MSR57P

Click to enlarge - 440R-S845AER-NNL_ (LEDs Lit)_Product_4C


Description

The MSR57P speed monitoring safety relay is designed to solve motion applications which require interaction by personnel during operation. It connects to any drive and monitors the speed using currently installed encoders. The MSR57P can be configured to unlock the access door only when the machine is either stopped or at a safe speed defined by the user. If required, the speed monitoring relay can monitor an enabling switch to constantly monitor personnel while in the hazardous area. Other supported functions are safe maximum speed and zero speed detection.

The MSR57P can be configured and monitored via two methods: drive explorer using a PC and the standard HIM device. During configuration, the user can set a variety of parameters to the specific requirements of their application including type of input devices, quantity, door locking and monitoring, enabling switches and a maintenance (safe speed) mode.

The MSR57P can easily be adapted to current installations with standard drives or drives with the safe-off feature. The safety relay uses standard outputs to control the drives speed but uses safety outputs to control the outputs of the drive. The speed is determined by using an encoder(s). This device can monitor the encoder data which is already transmitting to the drive, assuming an encoder is already installed, or a new encoder can be installed and only connected to the MSR57P. Two encoders are needed for Category 4, SIL 3 applications which cannot exclude shaft slippage and breakage.

This device also supports multiple axis applications. During configuration, it can be setup to be the first, middle or last axis in the chain. This is important since the input devices will all be installed on the first unit only while the output devices are connected to the last MSR57P in the chain.


Features


Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, ISOTR 12100, IEC/EN 60204-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: See website
MTTFd: See website
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications cULus, c-Tick, and TÜV
Power Supply
Input Power Entry 24V DC, 0.8…1.1 x rated voltage PELV/SELV
Power Consumption 5 W
Inputs
Safety Inputs 1 N.C. & 1 N.O., 2 N.C., 1 N.C., 2 OSSD
Input Simultaneity Infinite or 3 sec (configurable)
Input Resistance, Max. 4 K W
Reset Auto./Manual or Manual Monitored
Response Time Configurable
Outputs
Safety Contacts 6 N.O. Solid State
Auxiliary Contacts 4 N.O. solid state
Current, Max Outputs 14, 24, 68, 78 24V DC, 2 A, short‑circuit protected
Outputs 34, 44 24V DC, 100 mA, short‑circuit protected
Outputs Y35, Y37 24V DC, 50 mA, short‑circuit protected
Door switches 51, 52 24V DC, 750 mA, short‑circuit protected
Outputs Y1, Y32, Y33 24V DC, 100 mA, short‑circuit protected
Pulse Outputs S11, S21 24V DC, 100 mA, short‑circuit protected
Pulse Inputs S12, S22, S32, S42, S52, S62, S72, S82, X32, X42, S34, Y2 8.5 mA per input
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1)/
IP20, DIN 0470
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 335 (0.74)
Conductor Size, Max. 0.2…2.5 mm2 (24…12 AWG)
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
5 x 1 N.C., 2 N.C., LC, 1 N.O. + 1 N.C. 6 N.O. solid state 4 N.O. solid state Removable Auto./Manual or Manual Monitored 24V DC 440R-S845AER-NNL
  

Accessories

Description Cat. No.
MSR57 Encoder cable with flying leads (2.5 meters) 1585J-M8RB-2M5
3 meter cable HIM 1202-C30
1 meter cable HIM 1202-C10
AnaCANda serial converter (RS232) 1203-SSS
AnaCANda USB converter 1203-USB
HIM full numeric LCD IP20 (NEMA 1) 20-HIM-A3
Kinetix 6000/7000 low profile connector kit 2090-K6CK-Dxxx
Kinetix 2000 low profile connector kit 2090-K2CK-D15M
HIM to MSR 57 cable (1 meter) 20-HIM-H10
Sin/Cos encoder (1024 PPR) 842HR-xJxxx15FWY2
TTL encoder (size 20) 845T-xxxxxxx
TTL encoder (size 25) 845H-SJxxx4xxYxx
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - MSR57 Dimen


Block Diagram

Click to enlarge - MSR57 BlockDiagram

Typical Wiring Diagrams

Click to enlarge - MSR57 Wiring 1_4C


Note: Cat. 1 stop, 1 encoder, door monitoring, safe limited speed, PowerFlex 70 without safe off.

Click to enlarge - MSR57 Wiring 2_4C


Note: Cat. 1 stop, 1 encoder, door monitoring, enabling switch, safe limited speed, PowerFlex 70 with safe off.

Application Details

Click to enlarge - MSR57 AppDetails


Operating Conditions


Maintenance Conditions


Remarks