| Standards | EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, IEC 61496-1, ANSI B11.19, AS4024.3 | |
| Safety Classification | Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1 | |
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
PFHD: < See website MTTFd: > See website Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
|
| Certifications | CE marked for all applicable directives and BG | |
| Power Supply | ||
| Input Power Entry | 24V DC | |
| Power Consumption | 4 W | |
| Inputs | ||
| Safety Inputs | 2 N.C. Symmetric or Asymmetric, Switch Selectable | |
| Input Simultaneity | 0.5 seconds | |
| Input Resistance, Max. | S12-S14: 300 W S21-S22: 200 W S33-S34: 250 W |
|
| Reset | Auto./Manual | |
| Power On Delay Time | 40 ms (Manual Reset); 200 ms (Auto Reset) | |
| Response Time | 15 ms | |
| Outputs | ||
| Safety Contacts | 2 N.O. | |
| Auxiliary Contacts | 1 N.C. | |
| Thermal CurrentIlth | 5 A nonswitching | |
| Switching Current @ Voltage, Min. | 1 mA/10V | |
| Fuses, Output | 6 A fast acting (external) | |
| Electrical Life (Operations) | 220V AC/4 A/880VA cosf = 0.35…0.1 M 220V AC/1.7 A375VA cosf = 0.6…0.5 M 30V DC/2 A/60 W = 1 M 10V DC/0.01 A/0.1 W = 2 M |
|
| Mechanical Life | 10,000,000 operations | |
| Utilization Category (Inductive) | ||
| B500: AC-15 | 3 A @ 250V AC | 3 A @ 120V AC |
| P300 DC-13 | 3 A/24V DC | |
| B300 AC-15 | 2 A @ 250V AC | 2 A @ 120V AC |
| DC-13 | 2 A/24V DC | |
| Environmental and Physical Characteristics | ||
| Enclosure Type Rating/ Terminal Protection |
IP40 (NEMA 1), DIN 0470/ IP20, DIN 0470 |
|
| Operating Temperature [C (F)] | -15…55° (5…131°) | |
| Vibration | 0.35 mm 10…55 Hz | |
| Mounting | 35 mm DIN Rail | |
| Weight [g (lbs)] | 220 (0.485) | |
| Conductor Size, Max. | 1 x 2.5 mm2 (14 AWG) stranded, 1 x 4 mm2 (12 AWG) solid | |