Operating Conditions
- The door is closed and locked with a TLS3 safety switch
- The machine is running at normal speed
Maintenance Conditions
- In order to remove a jam condition or during start-up personnel must enter the hazardous area.
- The operator moves Limited Speed Selector switch to enable.
- The MSR57 monitors speed profile and verifies drive is reducing speed per the preconfigured profile.
- Once the speed is equal to or below limited speed value, the door is unlocked.
- If configured, user must hold enabling switch in the middle position before opening door. Otherwise the machine will shutdown.
- The operator performs maintenance on the machine.
- Once maintenance is complete, the operator exits machine, closes door and moves the safe limited speed switch to "maintenance" mode BEFORE releasing the enabling switch.
- The machine will resume normal speed according to the drive profile.
Remarks
- The MSR57 can also monitor if the speed has exceeded a preconfigured value and shutdown the process.
- The MSR57 is compatible with all drives and uses standard inputs on the drive to perform controlled start and stop sequences.
- Pressing the E-stop at any time, will cause the machine to stop according to the preconfigured stop mode.
- The MSR57 can also be used in cascading applications with multiple MSR57s and drives.