MSR178DP

Click to enlarge - 440R-M23227_MSR178_4C


Description

The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, off-delay or single-pulse modes. It is used for applications such as delayed unlocking of safety gates, delayed de-energizing of variable speed controlled motors, or jogging (single pulse) in teaching or setup mode.

The MSR178DP can be used e.g. in conjunction with a power to release or power to lock guard locking switch to time out high inertia machines with significant run down in potentially dangerous equipment. The single-pulse mode enables implementation of two-hand control by use of two normally open contacts. It also can be used as a preset time limited mute dependent bypass in order to clear a blockage in the muting sensor area.

The operating function is selected by external jumpers to Y21 and Y22. The delay time is selected by a combination of external jumpers to Y31 and Y32 and the potentiometer located on the front face.

The input to the MSR178DP can be connected in five different configurations: one normally closed, two normally closed, one normally open, two normally open, or two PNP connections from a light curtain. The normally closed connections are used for off-delay timing. The normally open inputs are used for on-delay timing and the single-pulse function. To generate the single pulse both inputs must be closed within 0.5 seconds. Thus a two-hand control arrangement in accordance with EN 574 Cat. IIIA can be used to trigger the single pulse.

The MSR178DP has three normally open redundant safety outputs. The two normally closed outputs can be connected in series to achieve redundant safety or connected in parallel for auxiliary signaling. External devices can be monitored by the Y11 terminal. Power to the MSR178DP can be either 24V AC/DC (24V/GND terminals) or 115V AC (A3/A2 terminals), or 230V AC (A1/A2 terminals).

The MSR178DP can be used as a standalone control module or in combination with an MSR safety relay to combine instant and delayed safety outputs, as needed.


Features


Specifications

Safety Ratings
Standards EN 954-1, IEC 61508, EN IEC 62061, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, EN 61812-1, AS 4024.1, ISOTR 12100, B11.19
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 2.74 x 10-9
MTTFd: > 285 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and TÜV
Power Supply
Input Power Entry 24V AC/DC, 115/230V AC 50/60 Hz
Power Consumption 4 W
Inputs
Safety Inputs 1 or 2 N.O., 1 or 2 N.C., Light Curtain
Input Simultaneity Infinite for On-/Off-delay, 0.5 s for single pulse function
Input Resistance, Max. 900 W
Reset Automatic
Power On Delay/
Recovery Time
500 ms/300 ms single pulse only
Response Time <±0.5% (at constant temp)
Outputs
Safety Contacts 3 N.O.
Auxiliary Contacts 2 N.C.
Thermal CurrentIlth 6 A
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA @ 10V DC
Fuses, Output External 6 A slow blow or 10 A quick blow
Electrical Life (Operations) 230V AC/4 A/880VA cosf = 0.35…0.1 M
230V AC/1.7 A375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 operations
Utilization Category
Inductive: AC-15 6 A/250V AC
Inductive: DC-13 3 A/24V DC
UL: B300, 6 A/250V AC, 3 A/24V DC
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1), DIN VDE 0470-1/
IP20
Operating Temperature [C (F)] -5…+55 ° (14…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 325 (0.72)
Conductor Size, Max. 0.2…4 mm2 (24… 12 AWG)
 
⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
1 or 2 N.O., 1 or 2 N.C., Light Curtain, Two-Hand Control, Enabling Switch 3 N.O. 2 N.C. Removable Automatic 24V AC/DC, 115V AC or 230V AC 440R-M23227
  

Accessories

Description Cat. No.
Bag of 4, 3-Pin Screw Terminal Blocks 440R-A23210
Bag of 4, 3-Pin Spring Clamp Terminal Blocks 440R-A23229
  

LED Indicators

PWR: Green Power on
Flashing Green/Red Faillure
CH1/2 IN: Static Green Input closed
Flashing Green Time lapse
CHT1: Green Output CH1 Active
CHT2: Green Output CH2 Active
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-M23227_Dims

Block Diagram

Click to enlarge - 440R-M23227_Block Diagram

Typical Wiring Diagrams

Click to enlarge - MSR178 Wiring


Click to enlarge - 440R-M23227_Wiring 01 MSR178DP generates
OFF-delayed solenoid
release after E-Stop
on MSR127
 
Click to enlarge - 440R-M23227_Wiring 02 MSR178DP ON-delayed
unlocking the Gate after
maintained stop switch
pressed

Jumper Configuration

Operating Function
Y10…Y21
Y10…Y22
B11…Y22
ON Delay
OFF Delay
Single Pulse
Time Range

Y10…Y31
Y10…Y32
Y10…Y31…Y32
0.5…10 s
1…30 s
5…300 s
1…30 min
Cross Fault Detection on Inputs

B11…B21
Enabled
Disabled
Feedback Loop
Y10…Y11 Close before reset
  

Time Function Diagrams

Click to enlarge - 440R-M23227_(TimeFunctions)_Diagram