CU2

Click to enlarge - 440R-S07279-84_Product


Description

The CU2 control unit is a compact timing and stop motion detector interface module. By utilizing two independent inductive proximity inputs, which monitor the movement of two metal parts of the machine (e.g., sprockets, cams or linkages). The control unit detects when hazardous motion has ceased. When the hazardous motion has stopped the unit will send a signal to unlock guard locking devices. It has been developed to integrate guard locking interlock switches on machines which have variable or unpredictable run down cycles.

A removable cover allows access to the DIP switches and potentiometer which control the timing. The on-delay may be adjusted between 0.1 seconds to 40 minutes, through a series of 4 broad time ranges. The final adjustment is made by a potentiometer.

The Y1/Y2 terminals provide a check of contactors at machine power up. This is only relevant to certain special applications. For normal use these terminals should be linked. After all motion has ceased, the normally open safety on contacts close, which may be used to energize electrically operated solenoid locking guard switches. In addition the normally closed contacts open to indicate the unit’s status.

LED indication in the unit displays power, timer on, and outputs.


Features


LED Indicators

Red Power on
Red/Green Timing/Output On
  

Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 per EN 954-1 (ISO 13849-1), SIL CL1 per EN IEC 62061, PL c per ISO 13849-1
Certifications CE Marked for all applicable directives, cULus, c-Tick, and TÜV
Power Supply
Input Power Entry 24V AC/DC or 110/230V AC
Power Consumption <4 VA
Inputs
Safety Inputs 1 NPN and 1 PNP, Normally Open
Input Resistance, Max. 500 W
Reset Automatic/Manual
Outputs
Safety Contacts 2 N.O.
Auxiliary Contacts 1 N.C.
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA @ 10V
Fuses, Output 5 A quick acting (external)
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 operations
Utilization Category
Inductive: B300: AC-15 5 A @ 250V AC 5 A @ 120V AC
Inductive: DC-13 3 A/24V DC  
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1), DIN 0470/
IP20, DIN 0470
Operating Temperature [C (F)] -10…+55 ° (14…131 °)
Vibration 0.75 mm (0.30 in) peak, 10…55 Hz
Shock 30 g, 11 ms half-sine
Mounting 35 mm DIN Rail
Weight [g (lb)] 360 (0.79)
Conductor Size, Max. 1 x 2.5 mm2 (14 AWG) stranded, 1 x 4 mm2 (12 AWG) solid
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Description Sensor Voltage Sensor Size (mm) Sensing Distance (mm) Terminals Reset Type Control Unit Voltage Cat. No.
Controller and Sensors 24V DC supplied by Control Unit 12 3 Fixed Automatic/Manual 24V AC/DC 440R-S07279
110/230V AC 440R-S07280
18 5 24V AC/DC 440R-S07281
110/230V AC 440R-S07282
30 10 24V AC/DC 440R-S07283
110/230V AC 440R-S07284
  

When you order a combination Cat. No. You will receive a control unit, an NPN sensor and a PNP sensor.
440R-S07279 440R-S07139, 872C-D3NN12-E2, and 872C-D3NP12-E2
440R-S07280 440R-S07140, 872C-D3NN12-E2, and 872C-D3NP12-E2
440R-S07281 440R-S07139, 872C-D5NN18-E2, and 872C-D5NP18-E2
440R-S07282 440R-S07140, 872C-D5NN18-E2, and 872C-D5NP18-E2
440R-S07283 440R-S07139, 872C-D10NN30-E2, and 872C-D10NP30-E2
440R-S07284 440R-S07140, 872C-D10NN30-E2, and 872C-D10NP30-E2
  

Accessories

Description Power Supply Size (mm) Output Type Cat. No.
Control Unit Only 24V AC/DC 45 2 N.O. & 1 N.C. 440R-S07139
110/230V AC 2 N.O. & 1 N.C. 440R-S07140
Sensor Only 24V DC supplied by Control Unit 12 NPN 872C-D3NN12-E2
PNP 872C-D3NP12-E2
18 NPN 872C-D5NN18-E2
PNP 872C-D5NP18-E2
30 NPN 872C-D10NN30-E2
PNP 872C-D10NP30-E2
500 mA fuse—Bussmann Cat. No. ETF-500 mA 440R-A31562
 

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-S07279-84_Dim1

Block Diagram

Click to enlarge - 440R-S07279-84_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-S07279-84_Wiring01
Guard Locking Safety Gates, Motion Sensors, Delayed Gate Release, Automatic Reset, Monitored Output