Catalogs > Safety Products Catalog > Logic > Safety Relays > Specialty Safety Relays > Muting Light Curtain > MSR22LM
MSR22LM
| Introduction | Specifications | Product Selection | Accessories |
| Approximate Dimensions—mm (inches) | Block Diagram | Typical Wiring Diagrams | Application Details |
MSR22LM—Shown connected to a safety light curtain.
Multiple settings are available offering a variety of advantages. Below are the three most common settings.
Protective Mode
Example shows a press protected by a safety light curtain connected to the MSR22LM.
|
In machine operation, whenever the light curtain beams are broken the press immediately stops to help avoid danger to the operator. Once the beams are cleared the machine can then be started.
Muting Mode
Two examples are shown, both conveyor applications with a safety light curtain protecting the dangerous area. In-line and cross beam muting is used to allow the material to pass through the light curtain without stopping the machine. Any other object or person will be detected by the light curtain which will initiate machine stop.
|
In-line muting requires the material to break the beams in a sequence, as shown. Only if all four MS beams are broken in turn and then clear in turn will the light curtain allow material through without initiating machine stop.
|
Cross-beam muting requires the material to break the beams in a sequence. MS1 first and then MS2. Only if the beams are broken in turn and then clear in turn will the light curtain allow material through without initiating machine stop.
Auto Initiation Sequence (Stepping)—Double Break Shown
Auto initiation allows the machine to start and stop according to the number of times the light curtain beams are broken and cleared. Illustrated below is the MSR22LM set to auto initiation double break mode (after initial start-up sequence). Single- or three-break modes can also be selected.
|
First break—processed material removed
First clear—light curtain clear
Machine remains in stop mode
|
Second break—new material inserted
Machine remains in stop mode
|
Second clear—light curtain clear
Machine starts. Upon completion of cycle first break will start sequence again.