MSR6R/T

Click to enlarge - 440R-C23017-9_Product


Description

The MSR6R/T has an internal switch that allows the user to select either 1 N.C. single channel input for use with gate interlock and emergency stop buttons in lower risk applications or 2 N.C. dual channel inputs for higher risk applications.

The MSR6R/T has an internal selector switch that can accommodate automatic/manual or a monitored manual reset function. Automatic/ manual reset can use a jumper or can be used to check operation of the contacts. Monitored manual requires the use of a manually operated normally open momentary switch to activate the outputs.

The MSR6R/T has 3 N.O. safety outputs and 1 N.C. auxiliary output. The safety outputs have independent and redundant internal contacts to help ensure the safety function. The auxiliary contact is a nonsafety output intended to provide an external signal about the status of the safety outputs.


Features


Applications

Click to enlarge - 440R-C23017-9_Application01

Specifications

Standards EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1
Category Cat. 3 per EN 954-1 (ISO 13849-1)
Certifications CE Marked for all applicable directives, cULus, c-Tick, and TÜV
Power Supply 24V AC/DC, 110V AC 50/60 Hz or 230V AC 50/60 Hz
Power Consumption <4 VA
Safety Inputs 2 N.C.
Input Simultaneity 0.5 seconds
Input Resistance, Max. 500 W
Reset Type Monitored Man. or Auto./Man.
Safety Outputs 3 N.O. Safety; 1 N.C. Auxiliary
Output Utilization per IEC60947-5-1 (Inductive)⋆  B300 AC-15; 4 A/250V AC, 4 A/120V AC
P300 DC-13; 3 A/24V DC
Thermal Current 4 A (nonswitching)
Fuses, Input 500 mA time lag (internal, replacable)
Fuses, Output 5 A quick acting (external)
Switching Current @ Voltage, Min. 10 mA/10V
Maximum Drop-Out Time 50 ms
Status Indicators Red = Power On; Green = K1 Closed; Green = K2 Closed; Amber = Single Channel Mode
Rated Impulse withstand Voltage 2500V
Installation Group C in accordance with VDE 0110
Pollution Degree 3
Operating Temperature [C (F)] -10…55° (14…131°)
Relative Humidity 90%
Enclosure Type Rating IP40, (NEMA 1), DIN 0470
Terminal Protection IP20, DIN 0470
Conductor Size, Max. 1 x 2.5 mm2 (14 AWG) stranded, 1 x 4 mm2 (12 AWG) solid
Torque Settings—terminal screws 1 N•m (8.85 lb•in)
Material Red Polycarbonate
Mounting 35 mm DIN Rail
Weight [g (lb)] 510 (1.12)
Electrical Life 220V AC/4A/880VA cosf = 0.35 - 100,000 operations
220V AC/1.7A/375VA cosf = 0.6 - 500,000 operations
30V DC/2A/60W - 1,000,000 operations
10V DC/0.01A/0.1W - 2,000,000 operations
Mechanical Life 2,000,000 operations
Vibration 0.75 mm (0.30 in.) peak, 10…55 Hz
Shock 30 g, 11 ms half-sine
  
⋆ See Output Ratings on Output Ratings for details. Consult factory for ratings not shown.

Applications

Click to enlarge - 440R-C23017-9_Application02

Product Selection

Inputs Safety Outputs Auxiliary Outputs Power Supply Cat. No.
1 N.C. or 2 N.C. 3 N.O. 1 N.C. 24V AC/DC 440R-C23017
110V AC 440R-C23018
230V AC 440R-C23019
  

Accessories

Description Page Number Cat. No.
500 mA fuse—Bussmann Cat. No. ETF-500 mA Accessories 440R-A31562
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-C2301#_Dim

Block Diagram

Click to enlarge - 440R-C2301#_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-C2301#_Wiring 01      Click to enlarge - 440R-C2301#_Wiring 02
   
Single-Channel Safety Gate, Monitored Manual Reset, Single-Channel Output , Monitored Output Single-Channel Safety Gate, Automatic Reset, Single-Channel Output, No Monitored Output

Click to enlarge - 440R-C2301#_Wiring 03   Click to enlarge - 440R-C2301#_Wiring 04
     
Dual-Channel Safety Gate, Monitored Manual Reset, Dual-Channel Output , Monitored Output   Dual-Channel Safety Gate, Automatic Reset, Dual-Channel Output, Monitored Output