MSR33RT/RTP

Click to enlarge - 440R-F23199-200_Product


Description

The Minotaur MSR33RT/RTP is a microprocessor-based, monitoring safety relay, with safety-rated, solid-state outputs.

The MSR33RT/RTP is designed to operate with dual channel inputs where one channel is normally closed and the other is normally open. The Sipha sensors can be connected to the MSR33RT/RTP inputs.

Test pulses are used to dynamically check the input circuits. All inputs and outputs are short-circuit protected.

The reset capability of the MSR33RT/RTP allows it to set up for monitored manual or automatic reset. A start-up test can be enabled if automatic reset is used. The start-up test requires the inputs to be cycled before energizing the outputs. The reset and start-up test is determined by the connection wiring.

The outputs include two normally-open safety-rated outputs that can be connected to loads up to 2 A at 24V DC. These outputs can be used to send a safety stop signal to a machine or manufacturing system.

The MSR33 also has one solid-state, normally-open auxiliary output, which must only be used to indicate status of the MSR33RT/RTP.


Features


LED Indicators

Green Power (Pwr)
Green CH1 Energized
Green CH2 Energized
  

Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, ANSI B11.19, AS 4024.5
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 9.2 x 10-10
MTTFd: > 631 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL CL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and TÜV
Power Supply
Input Power Entry 24V DC SELV
Power Consumption 3 W
Inputs
Safety Inputs 1 N.C. + 1 N.O.
Input Simultaneity Infinite
Input Resistance, Max. 200 W
Reset Auto. or Monitored Manual
Power On Delay/
Recovery Time
3 seconds/20 ms
Response Time 15 ms
Outputs
Safety Contacts 2 N.O. Solid State
Auxiliary Contacts 1 N.O. Solid State
Power LED Diagnostics 3 s Blink: Initialization
Constant: Normal Operation
2 Blinks: Configuration change during operation
4 Blinks: Solid state output switch fault
Continuous blinking: Internal fault
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1), DIN VDE 0470-1/
IP20
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting In panel enclosure (IP54); 35 mm DIN Rail
Weight [g (lb)] 130 (0.287)
Conductor Size, Max. 0.2…2.5 mm2 (24…14 AWG)
 
⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years

Wiring Terminations

S11 & S21 Pulse checking dynamic output
S12 & S22 Input contacts
A1 – S34 Reset switch
S11 – S34 Automatic reset, start-up test disabled
S21 – S34 Automatic reset, start-up test enabled
A1 – Y2 Monitoring circuit
 

Product Selection

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
1 N.C. & 1 N.O. 2 N.O. Solid State 1 N.O. Solid State Fixed Auto. or Monitored Manual 24V DC SELV 440R-F23199
Removable 440R-F23200
  

Accessories

Description Cat. No.
Bag of 4, 4-Pin Screw Terminal Blocks 440R-A23209
Bag of 4, 4-Pin Spring Clamp Terminal Blocks 440R-A23228
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-F23#_Dim

Block Diagram

Click to enlarge - 440R-F23#_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-F23#_Wiring 01   Click to enlarge - 440R-F23#_Wiring 02
 
Sipha Sensor Inputs, Dual Channel Outputs,
Monitored Manual Reset, Output Monitoring Start-up Test Disabled
  Sipha Sensor Inputs, Dual Channel Outputs,
Automatic Reset, No Output Monitoring Start-up Test Enabled
 
Click to enlarge - 440R-F23#_Wiring 03   Click to enlarge - 440R-F23#_Wiring 04
 
Dual Channel Inputs, Dual Channel Outputs,
Monitored Manual Reset, Output Monitoring Start-up Test Disabled
  Dual Independent Inputs, Dual Channel Outputs,
Automatic Reset, No Output Monitoring Start-up Test Disabled