MSR124RT
|
Description
The Allen-Bradley Guardmaster Minotaur MSR124RT is a safety monitoring relay that provides versatile inputs and monitoring capability with a large number of safety outputs in a 100mm package.
The MSR124RT can be connected as either a single or dual channel safety gate or e-stop, or can be connected to a light curtain that provides cross fault detection.
Reset and output monitoring are determined by the wiring configuration. Automatic/manual reset can use a jumper or can be used to check operation of the contacts. Monitored manual requires the use of a manually operated normally open momentary switch to activate the outputs.
The outputs include 5 normally open safety rated outputs and 1 auxiliary output. The safety outputs have independent and redundant internal contacts to help ensure the safety function. The auxiliary output is not safety rated and shall only be used for indication purposes.
Features
- Category 4 per EN 954-1
- Stop category 0
- 5 Safety contacts N.O.
- Single/dual channel operation
- Cross fault monitoring
- Monitored or automatic reset
- E-stop, safety gate or light curtain applications
LED Indicators
| Green | Power On |
| Green | Output On |
Contact Current Limit Curve
|
Specifications
| Safety Ratings | ||
| Standards | EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 | |
| Safety Classification | Cat. 4 per EN 954-1 (ISO 13849-1) | |
| Functional Safety Data ⋆ Note: For up-to-date information, visit http://www.ab.com/safety/ |
PFHD: < 2.5 x 10-9 MTTFd: > 45662 years Suitable for performace levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
|
| Certifications | CE Marked for all applicable directives, cULus, C-Tick, and BG | |
| Power Supply | ||
| Input Power Entry | — | |
| Power Consumption | 3 W | |
| Inputs | ||
| Safety Inputs | 1 N.C., 2 N.C., or LC | |
| Input Simultaneity | Infinite | |
| Input Resistance, Max. | 50 W | |
| Reset | — | |
| Power On Delay/Recovery Time | 1 second/1 second | |
| Response Time | 20 ms | |
| Outputs | ||
| Safety Contacts | — | |
| Auxiliary Contacts | — | |
| Thermal CurrentIlth | Nonswitching—See limit curve, max 10 A in one current path | |
| Rated Impulse withstand VoltageIlth | 2500V | |
| Switching Current @ Voltage, Min. | 10 mA/10V | |
| Fuses, Output (External) | External 6 A slow-blow or 10 A fast acting | |
| Electrical Life (Operations) | 220V AC/4A/880VA cosf = 0.35 - 100,000 operations 220V AC/1.7A/375VA cosf = 0.6 - 500,000 operations 30V DC/2A/60W - 1,000,000 operations 10V DC/0.01A/0.1W - 2,000,000 operations |
|
| Mechanical Life | 2,000,000 operations | |
| Utilization Category | ||
| Resistive: AC-1 | 10 A/250V AC | |
| Resistive: DC-1 | 10 A/24V DC | |
| Inductive: AC-15 | 4 A/250V AC | 4 A/125V AC |
| Inductive: DC-13 | 2 A/24V DC | 10 A/24V DC @ 6 ops/min |
| Environmental | ||
| Enclosure Type Rating/ Terminal Protection |
IP40 (NEMA 1)/ IP 20 |
|
| Operating Temperature [C (F)] | -5…55° (23…131°) | |
| Vibration | 10…55 Hz, 0.35 mm | |
| Shock | 10 g, 16 ms, 100 shocks | |
| Physical Characteristics | ||
| Mounting | 35 mm DIN Rail | |
| Weight [g (lb)] | 24V DC: 550 (1.21) 110 and 230V AC: 710 (1.57) |
|
| Conductor Size, Max. | — | |
| ⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions: - Mission time/Proof test interval of 20 years - Power cycled once per 8 hrs |
||
Product Selection
| Inputs | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. No. |
| 1 N.C., 2 N.C., Light Curtain | 5 N.O. | 1 N.C. | Fixed | Auto/Manual or Monitored Manual | 24/115/230V AC 0.8 x 1.1 x rated voltage, 50/60 Hz (0.85 - 1.1 x 24V DC) | 440R-G23110 |
| 115V AC 24V DC |
440R-G23108 | |||||
| 230V AC/24V DC | 440R-G23107 | |||||
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|
Block Diagram
|
AC Supply via A1…A2,
24V DC Supply via A3…A4
|
| AC Supply via A1…A2, 24V DC Supply via A3…A4 |
Typical Wiring Diagrams