ( 1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard lengths.
§ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
§ Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Ø Replace symbol with 0M3 (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard length.
Accessories
Accessories (continued)
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
Standard Model
|
Extended Length Models (75…125 m cable span)
|
Note: 2D, 3D and electrical drawings are available on www.ab.com.
Typical Wiring Diagrams