MSR144RTP

Click to enlarge - MSR144RTP_Product_4C


Description

The MSR144RTP is a versatile monitoring safety relay. It can be connected in four different input wiring configurations: one normally closed, two normally closed, two PNP connections from a light curtain, or a four-wire safety mat. When connected in the two normally closed fashion, the MSR144RTP checks for cross faults across the two inputs. When connected to light curtains, the light curtain must perform the cross-fault detection.

Any combination of up to five MSR230 and MSR238 output modules can be easily connected to the MSR144RTP by removing the terminator, inserting a ribbon cable from the expander and then placing the terminator into the last expansion module.

The MSR144RTP has output monitoring that can accommodate either automatic/manual reset or a monitored manual reset. When configured with automatic/manual reset (jumpers on X1-X2 and X3-X4), the MSR144RTP can have the reset terminals S33-S34 jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop (S33-S34). When configured to monitored manual reset, the MSR144RTP checks the output monitoring circuit through the manual application of the reset switch.

The outputs include two normally open safety rated outputs, two normally closed auxiliary outputs, and two solid-state auxiliary outputs. One solid-state output indicates the inputs are closed. The second solid-state output indicates the safety outputs are active.

The safety outputs have independent and redundant internal contacts to help ensure the safety function. The auxiliary outputs are nonsafety outputs intended to provide an external signal about the status of the safety outputs.


Features


LED Indicators

Green Power
Green Start
Green CH1 IN
Green CH2 IN
Green CH1 output energized
Green CH2 output energized
  

Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, AS 4024.1, ISOTR 12100
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 1.67 x 10-9
MTTFd: > 389 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, TÜV, and c-Tick
Power Supply
Input Power Entry 24V DC
Power Consumption 4 W + expanders
Inputs
Safety Inputs 1 N.C., 2 N.C., LC or 4-wire safety mat
Input Simultaneity Infinite
Input Resistance, Max. 45 ohms
Reset Auto./Manual or Monitored Manual
Power On Delay/
Recovery Time
1 s/100 ms
Response Time 15 ms
Outputs
Safety Contacts 2 N.O.
Auxiliary Contacts 2 N.C., 2 PNP
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA @ 10V DC
Fuses, Output 6 A slow blow or 10 A quick blow (external)
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A/375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 operations
Utilization Category
Inductive: Safety & Aux.: AC-15 5 A/250V AC
Inductive: Safety & Aux.: DC-13 3 A/24V DC
UL B300, R300, 1 x 6 A or 2 x 5 A resistive/250V AC, 24V DC
Solid State: 20 mA/30V DC short circuit protection
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1), DIN VDE 0470-1/
IP20
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 315 (0.71)
Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)
 
⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
1 N.C., 2 N.C., Light Curtain, Safety Mat 2 N.O. 2 N.C. 2 PNP solid state Removable Monitored Manual or Auto/Manual 24V DC 440R-C23205
  

Accessories

Description Cat. No.
Bag of 4, 4-Pin Screw Terminal Blocks 440R-A23209
Bag of 4, 4-Pin Spring Clamp Terminal Blocks 440R-A23228
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-C23205_Dims

Block Diagram

Click to enlarge - 440R-C23205_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-C23205_Wiring 01      Click to enlarge - 440R-C23205_Wiring 02
 
Light Curtain, Manual Reset with Manual Reset      115V/230V AC Supply, 24V DC, Dual Channel, Automatic Reset, Monitored Output
 
Click to enlarge - 440R-C23205_Wiring 03      Click to enlarge - 440R-C23205_Wiring 04
 
Dual Channel E-Stop, Monitored Manual Reset, Monitored Output      Safety Mat, Automatic Reset, No Output Monitoring