Catalogs > Safety Products Catalog > Operator Interface > Emergency Stop Devices > Cable (Rope) Pull Switches > Lifeline 4
Lifeline 4
| Introduction | Specifications | Product Selection | Accessories | Approximate Dimensions | Typical Wiring Diagrams |
| Cable Span | Safety Contacts | Auxiliary Contacts | Cat. No. | ||||
| Conduits | Connectors¬ | ||||||
| M20 | 1/2 inch NPT | 12-Pin M23 | 8-Pin MicroT | Connect to ArmorBlock Guard I/O 5-Pin Micro (M12) |
|||
| 75 m (246 ft) | 2 N.C. | 2 N.O. | 440E-L13137 | 440E-L13133 | 440E-L13140 | 440E-L21BNYH | 440E-L2NNNYS |
| 3 N.C. | 1 N.O. | 440E-L13042 | 440E-L13043 | 440E-L13141 | — | — | |
| 75…125 m (146…410 ft) | 2 N.C. | 2 N.O. | 440E-L13153 | 440E-L13155 | 440E-L13163 | 440E-L21BTYH | — |
| 3 N.C. | 1 N.O. | 440E-L13150 | 440E-L13152 | 440E-L13164 | — | — | |
| ¬ For connector ratings, see page Safety Switches and Connectors. T For connection to ArmorBlock Guard I/O. With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring for wiring details. With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring for wiring details. |
|||||||
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays for 2 N.C. Contact Switch | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 5-Pin Micro (M12) | 8-Pin Micro (M12) | 12-Pin M23 |
| Cordset | — | 889D-F8AB-§ | 889M-F12X9AE-§ |
| Patchcord | 889D-F5ACDM-¬ | 889D-F8ABDM-§ | 889M-F12AHMU-Ø |
¬ Replace symbol with 0M3 (0.3 m), 1 ( 1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard lengths.
§ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
§ Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Ø Replace symbol with 0M3 (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard length.