MatGuard™ Controllers
|
Description
The MatGuard Control Unit monitors all of the mats which are connected together to form a safeguarded zone. The safeguarded zone can be up to a total of 100 m2 and made from any number of mats. The controller is designed to interface with the control circuit of the machine and includes two safety relays to help provide control redundancy.
The controller detects a presence on the mat, a short circuit, or an open circuit. Under each of these conditions, the safety output relays turn off. When interfaced properly, the machine or hazardous motion will receive a stop signal, and an auxiliary output relay turns ON.
The controller comes in two different package styles, a plastic case for surface or wall mounting, and a steel case for surface or wall mounting. Each style offers many of the same basic features. Each controller accepts power supplies of 24V AC/DC, and 110/230V AC. The plastic and steel-cased styles include reset buttons. The steel-cased controller offers extra protection against inadvertent impacts.
Alternatively, see the Product Selection table for safety relays that can also control and monitor safety mats.
Features
- Selectable voltage supply
- Auto/manual reset
- Four-wire system to detect opens and shorts
- Third party approval—AMTRI, TÜV
LED Indicators
| Green | Power |
| Green | Auto Reset Mode |
| Green | Manual Reset Mode |
| Green | Machine Enabled |
Specifications
| Safety Ratings | |
| Standards | EN1760-1, EN 954-1, ISO13849-1, IEC/EN 60204-1, ANSI RIA R15.06, ANSI B11.19, AS 4024.5 |
| Safety Classification | Cat. 3 per EN 954-1 (ISO 13849-1), SIL CL2 per EN IEC 62061, PLe per ISO 13849-1 |
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/safety/ |
PFHD: See website MTTFd: See website Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics |
| Certifications | CE Marked for all applicable directives, cULus, and TÜV |
| Power Supply | |
| Input Power Entry | 24V AC/DC or 115/230V AC |
| Power Consumption | 6 W, 9V A |
| Inputs | |
| Safety Inputs | Safety Mats |
| Reset | Monitored Manual or Automatic/Manual |
| Response Time | 35 ms, Mat pressed to output open |
| Outputs | |
| Safety Contacts | 2 N.O. |
| Auxiliary Contacts | 1 N.C. |
| Switching Current @ Voltage, Min. | 10 mA @ 10V |
| Fuses, Output | 5 A fast acting (external) |
| Electrical Life (Operations) | 220V AC/4 A/880VA cosf = 0.35…0.1 M 220V AC/1.7 A375VA cosf = 0.6…0.5 M 30V DC/2 A/60 W = 1 M 10V DC/0.01 A/0.1 W = 2 M |
| Mechanical Life | 10,000,000 operations |
| Environmental and Physical Characteristics | |
| Enclosure Type Rating/ Terminal Protection |
4000P: IP65 (NEMA 13); 4000S: IP62 (NEMA 12)/ IP20, DIN 0470 |
| Operating Temperature [C (F)] | -10…+45 ° (14…113 °) |
| Vibration | 0.15 mm, 10…55 Hz |
| Mounting | Surface (Wall) Mount |
| Weight [g (lb)] | 4000P: 880 (1.94); 4000S: 3200 (7.05) |
| Conductor Size, Max. | 4000P, 4000S: 1 x 1.5 mm2 (16 AWG), max. |
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions: - Mission time/Proof test interval of 20 years - Functional test at least once within six-month period |
|
Product Selection
| Inputs | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. No. |
| SM | 2 N.O. | 1 N.C. | NA | Monitored Manual or Automatic/Manual | 24V AC/DC or 115/230V AC | 440F-C4000P |
| 440F-C4000S | ||||||
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|
|
| 440F-C4000P (Polycarbonate) | 440F-C4000S (Steel) |
Block Diagram
|
Typical Wiring Diagrams
|