MSR142RTP

Click to enlarge - MSR142RTP_Product_4C


Description

The MSR142RTP is a versatile monitoring safety relay. It can be connected in four different input wiring configurations: one normally closed, two normally closed, two PNP connections from a light curtain, or a four-wire safety mat. When connected in the two normally closed fashion, the MSR142RTP checks for cross faults across the two inputs. When connected to light curtains, the light curtain must perform the cross-fault detection.

The MSR142RTP has output monitoring that can accommodate either automatic/manual reset or a monitored manual reset. When configured with automatic/manual reset (jumpers on X1-X2 and X3-X4), the MSR142RTP can have the reset terminals S33-S34 jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop (S33-S34). When configured to monitored manual reset, the MSR142RTP checks the output monitoring circuit through the manual application of the reset switch.

The outputs include seven normally open safety-rated outputs, four normally closed auxiliary outputs, and two solid-state outputs. One solid-state output indicates that the inputs are closed. The second solid-state output indicates that the safety outputs are active. The safety outputs have independent and redundant internal contacts to support the safety function. The auxiliary outputs are nonsafety outputs intended to provide an external signal about the status of the safety outputs.


Features


LED Indicators

Green Power
Green Start
Green CH1 IN
Green CH2 IN
Green CH1 output energized
Green CH2 output energized
  

Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, AS 4042.1, ISOTR 12100, B11.19
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 1.92 x 10-9
MTTFd: > 210 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, TÜV, and c-Tick
Power Supply
Input Power Entry 24V AC/DC, 115V AC or 230V AC 50/60 Hz
Power Consumption 5 W
Inputs
Safety Inputs 1 N.C., 2 N.C., Light Curtain or 4-Wire Safety Mat
Input Simultaneity Infinite
Input Resistance, Max. 45 ohms
Reset Auto./Manual or Monitored Manual
Power On Delay/
Recovery Time
1 s/100 ms
Response Time 15 ms
Outputs
Safety Contacts 7 N.O.
Auxiliary Contacts 4 N.C., 2 PNP
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA @ 10V DC
Fuses, Output 6 A slow blow or 10 A quick blow (external)
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A/375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 operations
Utilization Category
Inductive: Safety & Aux.: AC-15 6 A/250V AC
Inductive: AC-13 3 A/24V DC
Resistive: DC-13 20 mA/30V DC short-circuit protected
UL 4 x B300 or 7 x 4 A Resistive
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1), DIN VDE 0470-1/
IP20
Operating Temperature [C (F)] -5…+55 ° (14…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 24V: 470 (1.04); 115/230V AC: 607 (1.34)
Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)
 
⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
1 N.C., 2 N.C., Light Curtain, Safety Mat 7 N.O. 4 N.C., 2 PNP, solid state Removable Monitored Manual or Auto/Manual 24V AC/DC 440R-G23216
115V AC 440R-G23215
230V AC 440R-G23214
  

Accessories

Description Cat. No.
Bag of 4, 4-Pin Screw Terminal Blocks 440R-A23209
Bag of 4, 4-Pin Spring Clamp Terminal Blocks 440R-A23228
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-G232#_Dims

Block Diagram

Click to enlarge - 440R-G232#_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-G232#_Wiring 01      Click to enlarge - 440R-G232#_Wiring 02
 
LIght Curtain, Monitored Manual Reset,
Monitored Output
     Single Channel Safety Gate, Auto Reset,
No Output Monitoring
 
Click to enlarge - 440R-G232#_Wiring 03      Click to enlarge - 440R-G232#_Wiring 04
 
Dual Channel E-Stop, Monitored Manual Reset, Monitored Output      Safety Mat, Automatic Reset, No Output Monitoring