The MSR22LM safety monitoring relay is designed to monitor light curtains with the added features of muting and presence sensing device initiation (PSDI). It provides an output to a machine control system when the light curtain is clear. When the inputs to the MSR22LM are closed (conducting), the output relays are closed if the monitoring circuit is satisfied.

The MSR22LM has three sets of dual channel inputs. This allows it to operate in four different configurations:


1. Monitors up to three light curtains in guard only mode.
2. Monitors up to two light curtains with two muting sensors (only one curtain muted).
3. Monitor one light curtain with four muting sensors.
4. Monitors up to three light curtains with PSDI (only one curtain initiated).

The MSR22LM uses microprocessor based technology to offer a wide variety of advanced safety solutions in a small 45 mm DIN rail mounted housing. Internal selector switches provide for easy selection of up to ten different applications. Four LEDs give operational status as well as diagnostic information. Removable terminals reduce wiring and installation costs when replacement is necessary.

Features


LED Indicators

Power: Green Ready
K1: Green K1 Closed
If K1 alone is lit, check for short across reset button
K2: Green K2 Closed
  

Specifications

Safety Ratings
Standards EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, IEC 61496-1, ANSI B11.19, AS4024.3
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
PFHD: < See website
MTTFd: > See website
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE marked for all applicable directives and BG
Power Supply
Input Power Entry 24V DC
Power Consumption 4 W
Inputs
Safety Inputs 2 N.C. Symmetric or Asymmetric, Switch Selectable
Input Simultaneity 0.5 seconds
Input Resistance, Max. S12-S14: 300 W
S21-S22: 200 W
S33-S34: 250 W
Reset Auto./Manual
Power On Delay Time 40 ms (Manual Reset); 200 ms (Auto Reset)
Response Time 15 ms
Outputs
Safety Contacts 2 N.O.
Auxiliary Contacts 1 N.C.
Thermal CurrentIlth 5 A nonswitching
Switching Current @ Voltage, Min. 1 mA/10V
Fuses, Output 6 A fast acting (external)
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 10,000,000 operations
Utilization Category (Inductive)
B500: AC-15 3 A @ 250V AC 3 A @ 120V AC
P300 DC-13 3 A/24V DC  
B300 AC-15 2 A @ 250V AC 2 A @ 120V AC
DC-13 2 A/24V DC  
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1), DIN 0470/
IP20, DIN 0470
Operating Temperature [C (F)] -15…55° (5…131°)
Vibration 0.35 mm 10…55 Hz
Mounting 35 mm DIN Rail
Weight [g (lbs)] 220 (0.485)
Conductor Size, Max. 1 x 2.5 mm2 (14 AWG) stranded, 1 x 4 mm2 (12 AWG) solid
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
3 x 2 N.C. 2 N.O. 1 N.C. Removable Auto./Manual 24V DC 440R-P23071
  

Accessories

Description Cat. No.
70 mm Tower Light Clear LED Module—Black Enclosure 855T-B24YL7
70 mm Tower Light Clear LED Module—Grey Enclosure 855T-G24YL7
  

Application Details

Click to enlarge - 440R-P23071_ApplicationDetail

Approximate Dimensions—mm (inches)

Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-P23071_Dim

Block Diagram

Click to enlarge - 440R-P23071_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-P23071_Wiring 01


Note: Two light curtains with two-sensor muting and Auto Restart LC1.

Click to enlarge - 440R-P23071_Wiring 02


Note: Typical one light curtain with four-sensor muting and Auto Restart LC1.

Click to enlarge - 440R-P23071_Wiring 03


Note: Light curtain inputs, Presence Sensing Device Initiation (on LC1) Start/Restart Interlock, Dual Channel Output, Output Monitoring.

Application Details

MSR22LM—Shown connected to a safety light curtain.

Multiple settings are available offering a variety of advantages. Below are the three most common settings.

Protective Mode

Example shows a press protected by a safety light curtain connected to the MSR22LM.


Click to enlarge - 440R-P23071_ApplicationDetail02


In machine operation, whenever the light curtain beams are broken the press immediately stops to help avoid danger to the operator. Once the beams are cleared the machine can then be started.

Muting Mode

Two examples are shown, both conveyor applications with a safety light curtain protecting the dangerous area. In-line and cross beam muting is used to allow the material to pass through the light curtain without stopping the machine. Any other object or person will be detected by the light curtain which will initiate machine stop.


Click to enlarge - 440R-P23071_ApplicationDetail03


In-line muting requires the material to break the beams in a sequence, as shown. Only if all four MS beams are broken in turn and then clear in turn will the light curtain allow material through without initiating machine stop.

Click to enlarge - 440R-P23071_ApplicationDetail04


Cross-beam muting requires the material to break the beams in a sequence. MS1 first and then MS2. Only if the beams are broken in turn and then clear in turn will the light curtain allow material through without initiating machine stop.

Auto Initiation Sequence (Stepping)—Double Break Shown

Auto initiation allows the machine to start and stop according to the number of times the light curtain beams are broken and cleared. Illustrated below is the MSR22LM set to auto initiation double break mode (after initial start-up sequence). Single- or three-break modes can also be selected.


Click to enlarge - 440R-P23071_ApplicationDetail05


First break—processed material removed

First clear—light curtain clear

Machine remains in stop mode


Click to enlarge - 440R-P23071_ApplicationDetail06


Second break—new material inserted

Machine remains in stop mode


Click to enlarge - 440R-P23071_ApplicationDetail07


Second clear—light curtain clear

Machine starts. Upon completion of cycle first break will start sequence again.