MSR127RP/TP

Click to enlarge - 440R-N23124-35_Product


Description

The MSR127RTP can be connected in three different input wiring configurations: one normally closed, two normally closed, or with two PNP connections from a light curtain. When connected in the two normally closed fashion, the MSR127RTP checks for cross faults across the two inputs. When connected to light curtains, the light curtain must perform the cross fault detection.

The MSR127RP has a monitored manual reset. The MSR127TP has an automatic/manual reset. Models with automatic/manual reset can have the reset jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop. Models with monitored manual reset provide checking of the output monitoring circuit.

The outputs include three normally open safety-rated outputs as well as one normally closed auxiliary output. The safety outputs have independent and redundant internal contacts to support the safety function. The auxiliary output is a nonsafety output intended to provide an external signal about the status of the safety outputs.


Features


LED Indicators

Green Power On
Green CH1 Closed
Green CH2 Closed
  

Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 1.45 x 10-9
MTTFd: > 398 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus and BG
Power Supply
Input Power Entry 24V AC/DC, 115V AC or 230V AC 50/60 Hz
Power Consumption 2 W
Inputs
Safety Inputs 1 N.C. or 2 N.C. or LC
Input Simultaneity Infinite (ch2 before ch1) with Auto Reset
Input Resistance, Max. 110 W
Reset Auto./Manual or Monitored Manual
Power On Delay/
Recovery Time
1 second/100 ms
Response Time 15 ms
Outputs
Safety Contacts 3 N.O.
Auxiliary Contacts 1 N.C.
Thermal CurrentIlth Units with 24V AC/DC supply: 3 x 4 A or 2 x 5 A nonswitching
Units with 115/230V AC supplies: 3 x 3 A or 2 x 4 A or 1 x 5 A nonswitching
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA/10V
Fuses, Output External 6 A slow blow or 10 A fast acting
Electrical Life (Operations) (With surge suppression)
250V AC/6 A/1500VA cosf = 1…0.1 M
250V AC/2.5 A/625VA cosf = 1…0.5 M
250V AC/1.5 A/375VA cosf = 0.35…0.3 M
250V AC/5 A/1250VA cosf = 0.6…0.1 M
24V DC/2 A/48 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 operations
Utilization Category UL: B300, R300 5 A/250V AC, 24V DC
Resistive: AC-1 5 A/250V AC  
Resistive: DC-1 5 A/24V DC  
Inductive: AC-15 5 A/250V AC  
Inductive: DC-13 3 A/24V DC 5 A/24V DC @ 6 ops/min
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1)/
IP20
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 24V DC: 210 (0.46), 115/230V AC: 260 (0.57)
Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
1 N.C., 2 N.C., Light Curtain 3 N.O. 1 N.C. Fixed Auto./Manual 24V AC/DC 440R-N23126
Monitored Manual 440R-N23129
Auto./Manual 115V AC 440R-N23125
Monitored Manual 440R-N23128
Auto./Manual 230V AC 440R-N23124
Monitored Manual 440R-N23127
Removable (Screw) Auto./Manual 24V AC/DC 440R-N23132
Monitored Manual 440R-N23135
Removable (Spring Clamp) Auto./Manual 24V AC/DC 440R-N23132S
Monitored Manual 440R-N23135S
Removable (Screw) Auto./Manual 115V AC 440R-N23131
Monitored Manual 440R-N23134
Auto./Manual 230V AC 440R-N23130
Monitored Manual 440R-N23133
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-N23124-35_Dim

Block Diagram

Click to enlarge - 440R-N23124-35_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-N23124-35_Wiring 01      Click to enlarge - 440R-N23124-35_Wiring 02
 
Light Curtain, Monitored Manual Reset, Monitored Output      Single Channel E-Stop, Automatic Reset, No Output Monitoring
 
Click to enlarge - 440R-N23124-35_Wiring 03      Click to enlarge - 440R-N23124-35_Wiring 04
 
Dual Channel E-Stop, Monitored Manual Reset, Monitored Output      Dual Channel Safety Gates, Automatic Reset, Monitored Output