CU1

Click to enlarge - 440R-E23159-195_Product

Description

The CU1 is an on-delay timing unit designed to energize and thus unlock guard locking devices after a preset time delay expires. It can be used with power to unlock devices, like the Allen-Bradley Guardmaster Atlas, Spartan, 440G-MT, or TLS-GD2, on machines which have a run down cycle or do not stop immediately. It may also be incorporated into other parts of the safety related controls system, should a predictable, on-delay be required.

A removable cover allows access to the AC power switch, the replaceable fuse, and the DIP switches & potentiometer which control the timing. Power to the CU1 can be either 24V AC/DC (+/- terminals) or 110/230V AC (A1/A2 terminals). If 110V AC or 230V AC power is used, an internal switch must be set to the appropriate position.

The X1/X2 terminals are designed to monitor the performance of the contactors which isolate the power to the moving parts of the machinery. The timing can not begin until the X1/X2 loop is closed. The X1/X2 loop must remain closed during the whole timing cycle. Opening the X1/ X2 loop during the timing cycle causes the time to be reset to zero. If monitoring is not needed, the X1/X2 loop can be linked.

A typical operation starts with the safety outputs (13/14 and 23/24) open and the X1/X2 loop closed.


1. Apply power to A1/A2 or +/-.
  a. The Power LED turns ON and the Output LED turns red.
  b. After the time delay expires, the Output LED turns green and the safety outputs (13/14 and 23/24) close.
2. Remove power to A1/A2 or +/-.
  a. Immediately, the safety contacts (13/14 and 23/24) open, the Power LED turns off and the Output LED turns Off.
3. Go to step 1.

The status of the CU1 can be signaled to the Remote Indicator Unit via terminals R1/R2/R3, or to a PLC or other indicator by using the N.C. auxiliary contacts (31/32).

Features


Specifications

Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1
Category Cat. 1 per EN 954-1 (ISO13849-1)
Certifications
Power Supply 24V AC/DC, 115V AC, or 230V AC
Power Consumption <4 VA
Safety Inputs 1 N.O.
Input Resistance, Max. 500 W
Reset Type Automatic/Manual
Safety Outputs Delayed—3 N.O. Safety
Delayed—2 N.C. Auxiliary
Output Utilization per IEC60947-5-1 (Inductive)¬  B300, AC-15: 4 A/250V AC, 4 A/125V AC
P300, DC-13: 3 A/24V DC
Thermal Current 2 x 4 A, nonswitching
Time Range (Off-Delay) 0.1s…40 min.
Fuses, Input 500 mA time lag (external)
Fuses, Output 5 A quick acting (external)
Switching Current @ Voltage, Max. 10 mA/10V
Status Indicators Red = Power on
Red/Green = Timing/Output on
Rated Impulse withstand Voltage 2500V
Operating Temperature [C (F)] -10…55° (14…131°)
Relative humidity 90%
Enclosure Type Rating IP40, DIN 0470
Terminal Protection IP20 DIN 0470
Conductor Size, Max. 1 x 2.5 mm2 (14 AWG) stranded
1 x 4 mm2 (12 AWG) solid
Installation Group C in accordance with VDE 0110
Pollution Degree 3
Torque Settingste—terminal screws 1 N•m (8 lb•in)
Housing Material Red Polycarbonate
Mounting 35 mm DIN Rail
Weight [g (lb)] 360 (0.79)
Electrical Life 220V AC/4A/880VA cosf = 3.5—100,000 operations
220V AC/1.7A/375VA cosf = 0.6—500,000 operations
30V DC/2A/60W—1,000,000 operations
10V DC/0.01A/0.1W—2,000,000 operations
Mechanical Life 2,000,000 operations
Vibration 0.75 mm (0.30 in) peak, 10…55 Hz
Shock 30 g, 11 ms half-sine
  
¬ See Output Ratings see Output Ratings for details. Consult factory for ratings not shown.

Product Selection

Inputs Safety Outputs Auxiliary Outputs Power Supply Cat. No.
1 or 2 N.O., 1 or 2 N.C., LC, 2 hand control, enabling switch Delayed—3 N.O. Delayed—2 N.C. 24V AC/DC, 115V AC, or 230V AC 440R-T07114
  

Accessories

Description Page Number Cat. No.
500 mA fuse—Bussmann Cat. No. ETF-500 mA   440R-A31562
CU1 Remote Indication Unit 440R-A07138
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-T07114_Dim

Block Diagram

Click to enlarge - 440R-T07114_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-T07114_Wiring 01
Guard Locking Safety Gate, Delayed Gate Release, Automatic Reset, Monitored Output

Application Details

Click to enlarge - 440R-T07114_ApplicationDetail Click to enlarge - 440R-T07114_ApplicationDetail02
DIP switches general time setting and the
potentiometer fine tunes the time settings.
Easy access 500mAT replaceable fuse.