Muting Light Curtain

Catalogs > Safety Products Catalog > Logic > Safety Relays > Specialty Safety Relays > Muting Light Curtain > MSR22LM

MSR22LM

Introduction Specifications Product Selection Accessories
Approximate Dimensions—mm (inches) Block Diagram Typical Wiring Diagrams Application Details
Specifications

Safety Ratings
Standards EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, IEC 61496-1, ANSI B11.19, AS4024.3
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
PFHD: < See website
MTTFd: > See website
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE marked for all applicable directives and BG
Power Supply
Input Power Entry 24V DC
Power Consumption 4 W
Inputs
Safety Inputs 2 N.C. Symmetric or Asymmetric, Switch Selectable
Input Simultaneity 0.5 seconds
Input Resistance, Max. S12-S14: 300 W
S21-S22: 200 W
S33-S34: 250 W
Reset Auto./Manual
Power On Delay Time 40 ms (Manual Reset); 200 ms (Auto Reset)
Response Time 15 ms
Outputs
Safety Contacts 2 N.O.
Auxiliary Contacts 1 N.C.
Thermal CurrentIlth 5 A nonswitching
Switching Current @ Voltage, Min. 1 mA/10V
Fuses, Output 6 A fast acting (external)
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 10,000,000 operations
Utilization Category (Inductive)
B500: AC-15 3 A @ 250V AC 3 A @ 120V AC
P300 DC-13 3 A/24V DC  
B300 AC-15 2 A @ 250V AC 2 A @ 120V AC
DC-13 2 A/24V DC  
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1), DIN 0470/
IP20, DIN 0470
Operating Temperature [C (F)] -15…55° (5…131°)
Vibration 0.35 mm 10…55 Hz
Mounting 35 mm DIN Rail
Weight [g (lbs)] 220 (0.485)
Conductor Size, Max. 1 x 2.5 mm2 (14 AWG) stranded, 1 x 4 mm2 (12 AWG) solid
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period