Sipha™ Control Units
|
Description
With the increasing speed and complexity of applications a simple magnetic switch may be insufficient to meet the increased risks, therefore Siphas design incorporates several magnetically sensitive elements which must be triggered in a particular sequence to operate correctly. The Sipha sensor, designed to operate with its own actuator, helps prevent defeatability by a simple magnet.
The control unit is available in three types. The Sipha 1 control unit operates on 24V AC/DC and offers one normally open safety output and one normally closed solid-state auxiliary output. The Sipha 2 control unit operates on either 24V AC/DC, 110V AC or 230V AC and offers two normally open safety outputs and one normally closed auxiliary output. The Sipha 6 has wiring terminals for up to six sensors, a delayed output for Category 1 stops and offers the same wide range of power supply capability as the Sipha 2 control unit. Between two and six Sipha sensors can be directly connected to the Sipha 6 control unit. An internal DIP switch mutes the unused connections to sensors 1, 2, 3 and 4. This allows for individual monitoring to each interlock and provides enhanced safety integrity when compared to six interlocks running off a single Sipha 2 control unit.
The Sipha control units are designed to operate with the Sipha sensors and actuators. The controllers have automatic reset.
Features
- Noncontact actuation
- Magnetic coded sensing
- Control unit acts as safety relay
- Four types of switches
LED Indicators
| Green LED | Power on |
| Green LED | Output Closed |
Specifications
| Safety Ratings | |
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/EN60947-5-1, ANSI B11.19, AS4024.1 |
| Safety Classification | Sipha 1 & 2: Cat. 3 per EN954-1 Sipha 6: Cat. 4 per EN954-1 |
| Certifications | CE Marked for all applicable directives, cULus, and TÜV |
| Power Supply | |
| Input Power Entry | Sipha 1: 24V AC/DC; Sipha 2 & 6: 24V AC/DC and 115/230V AC |
| Power Consumption | Sipha 1: <2VA Sipha 2 & 6: <4VA |
| Inputs | |
| Safety Inputs | Sipha 1: 1 N.C. & 1 N.O. Sipha 2 & 6: 6 x (1 N.C. & 1 N.O.) |
| Input Resistance, Max. | Terminals 1…4: 200 W Terminals 2…3: 150 W |
| Outputs | |
| Safety Contacts | Sipha 1: 1 N.O. Sipha 2: 2 N.O. Sipha 6: 2 N.O. + 1 N.O. Delayed (0.6…30 sec.) |
| Auxiliary Contacts | 1 N.C. |
| Rated Impulse withstand Voltage | 2500V |
| Switching Current @ Voltage, Min. | 10 mA @ 10V |
| Fuses, Output | External 5 A quick blow AC, 3 A quick blow DC |
| Electrical Life (Operations) | 220V AC/4 A/880VA cosf = 0.35…0.1 M 220V AC/1.7 A375VA cosf = 0.6…0.5 M 30V DC/2 A/60 W = 1 M 10V DC/0.01 A/0.1 W = 2 M |
| Mechanical Life | 2,000,000 operations |
| Environmental and Physical Characteristics | |
| Operating Temperature [C (F)] | -10…+55° (+14…+131°) |
| Vibration | 1 mm, 10…55 Hz |
| Shock | 30 g, 11 ms half-sine |
| Mounting | 35 mm DIN Rail |
| Weight [g (lb)] | Sipha 1: 140 (0.31) Sipha 2: 410 (0.90) Sipha 6: 675 (1.49) |
| Conductor Size, Max. | 0.2…2.5 mm2 (24…14 AWG) |
| ⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions: - Mission time/Proof test interval of 20 years - Functional test at least once within six-month period |
|
Product Selection
Accessories
| Description | Cat. No. |
| Replacement Fuse, 500 mA | 440R-A31562 |
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
| Sipha Control Unit Type 1 | Sipha Control Unit Type 2 | Sipha 6 Control Unit | ||
|
|
|
Block Diagrams
| Sipha 1 | Sipha 2 |
|
|
Typical Wiring Diagrams