MSR211P

Click to enlarge - 440R-H23177_Product


Description

The MSR211P forms one of the base units for the modular Minotaur MSR200 family of monitoring safety relays. It can be combined with other modules of the MSR200 Series to configure a safety control system with numbers of inputs and outputs matching users’ specific application requirements, as well as diagnostic and networking capabilities. Up to ten input modules and two output modules can be connected to one base unit by simply removing the terminator, included with each base unit, and connecting the ribbon cables of the neighboring module. The terminators must be inserted into the final input and output modules.

The MSR211P has two inputs. Each input can be wired in one of three ways: one normally closed, two normally closed, or two OSSD connections from a light curtain. The MSR211P does not perform cross fault monitoring, and would not detect a short across the inputs of a two normally closed input. When connected to light curtains, the light curtain must perform the cross fault detection.

The MSR211P has the capability to perform external device monitoring (EDM). The EDM capability works in conjunction with the reset option. The user selects EDM and the reset function by jumpers across terminals Y40, Y41 and Y42.

The MSR211P has two semiconductor outputs designed to send status information to a PLC. Terminal Y33 indicates the inputs are closed (the ready LED is on). Terminal Y32 indicates the outputs are active.

The outputs include two normally open safety rated outputs and one normally closed auxiliary output.


Features


LED Indicators

Green Input 1 Closed
Red Input 1 Open
Green Input 2 Closed
Red Input 2 Open
Green CH1 Output Active
Green CH2 Output Active
Green Power
Green Run (Outputs Active)
Red Stop (Outputs Off) + Diagnostics
Amber Ready (Inputs Closed)
  

Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI 11.19, AS 4024.1
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 3.49 x 10-9
MTTFd: > 188 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and TÜV
Power Supply
Input Power Entry 24V DC 0.8…1.1 x rated voltage
Power Consumption 8 W
Inputs
Safety Inputs Two Inputs 1 N.C. or 2 N.C. or LC
Input Simultaneity Infinite
Input Resistance, Max. Inputs: 900 W
Reset: 3200 W
Reset Auto./Manual or Monitored Manual
Power On Delay/
Recovery Time
3 seconds/40…145 ms, depending on expansion modules used
Response Time MSR211: 25 ms
MSR211+ MSR221.: 30 ms+2.4 ms per MSR221
Outputs
Safety Contacts 2 N.O.
Auxiliary Contacts 1 N.C., 2 PNP
Thermal CurrentIlth 1 x 6 A or 2 x 4 A (nonswitching)
Rated Impulse withstand VoltageIlth 2500V
Switching Current @ Voltage, Min. 10 mA @ 10V DC
Fuses, Output External 6 A slow blow or 10 A quick blow
Solid State Output Rating 20 mA @ 30V DC short-circuit protection
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 cycles
Utilization Category
Resistive: AC-1 6 A @ 250V AC  
Resistive: DC-1 6 A @ 24V DC  
Inductive: AC-15 3 A @ 250V AC B300 3 A @ 125V AC
Inductive: DC-13 2.5 A @ 24V DC  
UL 1 x B300, R300 or 2 x C300 1 x 6 A or 2 x 4 A Resistive
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1)/
IP20
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 280 (0.62)
Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Inputs Safety Outputs Auxiliary Outputs Solid State Outputs Terminals Reset Type Power Supply Cat. No.
Two independent inputs; 2 x 1 N.C., 2 N.C., or Light Curtain 2 N.O. 1 N.C. 2 PNP Removable Auto./Manual or Monitored Manual 24V DC from the base unit 440R-H23177
  

Accessories

Description Cat. No.
MSR200, Two Terminators 440R-A17138
Bag of 4, 4-Pin Screw Terminal Blocks 440R-A23209
Bag of 4, 4-Pin Spring Clamp Terminal Blocks 440R-A23228
  

Diagnostics—Red Stop LED Blinks

Blink Rate Description
2 Change in Y40/Y41/Y42 circuit during operation.
3 Fault in external feedback circuit Y1-Y2. Clear fault and cycle power to reset the module.
Continuous Internal fault in base or expansion module.
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-H23177_Dim

Block Diagram

Click to enlarge - 440R-H23177_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-H23177_Wiring 01      Click to enlarge - 440R-H23177_Wiring 02
 
Light Curtain and Dual Channel Safety Gate,
Monitored Manual Reset, Monitored Output
     Light Curtain and Dual Channel Safety Gate,
Monitored Manual Reset, No Monitored Output
 
Click to enlarge - 440R-H23177_Wiring 03        
 
Two Light Curtains,
Automatic Reset, Monitored Output