Safety Relays

Catalogs > Safety Products Catalog > Logic > Safety Relays > Selection Navigator

Selection Navigator

Safety Relay Selection Navigator

Relay Model Cat. per
EN
954-1
Click to enlarge - e_stop_GS Click to enlarge - e-stop NCNO Click to enlarge - 2_hand Click to enlarge - 2_mat Click to enlarge - 2_curtin SE Immediate Outputs Delayed Outputs
Safety Auxiliary Safety Auxiliary
1 NC 2 NC 1 NC & 1 NO THC SM LC/
SG
EM NO SS NO EM NC SS NC SS NO EM NO EM NC SS NO EM NC SS NC SS NO
Single Function Safety Relays
MSR9T 3 1 2 1
MSR30RT/RTP 4 1 1 1 2 1
MSR33RT/RTP 4 1 2 1
MSR117 4 1 3 1
MSR126R/T 4 1 1 1 2
MSR127RP/TP 4 1 1 1 3 1
MSR131RP/TP 4 1 1 1 1 3 2 2
MSR142RTP 4 1 1 1 1 7 4 2
MSR144RTP 4 1 1 1 1 2 2 2  
Delayed Outputs
CU4 3 2 1
MSR38D/DP 4 1 1 1 1 2
MSR138DP 4/3 1 1 1 2 3
MSR138.1DP 4/3 1 1 1 2 2 1
MSR178DP 4 1 1 1 1 3 2
Specialty Safety Relays
Two-Hand Control
MSR35H/HP 4 2 1 2 1
MSR125H/HP 4 2 1 2
Muting LIght Curtain
MSR22LM 4 3 2 1 2
Stop Motion Monitors
CU2 1 1 2 1
Speed Monitors
MSR57P 4 1 1 1 1 1
Back EMF Monitors
CU3 1 2 1
Mat Controllers
MSR23 4 1 2 1
440F-C4000P 1 2 1
440F-C4000S 1 2 1
Mat Manager
C280** 3 8¬  6T  1
Safedge™ Controllers
251D 1‡  1
252D 1‡  1
C251P 1‡  1
Sipha Controllers
Sipha 1 3 1 1 1
Sipha 2 3 6 2 1
Sipha 6 4 6 2 1 1
  
Note: THC= Two-hand Control, SM = Safety Mat, LC = Light Curtain, SG = SensaGuard, SE = Safedge, EM = Electromechanical, SS = Solid State,
and • = included
¬  Up to 8 mats can be monitored.
T  Up to 6 mats can be monitored.
‡  Can support more than one edge in series or parallel.

Operating Voltage ResetT  Output Switching
Current, A
Housing
Width (mm)
Removable
Terminals
Additional
Information
Relay Model
24
DC
24
AC
115
AC
230
AC
Auto./
Man.
Mon.
Man.
250V
AC
24V
DC
  
4 3 45.5 Description MSR9T
2 22.5 Description MSR30RT/RTP
2 22.5 Description MSR33RT/RTP
5 3 22.5 Description MSR117
6 3 22.5 Description MSR126R/T
5 3 22.5 Description MSR127RP/TP
6 3 45.0 Description MSR131RP/TP
6 3 67.5 Description MSR142RTP
5 3 45.0 Description MSR144RTP
  
5 3 22.5 Description CU4
2 22.5 Description MSR38D/DP
6 3 45.0 Description MSR138DP
6 3 45.0 Description MSR138.1DP
4 2 35.0 Description MSR178DP
  
  
2 22.5 Description MSR35H/HP
6 3 22.5 Description MSR125H/HP
  
3 3 45.0 Description MSR22LM
  
4 3 45 Description CU2
  
67.5 Description MSR57P
  
4 3 45 Description CU3
  
3 3 22.5 & 45.0 Description MSR23M
4 2 210 Description 440F-C4000P
4 2 210 Description 440F-C4000S
  
4 2 210 Description C280
  
2 1 45 Description 251D
2 1 22.5 Description 252D
2 1 130 Description C251P
  
4 2 22.5 Description Sipha 1
4 2 45 Description Sipha 2
4 2 90 Description Sipha 6
  
Note: Auto./Man. = Automatic/Manual and Mon. Man. = Monitored Manual, and • = included

Relay Model Cat. per
EN 954-1
Click to enlarge - e_stop_GS Click to enlarge - e-stop NCNO Click to enlarge - 2_hand Click to enlarge - 2_mat Click to enlarge - 2_curtin SE Immediate Outputs Delayed Outputs
Safety Auxiliary Safety Auxiliary
1 NC 2 NC 1 NC & 1 NO THC SM LC/
SG
EM NO SS NO EM NC SS NC SS NO EM NO EM NC SS NO EM NC SS NC SS NO
Expansion Relays
MSR132E/EP 4 1 1 4 2
Delayed Outputs
MSR132ED/EDP 3 1 1 4 2
Modular Safety Relays (Series 200)
MSR210P 4 2 2 2 2 2 1 2
MSR211P 4 2 2 2 2 1 2
MSR220P 4 2 2 2 2
MSR221P 4 2 2 2
MSR230P 4 4
MSR238P 3 2 1
MSR240P
MSR241P  
MSR245P
Configurable Safety Relays (Series 300)
MSR310P 4 3
MSR312P 4 4
MSR320P 4 2 2 2 1 2 2 2
MSR329P
4











4






MSR330P 4 3 1
MSR338DP 3 3 1
Accessories
                     
                     
  
Note: THC= Two-hand Control, SM = Safety Mat, LC = Light Curtain, SG = SensaGuard, SE = Safedge, EM = Electromechanical, and SS = Solid State

Operating Voltage ResetT  Output Switching Current, A Housing Width (mm) Removable Terminals Additional Information Relay Model
24 DC 24 AC 115 AC 230 AC Auto./Man. Mon. Man. 250V AC 24V DC
  
6 3 22.5 Description MSR132E/EP
  
6 3 22.5 Description MSR132ED/EDP
  
3 2.5 45.0 Description MSR210P
3 2.5 45.0 Description MSR211P
17.5 Description MSR220P
17.5 Description MSR221P
3 2.5 22.5 Description MSR230P
5 3 22.5 Description MSR238P
17.5 Description MSR240P
45 Description MSR241P
144 Description MSR245P
  
35 Description MSR310P
35 Description MSR312P
17.5 Description MSR320P







30…200 mA 17.5

Description
MSR329P
6 3 22.5 Description MSR330P
5 3 22.5 Description MSR338DP
  
                       
                       
  
Note: Auto./Man. = Automatic/Manual and Mon. Man. = Monitored Manual, and • = included