Muting Light Curtain

Catalogs > Safety Products Catalog > Logic > Safety Relays > Specialty Safety Relays > Muting Light Curtain > MSR42

MSR42

Introduction Specifications Product Selection Approximate Dimensions
Accessories Typical Wiring Diagrams Application Details Wiring Diagram(s)
Two Sensor L-type

Click to enlarge - MSR42_2 sensor l-type


Uni-directional muting: This will allow material to exit the machine but not allow material or personnel to enter the machine without a fault condition. Only if both MS beams are broken in-turn and then cleared in-turn, will the light curtain allow material through without initiating a machine stop.

Two Sensor T-type with Enable

Click to enlarge - MSR42_2 sensor t-type w enable


Bi-directional muting: The MS3 is an input to the MSR42 from a PLC output card. The MS3 enables the muting function to be performed. If a high signal is not detected on MS3, the muting function will not operate even if the MS1 and MS2 beams are broken. Only if MS3 is high and both MS beams are broken in-turn and then cleared in-turn, will the light curtain allow material through without initiating a machine stop.