Catalogs > Safety Products Catalog > Logic > Safety Relays > Single-Function Safety Relays > MSR127RP/TP
MSR127RP/TP
| Introduction | Specifications | Product Selection | Approximate Dimensions—mm (inches) | Block Diagram | Typical Wiring Diagrams |
| Safety Ratings | ||
| Standards | EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 | |
| Safety Classification | Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1 | |
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
PFHD: < 1.45 x 10-9 MTTFd: > 398 years Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
|
| Certifications | CE marked for all applicable directives, cULus, and TÜV | |
| Power Supply | ||
| Input Power Entry | 24V AC/DC, 115V AC or 230V AC 50/60 Hz | |
| Power Consumption | 2 W | |
| Inputs | ||
| Safety Inputs | 1 N.C. or 2 N.C. or LC | |
| Input Simultaneity | Infinite (ch2 before ch1) with Auto Reset | |
| Input Resistance, Max. | 110 W | |
| Reset | Auto./Manual or Monitored Manual | |
| Power On Delay/ Recovery Time |
1 second/100 ms | |
| Response Time | 15 ms | |
| Outputs | ||
| Safety Contacts | 3 N.O. | |
| Auxiliary Contacts | 1 N.C. | |
| Thermal CurrentIlth | Units with 24V AC/DC supply: 3 x 4 A or 2 x 5 A nonswitching Units with 115/230V AC supplies: 3 x 3 A or 2 x 4 A or 1 x 5 A nonswitching |
|
| Rated Impulse withstand Voltage | 2500V | |
| Switching Current @ Voltage, Min. | 10 mA/10V | |
| Fuses, Output | External 6 A slow blow or 10 A fast acting | |
| Electrical Life (Operations) | (With surge suppression) 250V AC/6 A/1500VA cosf = 1…0.1 M 250V AC/2.5 A/625VA cosf = 1…0.5 M 250V AC/1.5 A/375VA cosf = 0.35…0.3 M 250V AC/5 A/1250VA cosf = 0.6…0.1 M 24V DC/2 A/48 W = 1 M 10V DC/0.01 A/0.1 W = 2 M |
|
| Mechanical Life | 2,000,000 operations | |
| Utilization Category | UL: B300, R300 5 A/250V AC, 24V DC | |
| Resistive: AC-1 | 5 A/250V AC | |
| Resistive: DC-1 | 5 A/24V DC | |
| Inductive: AC-15 | 5 A/250V AC | |
| Inductive: DC-13 | 3 A/24V DC | 5 A/24V DC @ 6 ops/min |
| Environmental and Physical Characteristics | ||
| Enclosure Type Rating/ Terminal Protection |
IP40 (NEMA 1)/ IP20 |
|
| Operating Temperature [C (F)] | -5…55° (23…131°) | |
| Vibration | 10…55 Hz, 0.35 mm | |
| Shock | 10 g, 16 ms 100 shocks | |
| Mounting | 35 mm DIN Rail | |
| Weight [g (lbs)] | 24V DC: 210 (0.46), 115/230V AC: 260 (0.57) | |
| Conductor Size, Max. | 0.2…4 mm2 (24…12 AWG) | |
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions: - Mission time/Proof test interval of 20 years - Functional test at least once within six-month period |
||